§ 34.02 — WORK PERMITS
Madison General Ordinances (Rev. 28, Update 3: codified through ORD-26-00040, published August 3, 2026) · Madison General Ordinances § 34.02
Corpus is an independent public-information project, not the official City of Madison website. Stable reference: corpuslaw.us/code/867e90a4-be00-45b2-a8df-41cbe1669d7b
34.02 - WORK PERMITS.
(1) Work Permit Required. (a) A Work Permit is required to install, erect, construct, add to, enlarge, move, improve, alter, convert, extend, replace components, or demolish or cause the same to be done, or commence any work covered by this code. 1. A Work Permit must be obtained prior to commencing any such work on any of the following: a. Fire protection and Life Safety systems (IFC Chapter 9): i. Exceptions: Fire extinguishers (IFC 906), single- and multi-station smoke alarms (IFC 907.2.11), carbon monoxide detection (IFC 915). b. Electronic locks access control, delayed egress, stair door locking system or device (IFC Chapter 10). c. LPG containers (IFC Chapter 61). d. High-piled storage arrays (IFC Chapter 32). e. Closure, change in use or temporary removal of any (above ground) tank system (in excess of sixty (60) gallons and less than five thousand (5,000) gallons) not regulated by SPS 310. 2. Work may begin on fire protection systems found to be out of service or otherwise not functioning immediately; with an email notification to [email protected] with contractor information, address of work to be completed, and description of work. A work permit shall be submitted within three (3) days. 3. The issuance or granting of a permit and approval of plans or specifications shall not be deemed or construed to be a permit for, or an approval of, any violation of any of the provisions of this code. 4. The issuance or granting of a permit and approval of plans or specifications shall not be deemed or construed to be a permit for, or an approval of, any violation of any of the provisions of this code. 5. A Work Permit is not required for repairs and component replacement. 6. The Chief may require a Work Permit or design documents for systems, projects or fire and life safety aspects associated with the use and occupancy of building and premises that fall in the scope of this code. (b) Definitions. In this subsection, the following terms mean: Administrative Hold. Occurs when there is incomplete or inaccurate application for a Work Permit. Generally, a hold can be released upon the receipt of additional information. New Systems. To construct, erect, add to, extend or install a system regulated by this code. Denial of Approval. To return the application or plans to the applicant when said application or plans do not demonstrate substantial compliance with the applicable code. Denial of Approval requires submittal of a new application, plans, specifications and fees. Plan Revision. For the Chief to require and the applicant to provide design changes during the application review process or correction of errors in the application. For the applicant to resubmit previously approved plans due to design changes. Repair or Component Replacement. To repair or replace components or devices associated with a system regulated by this code. A repair is limited to "like for like" devices with no design impact. Replacement is defined as installing the same make and same model component in the same location as the device being replaced. System Modification. To alter, modify, upgrade, improve or convert an existing system regulated by this code. Any work on an existing system that impacts or changes the system design, coverage area, occupancy, design criteria, system performance or listing. Examples include, but are not limited to: replacing a fire alarm control panel, switching from analog to digital technology, replacing components with different flow characteristics, changing the system capacity. (c) State-owned Buildings. 1. A Work Permit is required for state-owned projects. 2. When plans are approved by a state agency, a copy of the state plan approval letter is required as part of the permit application. 3. When plans are reviewed by the Chief, a complete submittal to include application, plans and fees is required. 4. The Chief shall inspect the fire protection systems in state owned buildings. See Sec. 34.02(2)(d) for the applicable inspection fee. (Am. by ORD-22-00122, 12-3-22) (d) Duties of the Applicant. 1. Applications for permits shall be filed with the Chief in writing on a form furnished by the Chief. Applications shall be completed in details and all fields must be completed. 2. The applicant shall provide a detailed description of the work which will identify the proposed installation or work and shall detail the use or occupancy of all parts of the building and such other pertinent information. 3. The applicant shall submit three (3) sets of working plans and one (1) set of specifications or supporting documents with the application. 4. By filing, the applicant certifies the installation will comply with the applicable codes. 5. Submit fee in accordance with Sec. 34.02(2). 6. When advised of an administrative hold, the applicant shall submit the requested application materials within fifteen (15) days of being notified. If said requested materials are not received within fifteen (15) days the application will be rejected. 7. When plan revisions are required by the Chief, the applicant shall submit the revised application or plan revision documents within fifteen (15) days. If said requested materials are not received within fifteen (15) days the application will be rejected. (e) Design Documents. 1. New systems and system modifications require design documents. 