§ 6-37 — Deletions, additions, amendments

Code of Ordinances, City of Plano, Texas (Supp. No. 153: codified through Ordinance No. 2025-10-2, adopted October 13, 2025) · Plano City Code § 6-37

Corpus is an independent public-information project, not the official City of Plano website. Stable reference: corpuslaw.us/code/87e08260-9cc9-420d-8fdd-92e01b645216

Sec. 6-37. - Deletions, additions, amendments.

The following deletions, additions, and amendments to the International Building Code adopted in this Division are hereby approved and adopted: Sec. 101.4; change section to read as follows (Sections 101.4.1 through 101.4.7 to remain unchanged): Sec. 101.4 Referenced codes. The other codes listed in Sections 101.4.1 through 101.4.8 and referenced elsewhere in this code, when specifically adopted, shall be considered part of the requirements of this code to the prescribed extent of each such reference. Whenever amendments have been adopted to the referenced codes and standards, each reference to said code and standard shall be considered to reference the amendments as well. Any reference to NFPA 70 or the Electrical Code shall mean the Electrical Code as adopted. Sec. 101.4.8; add the following new section: Sec. 101.4.8 Electrical. The provisions of the Electrical Code shall apply to the installation of electrical systems, including alterations, repairs, replacement, equipment, appliances, fixtures, fittings and appurtenances thereto. Secs. 103 and 103.1;change to read as follows [Sections 103.2 and 103.3 to remain unchanged]: SECTION 103 BUILDING INSPECTIONS DEPARTMENT. Sec. 103.1 Creation of enforcement agency. The Building Inspections Department ("agency") is hereby created and the official in charge thereof shall be known as the building official. The function of the agency shall be the implementation, administration and enforcement of the provisions of the code. Sec. 104.2.4.1 Flood hazard areas; delete section in its entirety. Sec. 104.3.1 Determination of substantially improved or substantially damaged existing buildings and structures in flood hazard areas; delete section in its entirety. Sec. 105.1.1 change section to read as follows: Sec. 105.1.1 Toilet facilities. At least one permanent or temporary toilet facility shall be maintained at every site where a building permit has been issued, as long as a building permit is active for the project. Permanent toilet facility is defined as a room in an existing building or in the building being constructed with a water closet installed in such a room that conforms to the Plumbing Code and is continuously available to all workers involved in a construction project. Temporary toilet facility is defined as a portable, fully enclosed, chemically sanitized toilet, which is serviced and cleaned at least once each week. A Stop Work Order may be issued for any project not in compliance with this section. Sec. 105.1.2 Annual permit records; delete section in its entirety. Sec. 105.2 change the Building category to read as follows (all other provisions and text of Section 105.2 to remain unchanged): Building: 1. One-story detached accessory structures used as tool and storage sheds, playhouses and similar uses, provided that the floor area is not greater than 120 square feet (11 m 2 ). 2. [Item deleted.] 3. Oil derricks. 4. Retaining walls that are not over 4 feet (1219 mm) in height measured from the bottom of the footing to the top of the wall, unless supporting a surcharge or impounding Class I, II or IIIA liquids. 5. Water tanks supported directly on grade if the capacity is not greater than 5,000 gallons (18 925 L) and the ratio of height to diameter or width is not greater than 2:1. 6. Sidewalks and driveways not more than 30 inches (762 mm) above adjacent grade, and not over any basement or story below, and that are not part of an accessible route and not in the city right-of-way. 7. Painting, papering, tiling, carpeting, cabinets, counter tops and similar finish work. 8. Temporary motion picture, television and theater stage sets and scenery. 9. Prefabricated swimming pools accessory to a Group R-3 occupancy that are less than 24 inches (610 mm) deep, are not greater than 5,000 gallons (18 925 L), and are installed entirely above ground. 10. [Item deleted.] 11. Swings and other playground equipment accessory to detached one- and two-family dwellings. 12. Window awnings in Group R-3 and U occupancies, supported by an exterior wall that do not project more than 54 inches (1372 mm) from the exterior wall and do not require additional support. 13. Non-fixed and movable fixtures, cases, racks, counters and partitions not over 5 feet 9 inches (1753 mm) in height. Sec. 105.3 change section to read as follows: Sec. 105.3 Application for permit. To obtain a permit, the applicant shall first file an application therefor in writing on a form furnished by the department of building inspections for that purpose. Such application shall: 1. Identify and describe the work to be covered by the permit for which application is made. 2. Describe the land on which the proposed work is to be done by legal description, street address, or similar description that will readily identify and definitely locate the proposed building or work. 3. Indicate the use and occupancy for which the proposed work is intended. 