§ 49-1530 — Equivalent fixture units
Omaha Municipal Code (Supp. No. 100, Update 2: codified through Ordinance No. 44760, enacted August 4, 2026) · Omaha Municipal Code § 49-1530
Corpus is an independent public-information project, not the official City of Omaha website. Stable reference: corpuslaw.us/code/8675147a-6314-405e-aa64-bc897bcc9d46
Sec. 49-1530. - Equivalent fixture units.
Equivalent fixture units shall be as provided in the following table: If a fixture is not listed in the assembly column then the public column shall apply. Table 49-1530 (Includes combined hot and cold water demand.) Fixture Units Minimum Connection Kind of Fixture | Fixture Units Private | Public | Assembly Bathroom group (flush tank For WC) (Note 4) | 3 | 4 | 6 Bathroom group (flushometer valve for WC) (Note 4) | 10 | 10 Restroom group (flush tank For WC) (Note 4) | 3 | 4 | 6 Restroom group (flushometer valve For WC) (Note 4) | 10 | 10 Restroom unisex (flush tank for WC (including Urinal)) | 5 | 5 Restroom unisex (flushometer for WC (including urinal) (Note 4) | 10 | 10 Bar sink: Residential | 1 Commercial (three and four well sinks) | 6 | 6 Bathtub (with or without shower over) | 2 | 2 Bidets | 2 | 2 Cuspidors | 1 Disposal | N/R | 6 Drinking fountain | 0.5 | 0.5 | 1 Dishwasher (see Note 1) | 2 | 2 Flushing rim sink | 6 Glass washer | 2 Hose bib or sill cock (standard type) | 3 | 5 Laundry sink | 2 | 4 Lawn sprinkler (see Note 2) Lavatory (basin) | 1 | 1 | 2 Mop sink | 3 Pedicure foot bath | 2 Restroom (single use i.e. unisex/family use) Service sinks | 3 | 3 Shower (each head) | 2 | 2 | 2 Shower (with more than 3 heads plus 1 FU for each additional head) | 10 | 10 | 10 Sink—Residential (see Note 1) | 2 | 2 Sink—Commercial three-compartment | 6 | 6 Sink—Commercial single well pot | 6 | 6 Sitz bath | 2 | 4 Shampoo sink | 2 Urinals: Floor urinal | 5 Pedestal urinals | 10 Blowout | 10 Wash down | 5 With flush tank | 3 Wash fountains: Circular | 4 Multiple faucet (each set of faucets) | 2 Washers, clothes (each pair of faucets) | 2 | 2 Washers, clothes, commercial (Note 1) Water closet: Flush tank | 3 | 5 Flush valve | 10 | 10 Whirlpool bathtubs (Note 3) | 4 | 4 Water supply outlets for items not listed above shall be sized at their maximum demand, but in no case less than the following: Fixture Units Private | Public ⅜-inch | 1 | 2 ½-inch | 2 | 4 ¾-inch | 3 | 6 1-inch | 6 | 10 Note 1: Commercial clothes washers, if connected directly by means of rigid piping, shall be assigned a fixture unit value based upon the machine's inlet size or the gallons per cycle, whichever is greater. Note 2: See article XIX, Lawn Sprinkler Systems, for sizing requirements. When sizing a system for dwelling units and townhouses, which includes a lawn sprinkling system, sill cocks may be excluded. When a system includes multiple sill cocks, only 50 percent need be included in the sizing calculation. Note 3: All whirlpool bathtubs with a manufacturer rating of 40 gallons or more. Note 4: Fixture Groups will be assigned fixture units as follows for the purpose of this section: Bathroom group (flush tank for WC): One WC with a flush tank, one lavatory and one tub or shower. Bathroom group (flushometer valve for WC): One WC with a flush valve, one lavatory and one tub or shower. Restroom group (flush tank for WC): One WC with a flush tank and one lavatory. Restroom group (flushometer valve for WC): One WC with a flush valve and one lavatory. Unisex (flush tank for WC including urinal): One WC with flush tank, one lavatory and one urinal. Unisex (flushometer for WC including urinal): One WC with flush valve, one lavatory and one urinal. The fixture water supply pipe shall be extended to within 30 inches of the point of connection to the fixture.
(Ord. No. 40524, § 1, 10-20-15; Ord. No. 42654, § 47, 8-13-21)
Ask a question about Omaha law
Corpus searches the Omaha sections it holds and shows the ones that match, with their citations. Free, no sign-in.