2. Working plans and specifications showing the location of each component or element of the proposed system, all drawings, manufacturers cut sheets for devices, calculations, material approvals, manufacturers listed installation and design manuals, pre-engineered design specifications, design specifications, and the manufacturer, model and type of each component element of such systems, when needed, shall accompany every application for a permit, and shall be filed with the application. Exceptions: a. The Chief may authorize the issuance of a permit without plans or specifications for minor or inconsequential work. b. Alterations to or modifications of an existing system may not, at the discretion of the Chief, require a complete set of plans as set forth above, however, each such application for a permit shall include appropriate supporting documentation establishing that the proposed alterations or modifications comply with all appropriate codes, ordinances and standards. c. Systems modification involving twenty or less fire sprinklers. d. Systems modification involving three or less fire alarm devices, not to include a fire alarm control panel. 3. Plans submitted shall be drawn to scale and be clearly legible. The submitted plans shall be of sufficient clarity to indicate the nature and character of the work proposed and to show that the applicable regulations will be complied with. Plans shall accurately reflect the proposed installation. They shall be prepared in accordance with the provisions of this code, and shall bear the name of the architect, professional engineer, contractor or other person who prepared them. 4. Specifications shall be in detail. Any specifications in which general expressions are used to the effect that "work shall be done in accordance with the Fire Code" or "to the satisfaction of the Fire Chief" shall be deemed imperfect and incomplete. Every reference to the Fire code shall be to the section or subsection applicable. 5. The data specified in all applicable standards adopted by this code shall be a part of, or shall accompany, all plans submitted for approval. 6. Plan revisions shall specify and identify all changes. 7. Applications for the removal of a fire protection system shall include a code analysis documenting the system is not a required system. (f) Duties of the Chief. 1. Permits shall be issued in the name of the, applicant, owner or owner's agent 2. The Chief shall provide an application form for a work permit. 3. If the application, plans and specifications are in conformity with the requirements of this code and all other laws or ordinances applicable thereto, the Chief shall, upon receipt of the required fee, grant a work permit for said work and shall sign, date and endorse all sets of submitted plans as approved or if approval is conditioned upon changes to the plan or compliance with other conditions, the plans may be conditionally approved. In all such cases where plans are conditionally approved the Chief shall return, with the plans, written notification of the conditions that must be satisfied. 4. If, subsequent to the issuance of a permit, errors are discovered in the application, plans, specifications or execution of the work, the Chief may require the correction of said errors in said application, plans, specifications or construction and may rescind the permit and prevent installation and work operations from continuing when in violation of this code or of any ordinance. 5. Whenever a submitted application is incomplete, the Chief may place an administrative hold and suspend any action on such application and shall notify the applicant of the information needed to process such application. 6. When the application or plans fail to demonstrate substantial compliance with the applicable codes, the Chief may deny approval of the application and notify the applicant. 7. The Chief may require plan revisions of specific application and plan documents when additional or alternate information is required to demonstrate substantial compliance with the applicable standards. 8. The appropriate portion of each fee, as set forth in Wis. Admin. Code § SPS 302.31, Table 2.31-3, shall be forwarded to Department of Safety and Professional Services. (g) Execution of Permitted Work. 1. Work covered by a Work Permit shall not commence until a Work Permit is obtained. 2. The work shall be installed as shown on the plans and there shall be no modifications or alterations made without written permission from the Chief. 3. Except as authorized by the Chief all portions of any system that are to be concealed must be tested by the installing contractor and be approved by the Chief before concealment. (h) Time Limitation of Work Permit. 1. Permits issued under this code shall lapse and be void unless: a. The work authorized has commenced within one (1) year from the date of issuance; or b. The work has resumed within one (1) year from the date that construction begins. In the event of further construction after either of the above mentioned time periods, a new permit must be obtained pursuant to all the requirements of the code. (i) Penalty. Penalty for failure to obtain a permit before starting work shall be double the required fee. This shall be in addition to any other penalties provided elsewhere in the code. In addition, a penalty of one hundred dollars ($100) shall be assessed for each day that any work requiring a permit progresses without a permit, until the date the owner or contractor submits the proper plans in an approved format to the Chief. (j) Stop Work Order. The Chief has authority under this chapter to order the stoppage of work on any equipment or system covered by this chapter when such work is not authorized by the Chief or when such work is in violation of this chapter. (k) Failure to Schedule Final Inspection. A penalty fee of one hundred dollars ($100) shall be assessed to the applicant of a work permit, for failure to schedule a final inspection once work has been completed. (Cr. by ORD-22-00122, 12-3-22) (2) Fees. (a) Fees for Work Permits. 1. The fees fixed in this section shall be assessed and collected by the Chief for the examination of applications and design document and the issuance of Work Permits. These fees also include the inspection of newly installed and remodeled systems. These fees do not cover any re-inspections. These fees shall be paid in advance from the owner or agent. 