4. Be accompanied by construction documents and other information as required in Section 107. 5. State the valuation of the proposed work. 6. Be signed by the applicant, or the applicant's authorized agent. 7. Give such other data and information as required by the building official. 8. Be issued to a registered contractor. General: To obtain a permit, the applicant shall be registered as a contractor. A contractor may register by making application on forms provided by the building official. Exception: 1. Homeowners may obtain permits for their private residence without being registered, however a contractor working under the homeowner's permit must meet state requirements for license registration. 2. Contractors exempt from local registration fees must show proof of state license. Revocation/Suspension: A contractor's registration may be suspended for the following causes: 1. The contractor fails to finalize permits by obtaining the required approved inspections. 2. The contractor allows use or occupancy of a structure for which a permit was obtained without first obtaining the required authorization. 3. Expiration, suspension or revocation of required license or insurance. Sec. 105.3.1; change section to read as follows: Sec. 105.3.1 Action on application. The building official shall examine or cause to be examined applications for permits and amendments thereto within a reasonable time after filing in compliance with state law. If the application or the construction documents do not conform to the requirements of pertinent laws, the building official shall reject such application in writing, stating the reasons therefor. If the building official is satisfied that the proposed work conforms to the requirements of this code and laws and ordinances applicable thereto, the building official shall issue a permit therefor as soon as practicable. A demolition permit may be withheld for any building or structure within the Plano Historic Building and Site Survey as designated in the Preservation Plan for a period not exceeding thirty (30) days pending review by the Heritage Commission. Sec. 105; change Section 105 by adding a new Section 105.8 to read as follows: Sec. 105.8. Withdrawn permits. Permits may be withdrawn by the applicant if no work has commenced on the project. Permit fees exceeding $100.00 may be partially refunded. Where applicable, fees will be refunded at 80 percent of their original value, excluding the plan review and fire protection plan review deposits. Permits for which work has commenced may not be withdrawn unless a subsequent permittee has obtained a permit to complete the work, or when work has started unless an inspection has been made and the building official has determined that the existing work has created no violation of any code or ordinance. Expired permits may be withdrawn if determined by the building official that no work has commenced. Withdrawn permits with fees of less than one hundred ($100) dollars are nonrefundable. Sec. 107.3.1; change section to read as follows: Sec. 107.3.1 Approval of construction documents. When the building official issues a permit, the construction documents shall be approved, in writing, or by a stamp which states, "APPROVED AND APPROVED AS NOTED BY THE BUILDING OFFICIAL." One set of construction documents so reviewed shall be retained by the building official. The other set shall be returned to the applicant, shall be kept at the site of the work, and shall be open to inspection by the building official or a duly authorized representative. Sec. 109; change Section 109 by adding Sections 109.7, 109.8, 109.9, and 109.10 to read as follows: Sec. 109.7 Re-inspection fee. A fee, as established by city council resolution, may be charged when: 1. The inspection called for is not ready when the inspector arrives. 2. No building address or permit card is clearly posted. 3. City-approved plans are not on the job site available to the inspector. 4. The building is locked or work otherwise is not available for inspection when called. 5. The job site is red-tagged twice for the same item. 6. The original red tag has been removed from the job site. 7. There is a failure to maintain erosion control, trash control, or tree protection. Any re-inspection fees assessed shall be paid before any more inspections are made on that job site. Sec. 109.8 Work without a permit; Investigation. Whenever work for which a permit is required by this code has been commenced without first obtaining a permit, a special investigation shall be made before a permit may be issued for such work. Sec. 109.9 Fee. An investigation fee, in addition to the permit fee, shall be collected whether or not a permit is subsequently issued. The investigation fee shall be equal to the amount of the permit fee required by this code or the city fee schedule, as applicable. The payment of such