§ 10-92 — Amendments to the adopted chapters of the International Energy Conservation Code(2021)
San Antonio City Code (Supp. No. 147: codified through Ordinance No. 2026-09-10-547, adopted Sept. 10, 2026) · San Antonio City Code § 10-92
Corpus is an independent public-information project, not the official City of San Antonio website. Stable reference: corpuslaw.us/code/84e135fc-7e85-47b3-ac3a-f81019651d83
Sec. 10-92. - Amendments to the adopted chapters of the International Energy Conservation Code(2021).
Additions to the International Energy Conservation Code (IECC) are shown as underlined text. Deletions of the IECC are shown as bracketed [strikethroughs]. Section C402.3, Roof solar reflectance and thermal emittance, is amended to read as follows (exceptions are unchanged): C402.3 Roof solar reflectance and thermal emittance. Low-sloped roofs, with a slope less than or equal to 2 units vertical per 12 units horizontal, directly above cooled conditioned spaces in Climate Zones 0 through 3 shall comply with one or more of the options in Table C402.3. Roof surfaces with a slope greater than 2 units vertical per 12 units horizontal, directly above cooled conditioned spaces shall have a minimum reflectance of 0.35 or a minimum Solar Reflective Index of 29. Section C402.4.2, Minimum skylight fenestration area, Exception is amended by adding a sixth exception as follows. All other language in Section C402.4.2 remains: Exception: Skylights above daylight zones of enclosed spaces are not required in: 1. Buildings in Climate Zones 6 through 8. 2. Spaces where the designed general lighting power densities are less than 0.5 W/ft 2 (5.4 W/m 2 ). 3. Areas where it is documented that existing structures or natural objects block direct beam sunlight on not less than half of the roof over the enclosed area for more than 1,500 daytime hours per year between 8 a.m. and 4 p.m. 4. Spaces where the daylight zone under rooftop monitors is greater than 50 percent of the enclosed space floor area. 5. Spaces where the total area minus the area of sidelit daylight zones is less than 2,500 square feet (232 m 2 ), and where the lighting is controlled in accordance with Section C405.2.3. 6. Spaces designed as storm shelters complying with ICC 500. 7. In warehouses protected by Early Suppression Fast Response (ESFR) fire sprinklers where vertical wall fenestration is provided with a minimum areas equal to that determined by Section C402.4.2. Section C404.6.1, Circulation systems, is amended to read as follows: C404.6.1 Circulation systems. Heated-water circulation systems shall be provided with a circulation pump. The system return pipe shall be a dedicated return pipe or a cold-water supply pipe. Gravity and thermo-syphon circulation systems shall be prohibited. Controls for circulating hot water system pumps shall automatically turn off the pump when the water in circulation loop is at the desired temperature and when there is not a demand for hot water. The controls shall limit the temperature of the water entering the cold-water piping to not greater than 104°F (40°C) and shall comply with one of the following: 1. Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for hot water within the occupancy. The controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and when there is not a demand for hot water. 2. Controls for circulating hot water system pumps shall include a timer clock switch operating pumps based on time of day/night. Controls shall also include a return water temperature sensor switch to pause the re-circulating pump whenever the return water is hot. Section C405.6, Dwelling electrical meter, is modified to read as follows: C405.6 Dwelling electrical meter. Each dwelling unit located in a Group R-2 multi-family building shall have a separate electrical meter. Section C405.12, Energy monitoring, is modified to read as follows with remaining text to remain as written: C405.12 Energy monitoring. New buildings with a gross conditioned floor area of [25,000] 100,000 square feet or larger shall be equipped to measure, monitor, record and report energy consumption data in compliance with Sections C405.12.1 through C405.12.5 Exception: R-2 occupancies and individual tenant spaces in other occupancies are not required to comply with this section provided that the space has its own utility services ad meters and has less than [5,000] 10,000 square feet of conditioned floor area. SECTION C409, ELECTRIC VEHICLE (EV) CAPABLE, and Section C409.1, Electric vehicle power supply, and Section C409.2, Number of parking spaces, are added as follows: SECTION C409 ELECTRIC VEHICLE (EV) CAPABLE This section applies to all buildings not included in SECTION R410. C409.1 Electric vehicle power supply. The main electrical service panel shall have the capacity to support the required number of spaces detailed in C409.2. The