503.2.1 Dimensions.
Cedar Rapids Municipal Code § 37.14
in effect37.14 - 503.2.1 Dimensions.
Section 503.2.1 entitled "Dimensions" is hereby modified by replacing the words "20 feet" with the words "28 feet" and adding three exceptions as follows:
Section 503.2.1 Dimensions. Fire apparatus access roads shall have an unobstructed width of not less than 28 feet, exclusive of shoulders, except for approved security gates in accordance with Section 503.6, and an unobstructed vertical clearance of not less than 13 feet 6 inches.
Exceptions:
1. Fire apparatus access road width may be reduced to 24 feet of level unobstructed width when such access roads meet the definition of a Private Street as set forth in Chapter 31 of the Municipal Code of the City of Cedar Rapids subsection 31.03 (d) 2 Private Streets.
2. The width may be reduced when access roads will be exclusively used for fire apparatus and when approved by the fire code official.
3. Upon approval of the fire code official, vertical clearance may be reduced, provided such clearance does not impair access by fire apparatus, and approved signs are installed and maintained indicating the established vertical unobstructed clearance.
(039-24)
Source: City of Cedar Rapids, Iowa, Municipal Code and Charter (Municode Library, library.municode.com)URL: https://library.municode.com/ia/cedar_rapids/codes/code_of_ordinances?nodeId=xA252BF08A062Fetched: 11/8/2026