investigation fee shall not exempt the applicant from compliance with all other provisions of either this code or the technical codes nor from penalty prescribed by law. Sec. 109.10 Unauthorized cover up fee. Any work concealed without first obtaining the required inspection in violation of Section 110 shall be assessed a fee as established by the city fee schedule. Section 110.3.6; Lath, gypsum board and gypsum panel product inspection; the Exception is deleted in its entirety; remainder of section is unchanged. Sections 111.1, 111.2, 111.2.1 and 111.2.2; amended and added to read as follows: Sec. 111.1 Change of occupancy. A building or structure shall not be used or occupied in whole or in part until the building official has issued a certificate of occupancy therefor as provided herein. A change in legal or assumed name of the business, the names of the business owners, the occupancy classification of a building or structure, or any change in the purpose of, or a change in the level of activity within, a building or structure or portion thereof shall not be made before issuance of a new certificate of occupancy. Issuance of a certificate of occupancy shall not be construed as an approval of a violation of the provisions of this code or of other ordinances of the jurisdiction. Certificates presuming to give authority to violate or cancel the provisions of this code or other ordinances of the jurisdiction shall not be valid. Sec. 111.2 Certificate issued. After the building official inspects the building or structure and does not find violations of this code or other laws that are enforced by the department, the building official shall issue a certificate of occupancy that contains the following: 1. The permit number. 2. The address of the structure. 3. The legal or assumed name of the business. 4. The name(s) and addresses of owner(s). 5. A description of that portion of the structure for which the certificate is issued. 6. A statement that the described portion of the structure has been inspected for compliance with the requirements of this code. 7. The name of the building official. 8. The edition of the code under which the permit was issued. 9. The use and occupancy, in accordance with the provisions of Chapter 3 and the Comprehensive Zoning Ordinance. 10. The type of construction as defined in Chapter 6. 11. The design occupant load. 12. Where an automatic sprinkler system is provided, whether the sprinkler system is required. 13. Any special stipulations and conditions of the building permit. Sec. 111.2.1 Grace period for changes to information provided within a certificate of occupancy issued by the building official. The designated contact person, authorized agent, or owner(s) must submit an application for a new certificate of occupancy regarding a change to any of the following within 30 days of such change: 1. The legal or assumed name of the business; 2. The name(s) of the business owner(s). Sec. 111.2.2 Voluntary surrender of a certificate of occupancy. An owner of the occupancy may voluntarily surrender their certificate of occupancy. A voluntary surrender of a certificate of occupancy must be presented to the building official in writing. Upon the building official's receipt of the written statement of surrender, the certificate of occupancy is void, and no use or occupancy, in whole or in part, may be made of the building or structure until a new certificate of occupancy has been applied for and issued by the building official. Section 113; change the title of the section and Section 113.1 to read as follows: SECTION 113 BUILDING STANDARDS COMMISSION. Sec. 113.1 General. In order to hear and decide appeals of orders, decisions, or determinations made by the building official relative to the application and interpretation of this code, there shall be and is hereby created a building standards commission ("commission," "board," or "board of appeals"). The commission shall be appointed by the Plano City Council and shall hold office at its pleasure. The commission shall adopt rules of procedure for conducting its business and shall render all decisions and findings in writing to the appellant with a duplicate copy to the building official. Sections 111.4 and 111.4.1; amended and added to read as follows: Sec. 111.4 Revocation. The building official is authorized to suspend or revoke a certificate of occupancy or completion issued under the provisions of this code, in writing, in the following instances: 1. The certificate was issued in error. 2. The certificate was issued on the basis of incorrect information supplied by the applicant or certificate holder. 3. The applicant or certificate holder failed to obtain a new certificate of occupancy after a change of occupancy in accordance with Section 111.1 or a change to the ownership of the business or in the legal or assumed name of the business, in accordance with the provisions of Section 111.2.1. 