property owner will designate which branch panel(s) will be utilized for future EV charging. The designated branch panel(s) shall reserve the space and capacity to support one future 40-ampere breaker for every 2 spaces required. The designated breaker spaces may be located in multiple branch panels as long as the total number space and capacity is met. The reserved space(s) in the designated branch panel(s) shall be labeled "For Future EV". The Director may increase the number of spaces per 40-ampere breaker or lower the breaker's ampere size as smart charging technology is developed. C409.2 Number of parking spaces. The reserved capacity shall be capable to support 5% of the total required parking spaces. Section C501.5, Historic buildings, is amended to read as follows: C501.5 Historic buildings. Provisions of this code relating to the construction, repair, alteration, restoration, and movement of structures, and change of occupancy shall not be mandatory for historic buildings. [provided a report has been submitted to the code official and signed by a registered design professional or a representative of the State Historic Preservation Office or the historic preservation authority having jurisdiction, demonstrating that compliance with that provision would threaten, degrade, or destroy the historic form, fabric, or function of the building.] Section C503.2.1, Roof replacement, is amended to read as follows: C503.2.1 Roof replacement. Roof replacements shall comply with Section C402.1.3, C402.1.4, C402.1.5 or C407 where the existing roof assembly is part of the building thermal envelope and contains insulation entirely above the roof deck. In no case shall the R-value of the roof insulation re reduced or the U-Factor of the roof assembly be increased as part of the roof replacement. New skylights are not required to be provided as part of a roof replacement where the existing building did not have skylights. Where new skylights are installed at the option of the owner as part of the roof replacement, they shall meet Section C503.2.3. Table R402.1.3, INSULATION MINIMUM R-VALUES AND FENESTRATION REQUIREMENTS BY COMPONENT, is amended as follows with all other text in the table to remain as is: Climate Zone | Fenestration U-Factor | Skylight U-Factor | Glazed Fenestration SHGC | Ceiling R-Value | Wood Frame Wall R-Value | Mass Wall R-Value | Floor R-Value | Basement Wall R-Value | Slab R-Value & Depth | Crawl Space Wall R-Value 2 | 0.40 | 0.65 | 0.25 | [49] 38 | 13 or 0&10ci | 4/6 | 13 | 0 | 0 | 0 Section R402.4.1.1, Installation, is amended to read as follows: R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria indicated in Table R402.4.1.1, as applicable to the method of construction. [Where required by the code official, an] An approved third party shall inspect all components and verify compliance. Insulation letters shall not be submitted to the Building Official prior to the inspection being performed and shall be submitted on a form approved by the Building Official. Section R402.4.1.2, Testing, is amended by amending the first paragraph to read as follows. All other language in Section R402.4.1.2 remains: R402.4.1.2 Testing. The building or dwelling unit shall be tested for air leakage. The maximum air leakage rate for any building or dwelling unit under any compliance path shall not exceed 5.0 air changes per hour or 0.28 cubic feet per minute (CFM) per square foot [0.0079m 3 /(s × m 2 )] of dwelling unit enclosure area. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380, ASTM E 779 or ASTM E 1827 and reported at a pressure of 0.2-inch w.g. (50 Pascals). [Where required by the code official, testing] Testing shall be conducted by an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the Building Official [code official]. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope have been sealed. Section R402.4.6, Electrical and communication outlet boxes (air-sealed boxes), is amended as follows. R402.4.6 Electrical and communication outlet boxes (air-sealed boxes). Electrical and communication outlet boxes installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces [. Electrical and communication] or outlet boxes shall be tested in accordance with NEMA OS 4, Requirements for Air-Sealed Boxes for Electrical and Communication Applications and shall have an air leakage rate of not greater than 2.0 cubic feet per minute (0.944 L/s) at a pressure differential of 1.57 psf (75 Pa). Electrical and communication outlet boxes shall be marked "NEMA OS 4" or "OS 4" in accordance with NEMA OS 4. Electrical and communication outlet boxes shall be installed per the manufacturer's instructions and with any supplied components required to achieve compliance with NEMA OS 4. Section R402.6, Radiant Barrier, is added to read as follows: R402.6 Radiant Barrier. In new dwellings, a roof radiant barrier with an emittance of 0.10 or less as tested in accordance with ASTM C-1371 or ASTM E-408 is required above conditioned spaces. The radiant barrier shall be installed according to the manufacturer's instructions. Exceptions: 1. Roofs covered with materials that have a solar reflectance of 0.4 or greater. 