Sec. 9-78. - Self-service motor fuel dispensing stations.

Definition; regulatory provisions. Self-service stations are defined as "that portion of property where flammable and combustible liquids used as motor fuels are stored, and subsequently dispensed from fixed equipment into the fuel tanks of motor vehicles by persons other than service station attendants, and shall include facilities available for the sale of other retail products," and the operation of such stations shall be subject to the following provisions: (a) Self-service dispensers: A remote controlled dispensing device approved by the authority having jurisdiction. The coin and/or the card operated type are not acceptable in the City of Providence. (b) Attendant required: All self-service stations shall have at least one qualified attendant on duty while the station is open to the public. During all times that class 1 liquids are actually being dispensed, the attendant's primary function shall be to supervise, observe and control the dispensing of said liquids. It shall be the responsibility of the attendant to prevent the dispensing of class 1 liquids into portable containers unless the container is constructed of metal or approved plastic, or is approved by the authority having jurisdiction, has a tight closure with screwed or spring cover, and is fitted with a spout or so designed that the contents can be poured without spilling. It shall also be the responsibility of the attendant to control sources of ignition, and to immediately handle accidental spills and fire extinguishers if needed. The attendant or supervisor on duty shall be capable of performing the functions and assuming the responsibilities covered in this section. (c) Attendant's control and supervision: At self-service stations, the attendant shall be required to remain within arm's length distance of the remote controlled console, at all times while class 1 liquids are being dispensed. A "post-payment operation" is advocated to insure the attendant's compliance with the foregoing provision. (d) Emergency controls: (1) A main power shut-off switch or switches shall be installed at a location not more than fifteen (15) feet from the attendant's principal control location, and not more than one hundred (100) feet from the dispensers. (2) A fixed fire extinguisher system suitable for the extinguishment of class B (flammable liquid) fires, acceptable to the authority having jurisdiction, and covering the entire gasoline dispensing area, shall be installed at each self-service station. Said system shall be capable of being activated, either manually or automatically; however, if it is to be activated manually, the triggering device shall not be more than fifteen (15) feet from the attendant's principal control location and not more than one hundred (100) feet from the dispensers. Activation of the fixed fire protection system shall automatically shut off the power supply to the dispensing devices on the island involved. "The entire gasoline dispensing area" referred to above is construed to mean the area encompassing the self-service island. If however, an adjacent attended island (normally serviced by a regular attendant dispensing motor fuel) is in too close proximity to the self-service island in the opinion of the authority having jurisdiction, then a fixed fire protection system may be required there also. (e) Operation instructions: Instructions for the operation of the dispensers shall be conspicuously posted on either the dispenser or the dispenser island. (f) Emergency procedures: A list of emergency procedures and instructions shall be conspicuously posted at the immediate vicinity of the attendant's principal control location. (g) Clear observation: The dispensing operation shall at all times be in clear view of the attendant, and the placing or allowing of any obstacle to come between the dispensing operation and the attendant, so as to obstruct the attendant's view, is prohibited. (h) Delivery nozzles: Hose nozzle valves used at self-service islands shall be an approved automatic closing type without a latch-open device. (i) Voice communication control: A voice communication system, such as, but not limited to, an intercom system, so as to allow direct voice communication at all times between the person dispensing the fuel and the attendant, shall be required. (j) Warning sign: On each and every dispenser island shall be conspicuously posted, the following words of warning: (1) WARNING … IT IS UNLAWFUL TO DISPENSE GASOLINE INTO ANY PORTABLE CONTAINER UNLESS THE CONTAINER IS CONSTRUCTED OF METAL OR IS APPROVED BY THE FIRE DEPARTMENT. (2) NO SMOKING. (3) SHUT OFF MOTOR WHILE MOTOR FUEL IS BEING DISPENSED.

(Ord. 1971, ch. 71-59, § 1, 10-26-71)

Ask a question about Providence law

Corpus searches the Providence sections it holds and shows the ones that match, with their citations. Free, no sign-in.