4. Where it is determined that the building or structure or portion thereof is in violation of the provisions of this code or other ordinance of this jurisdiction. Sec. 111.4.1 Revocation procedures for a certificate of occupancy. If the certificate of occupancy is revoked as a result of error, misinformation, or violation of any provision in the Plano Zoning Ordinance, the appeal procedures contained in the Zoning Ordinance apply and must be followed. If the certificate of occupancy is revoked as a result of error, misinformation, or violation of any provision of this code or other ordinance of this jurisdiction that is not contained in the Zoning Ordinance, the appeal procedures contained in this code apply and must be followed. Section 202; change the definition of "Ambulatory Care Facility" as follows: AMBULATORY CARE FACILITY. Buildings or portions thereof used to provide medical, surgical, psychiatric, nursing or similar care on a less than 24-hour basis to persons who are rendered incapable of self-preservation by the services provided. This group may include, but not be limited to, the following: - Dialysis centers - Sedation dentistry - Surgery centers - Colonic centers - Psychiatric centers Section 202; add a definition of "Assisting Living Facilities" to read as follows: ASSISTED LIVING FACILITIES. A building or part thereof housing persons, on a 24-hour basis, who because of age, mental disability or other reasons, live in a supervised residential environment which provides personal care services. The occupants are capable of responding to an emergency situation without physical assistance from staff. Section 202; add a definition of "High-piled Combustible Storage" to read as follows: HIGH-PILED COMBUSTIBLE STORAGE. 1. Storage of combustible materials in closely packed piles or combustible materials on pallets, in racks or on shelves where the top of storage is greater than 12 feet (3658 mm) in height. Where required by the fire code official, high-piled combustible storage also includes certain high-hazard commodities, such as rubber tires, Group A plastics, flammable liquids, idle pallets and similar commodities, where the top of storage is greater than 6 feet (1829 mm) in height. 2. Any building classified as a group S Occupancy or Speculative Building exceeding 6,000 sq. ft. that has a clear height in excess of 14 feet, making it possible to be used for storage in excess of 12 feet, shall be considered to be high-piled storage. When a specific product cannot be identified (speculative warehouse), a fire protection system and life safety features shall be installed for Class IV commodities, to the maximum pile height. Section 202; change the definition of "High-Rise Building" to read as follows: HIGH-RISE BUILDING. A building with an occupied floor located more than 55 feet (16 764 mm) above the lowest level of fire department vehicle access. Section 202; change the definition of "Repair Garage" to read as follows: REPAIR GARAGE. A building, structure or portion thereof used for servicing or repairing motor vehicles. This occupancy shall also include garages involved in minor repair, modification and servicing of motor vehicles for items such as lube changes, inspections, windshield repair or replacement, shocks, minor part replacement, and other such minor repairs. Section 202; change the definition of "Special Inspector" to read as follows: SPECIAL INSPECTOR. A qualified person employed or retained by an approved agency who shall prove to the satisfaction of the registered design professional in responsible charge and the building official as having the competence necessary to inspect a particular type of construction requiring special inspection. Section 303.1.3; change section to read as follows: Sec. 303.1.3 Associated with Group E occupancies. A room or space used for assembly purposes that is associated with a Group E occupancy is not considered a separate occupancy, except when applying the assembly requirements of Chapters 10 and 11. Section 304.1; add the following to the list of occupancies in Section 304.1 Business Group B: Fire stations Police stations with detention facilities for 5 or less Table 307.1.1 Hazardous Materials Exemptions; change the exemption for "Cleaning establishments with combustible liquid solvents" in Table 307.1.1 to read as follows: Table 307.1.1 Hazardous Materials Exemptions. Cleaning establishments with combustible liquid solvents having a flash point of 140°F (60°C) or higher in closed systems employing equipment listed by an approved testing agency, provided that this occupancy is separated from all other areas of the building by 1-hour fire barriers constructed in accordance with Section 707 of 1-hour horizontal assemblies constructed in accordance with Section 711 or both. See also IFC Chapter 21, Dry Cleaning Plant provisions. Section 403.1; change section to read as follows: Sec. 403.1 Applicability. High-rise buildings shall comply with Sections 403.2 through 403.6. Exceptions: The provisions of Sections 403.2 through 403.6 shall not apply to the following buildings and structures: 1. Airport traffic control towers in accordance with Section 412.2. 2. Open parking garages in accordance with Section 406.5. 