2. Except as otherwise specified in this section, fees for new systems shall be computed upon the basis of the total square footage of each building or affected area. For the purpose of determining the fee on the basis of square foot, floor area measurements shall be taken from outside of the building at each floor level, including the basement and other areas affected or serviced by the system. Except as otherwise specified in this code, for remodeling or adding to an existing system, the appropriate fee shall be determined by calculating the square footage of the area to be serviced by such remodeling or addition to the system. 3. The fees for limited area systems or components are established in Sec. 34.02(2)(h). (Am. by ORD-22-00122, 12-3-22) (b) Process Fees. 1. Administrative Hold Fee. An additional fee of one hundred dollars ($100) shall be assessed for incomplete plan submittals placed on hold. 2. Denial of Approval Fee. The additional fee of two hundred fifty dollars ($250) or fifty percent (50%) of the original plan examination fee, whichever is higher, shall be assessed for review of system plans that have been submitted following denial of plan approval, if the submission is within eight (8) months of the original denial. A fee of two hundred fifty dollars ($250) shall be assessed for plan submittals that have been rejected for failing to comply with an administrative hold. 3. Plan Revision Fee. The fee of two hundred fifty dollars ($250) shall be assessed for revisions to previously approved plans. (c) A fee is not required for repair or component replacement. (d) The fee for the inspection only of devices/systems in state-owned buildings shall be fifty percent (50%) of the fees specified in this Chapter, but not less than one hundred twenty-five dollars ($125). (e) Except as otherwise specified in this section, plan review fees for modifications to existing systems shall be computed upon the basis of the total square footage of each building or affected area. (f) The fee for review of submittals or review of plans for any work to be performed under this section or the IFC, not specified in the fee schedules in this section, shall be two hundred fifty dollars ($250). (g) Fire Protection System Removal. 1. The permit fee shall be two hundred fifty dollars ($250). 2. No additional fee shall be due under this paragraph if the installation of a new system has been submitted to the Chief and for which a fee has been paid pursuant to this code. 3. A fee is not required for removal associated with razing of a building for which a permit is obtained from the City of Madison Building Inspection Division pursuant to Sec. 29.13, MGO. (h) Fee Schedule. 1. Sprinkler Systems (IFC 903) New systems and system modifications - See Area Table System modifications to include, but not limited to, the installation or relocation of 20 or fewer sprinklers or system components without a hydraulic impact - $125 Exception: The fee for one- and-two-family dwellings shall be waived. (Cr. by ORD-18-00103, 10-23-18) 2. Standpipe systems (not to include combined sprinkler/standpipe systems) New systems - See area table System modifications - $125 3. Private fire service mains and hydrants (IFC 507) that are not subject to a Plumbing Permit as issued by the City of Madison Building Inspection Unit New systems - $250 per system System modifications - $125 per system 4. Fire Alarm system (IFC 907) New systems and system modifications - See Area Table System modifications to include, but not limited to the installation or relocation of 3 or less fire alarm devices - $125 Replace fire alarm control panel - $250 5. Alarm Monitoring Systems (DACT, IP, Cellular, Radio transmitters) (IFC 907) New systems - $250 per system System modifications - $125 6. Fire detection devices that actuate fire doors/shutters (which are not part of any fire alarm system) New systems - $250 per system System modifications - $125 7. Alternative Automatic Fire-Extinguishing Systems (IFC 904) Exception: Commercial cooking suppression systems and Domestic cooking suppression systems in Group I-2, Condition 1 New systems - See Area Table System modifications to include, but not limited to, the installation or relocation of 3 or less devices (not to include control units) - $125 8. Commercial cooking suppression systems and domestic cooking suppression systems in Group I-2, Condition 1 New systems - $250 per system System modifications involving 3 or fewer components that do not have an impact on the manufacture's design - $125 9. Tanks for Flammable and Combustible Liquids and Federally Regulated Hazardous Substances Closure, change in use or temporary removal of any above-ground tank system, in excess of sixty (60) gallons and less than five thousand (5,000) gallons, regulated by ATCP 93 - $250 (Am. by ORD-22-00122, 12-3-22) 10. LP-Gas (IFC 61) Retail Cylinder Exchanges of more than 100 gallons, or aggregate - $250 each LPG Individual containers less than 2,000 gallons - $250 each LPG Individual containers aggregate less than 4,000 gallons - $250 each 11. Fixed outdoor fire feature $250 per feature 12. Outdoor Assembly capacity approval $250 annual or recurring event $50 one-time event $50 revisions 13. Smoke Control Panels New systems - $250 per panel System modifications - $125 14. Electronic lock hardware: Access Control, Delayed Egress, Locked Stair Door Systems New systems - $250 per 10 doors or fraction thereof System modifications - $125 15. Smoke and Heat Vents New systems and system modifications - $250 per system 16. High-piled Storage Arrays New high-piles storage arrays and modifications to high-piled storage arrays - See Area Table 17. Fire Command Center New command centers - $250 each Modifications to existing command centers - $125 each AREA TABLE AREA (SQUARE FEET) | FEE Less than 2,500 | $250 2,501 - 5,000 | $315 5,001 - 10,000 | $375 10,001 - 20,000 | $750 20,001 - 30,000 | $1,125 30,001 - 40,000 | $1,500 40,001 - 50,000 | $1,875 50,001 - 75,000 | $2,250 75,001 - 100,000 | $2,625 100,001 - 200,000 | $3,000 200,001 - 300,000 | $3,375 300,001 - 400,000 | $3,750 400,001 - 500,000 | $4,125 Over 500,000 | $4,500
(Am. by ORD-22-00122, 12-3-22) (Rpl. and rec. by ORD-18-00033, 3-28-18, eff. 5-1-18)
Ask a question about Madison law
Corpus searches the Madison sections it holds and shows the ones that match, with their citations. Free, no sign-in.