2. Residential buildings with sealed attics such as foam type insulation or similar. 3. Residential buildings with all mechanical equipment and all ductwork located wholly within the conditioned space. R403.3.1, Ducts located outside conditioned space, is amended by adding an exception as follows. R403.3.1 Ducts located outside conditioned space. Supply and return ducts located outside conditioned space shall be insulated to an R-value of not less than R-8 for ducts 3 inches (76 mm) in diameter and larger and not less than R-6 for ducts smaller than 3 inches (76 mm) in diameter. Ducts buried beneath a building shall be insulated as required per this section or have an equivalent thermal distribution efficiency. Underground ducts utilizing the thermal distribution efficiency method shall be listed and labeled to indicate the R-value equivalency. Exception: 1. Supply and return ducts in attics shall be insulated to an R-value of not less than R-6 for ducts 3 inches (76 mm) in diameter and larger, where the efficiency of the installed cooling equipment is higher than the minimum required by federal law for climate zone 2. Section R403.5.1.1, Circulation systems, is amended to read as follows: R403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump. The system return pipe shall be a dedicated return pipe or a cold-water supply pipe. Gravity and thermosyphon circulation systems shall be prohibited. Controls for circulating hot water system pumps shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and when there is no demand for hot water. The controls shall limit the temperature of the water entering the cold-water piping to not greater than 104°F (40°C) and shall comply with one of the following: 1. Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for hot water within the occupancy. The controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and when there is no demand for hot water. 2. Controls for circulating hot water system pumps shall include a timer clock switch operating pumps based on time of day/night. Controls shall also include a return water temperature sensor switch to pause the re-circulating pump whenever the return water is hot. Section R403.6.3, Testing, is repealed in its entirety. Section R404, ELECTRICAL POWER AND LIGHTING SYSTEMS, is repealed in its entirety. Table R406.5, Maximum energy Rating Index, is amended as follows: TABLE R406.5 MAXIMUM ENERGY RATING INDEX CLIMATE ZONE | ENERGY RATING INDEX 0-1 | 52 2 | 59 [52] 3 | 51 4 | 54 5 | 55 6 | 54 7 | 53 8 | 53 SECTION R409, PHOTOVOLTAIC (PV) CAPABLE, and Section R409.1, Electrical service reserved space, are added as follows: SECTION R409 PHOTOVOLTAIC (PV) CAPABLE This section applies to detached one- and two- family dwellings and townhouses three stories or less in height above grade plane. R409.1 Electrical service reserve space. The main electrical service panel shall have a reserved space to allow installation of a dual pole circuit breaker for future solar electric installation and shall be labeled "For Future Solar Electric." The reserved space shall be positioned at the opposite (load) end from the input feeder location or main circuit location. SECTION R410, ELECTRIC VEHICLE (EV) READY, and Section R410.1, Electric vehicle ready, are added as follows: SECTION R410 ELECTRIC VEHICLE (EV) READY This section applies to detached one- and two-family dwellings and townhouses three stories or less in height above grade plane. R410.1 Electric vehicle ready. One- and two- family dwellings, townhouses three stories or less with a garage shall have a dedicated 40amp/240volt single receptacle for EV use. Exception: Properties without a garage. Section R501.6, Historic buildings, is amended to read as follows: R501.6 Historic buildings. Provisions of this code relating to the construction, repair, alteration, restoration, and movement of structures, and change of occupancy shall not be mandatory for historic buildings. [provided that a report has been submitted to the code official and signed by the owner, a registered design professional, or a representative of the State Historic Preservation Office or the historic preservation authority having jurisdiction, demonstrating that compliance with that provision would threaten, degrade, or destroy the historic form, fabric, or function of the building.]
(Ord. No. 2025-01-30-0075, § 1(Att. 1), 1-30-25)
Ask a question about San Antonio law
Corpus searches the San Antonio sections it holds and shows the ones that match, with their citations. Free, no sign-in.