3. The open air portion of a building containing a Group A-5 occupancy in accordance with Section 303.6. 4. Special industrial occupancies in accordance with Section 503.1.1. 5. Buildings containing any one of the following: 5.1 A Group H-1 occupancy. 5.2 A Group H-2 occupancy in accordance with Section 415.8, 415.9.2, 415.9.3 or 426.1 5.3 A Group H-3 occupancy in accordance with Section 415.8. Sec. 403.3; change section to read as follows (Exception deleted): Sec. 403.3 Automatic sprinkler system. Buildings and structures shall be equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1 and a secondary water supply where required by Section 403.3.3. Section 403.3.2; change section to read as follows: Sec. 403.3.2 Water supply to required fire pumps. In buildings that are more than 120 feet (36.5 m) in building height, required fire pumps shall be supplied by connections to no fewer than two water mains located in different streets. Separate supply piping shall be provided between each connection to the water main and the pumps. Each connection and the supply piping between the connection and the pumps shall be sized to supply the flow and pressure required for the pumps to operate. Exception: Two connections to the same main shall be permitted provided that the main is valved such that an interruption can be isolated so that the water supply will continue without interruption through no fewer than one of the connections. Section 406.3.3.1; change section to read as follows: Sec. 406.3.3.1 Carport separation. A fire separation is not required between a Group R-2 and U carport provided that the carport is entirely open on all sides and that the distance between the two is at least 10 feet (3048 mm). A separation is not required between any occupancy and an accessory U carport provided the carport is entirely open on all sides, the eave-to-eave or eave-to-property line (assumed or real) horizontal separation is at least 5 (five) feet, constructed of noncombustible materials and for the storage of automobiles. Shade structures used for commercial playgrounds or commercial use do not require fire separations provided shading materials have flame-retardant certificates and framing members are of non-combustible construction. Section 502.1; change section to read as follows: Sec. 502.1 Address identification. Approved numerals of minimum six (6) inches in height and of a color contrasting with the background designating address shall be placed on all new and existing buildings or structures as to be plainly visible and legible from the street or road fronting the property and from all rear alleyways where said alleyways exist. Where buildings do not immediately front a street, approved six (6) inch in height building numerals or address and three (3) inch in height suite/apartment numerals of a color contrasting with the background of the building shall be placed on all new and existing buildings or structures. Numerals or addresses shall be posted on a minimum twenty (20) inch by thirty (30) inch background or border. Section 503.1; change section to read as follows: Sec. 503.1 General. Unless otherwise specifically modified in Chapter 4 and this chapter, building height, number of stories and building area shall not exceed the limits specified in Sections 504 and 506 based on the type of construction as determined by Section 602 and the occupancies as determined by Section 302 except as modified hereafter. Building height, number of stories and building area provisions shall be applied independently. For the purposes of determining area limitations, height limitations and type of construction, each portion of a building separated by one or more fire walls complying with Section 706 shall be considered to be a separate building. Where a building contains more than one distinct type of construction, the building shall comply with the more restrictive building area, height, and stories for the lesser type of construction or be separated by fire walls, except as allowed in Section 510. Table 506.2 Allowable Area Factor in Square Feet; delete footnote "i" from the table. Sec. 506.3.1; change section to read as follows: Sec. 506.3.1 Minimum percentage of perimeter. To qualify for an area factor increase based on frontage, a building shall have not less than 25 percent of it perimeter on a public way or open space. Such open space shall be either on the same lot or dedicated for public use and shall be accessed from a street or approved fire lane. In order to be considered as accessible, if not in direct contact with a street or fire lane, a minimum 10-foot-wide pathway meeting fire department access from the street or approved fire lane shall be provided. Section 602.1.1; change section to read as follows: Sec. 602.1.1 Minimum requirements. A building or portion thereof shall not be required to conform to the details of a type of construction higher than that type which meets the minimum requirements based on occupancy even though certain features of such a building actually conform to a higher type of construction. Where a building contains more than one distinct type of construction, the building shall comply with the most restrictive building area, height, and stories, for the lesser type of construction or be separated by fire walls in accordance with Section 706. Sec. 708.4.3; change Exception 1 of Section 708.4.3 "Fireblocks and draftstops in combustible construction" to read as follows (remainder of section and exceptions are unchanged): 1. Buildings equipped with an automatic sprinkler system installed throughout in accordance with Section 903.3.1.1, or in accordance with Section 903.3.1.2 provided that protection is provided in the space between the top of the fire partition and underside of the floor or roof sheathing, deck or slab above as required for systems complying with Section 903.3.1.1. Portions of buildings containing concealed spaces filled with noncombustible insulation, as permitted for sprinkler omission, shall not apply to this exception for draftstopping. Sec. 718.3; change Exception of Section 718.3 "Draftstops in floors" to read as follows (remainder of section is unchanged): Exception: Buildings equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1 and provided that in combustible construction, sprinkler protection is provided in the floor space. Sec. 718.4; change Exception of Section 718.4 "Draftstops in attics" to read as follows (remainder of section is unchanged): Exception: Buildings equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1 and provided that in combustible construction, sprinkler protection is provided in the attic space. SECTION 901 GENERAL. Sec. 901.5; amended by the addition of the following to the first paragraph: All required tests shall be conducted by and at the expense of the owner or his representative. The Fire Department shall not be held responsible for any damages incurred in such test. Where it is required that the Fire Department witness any such test, such test shall be scheduled with a minimum of 48-hour notice to the Fire Chief or his representative. Sec. 901.7 is amended to read as follows: Sec. 901.7 Systems out of service. Where a required fire protection system is out of service or in the event of an excessive number of activations, alarms or unwanted alarms, the fire department and the code official shall be notified immediately and, where required by the code official, the building shall either be evacuated or standby personnel shall be provided for all occupants left unprotected by the shut down until the fire protection system has been returned to service. Where utilized, standby personnel shall be provided with at least one approved means for notification of the fire department and their only duty shall be to perform constant patrols of the protected premises and keep watch for fires. SECTION 903 AUTOMATIC SPRINKLER SYSTEMS. Sec. 903.1.1 is amended to read as follows: Sec. 903.1.1 Alternative protection. Alternative automatic fire-extinguishing systems complying with Section 904 shall be permitted in addition to automatic sprinkler protection where recognized by the applicable standard and, or as approved by the fire code official. Sec. 903.2 is amended to read as follows: Sec. 903.2 Where required. Approved automatic sprinkler systems in new buildings and structures shall be provided in the locations described in Sections 903.2.1 through 903.2.12. Automatic Sprinklers shall not be installed in elevator machine rooms, elevator machines spaces, and elevator hoist ways. Storage shall not be allowed within the elevator machine room. Sec. 903.2 is amended by deleting the Exception. Secs. 903.2.1.1, 903.2.1.3, 903.2.1.4, are amended to read as follows: Sec. 903.2.1.1 Group A-1. An automatic sprinkler system shall be provided for Group A-1 Occupancies where one of the following conditions exists: 1. The fire area exceeds 6,000 square feet (557.4m 2 ). 2. The fire area has an occupant load of 300 or more. 3. The fire area is located on a floor other than the level of exit discharge. 4. The fire area contains a multi theater complex. Sec. 903.2.1.3 Group A-3. An automatic sprinkler system shall be for Group A-3 Occupancies where one of the following conditions exists: 1. The fire area exceeds 6,000 square feet (557.4m 2 ). 2. The fire area has an occupant load of 300 or more. 3. The fire area is located on a floor other than the level of exit discharge. Sec. 903.2.1.4 Group A-4. An automatic sprinkler system shall be provided for Group A-4 Occupancies where one of the following conditions exists: 1. The fire area exceeds 6,000 square feet (557.4m 2 ). 2. The fire area has an occupant load of 300 or more. 3. The fire area is located on a floor other than the level of exit discharge. Sec. 903.2.2 is amended to read as follows: Sec. 903.2.2 Group B. An automatic sprinkler system shall be provided for Group B occupancies as required in Sections 903.2.2.1, 9.3.2.2.2, and 903.2.2.3. Add new section 903.2.2.3 to read as follows: Sec. 903.2.2.3 Fire area. Where a Group B fire area exceeds 6,000 square feet (557.4 meters squared). Secs. 903.2.3, 903.2.4, 903.2.4.2, 903.2.7, 903.2.9, 903.2.9.1, and 903.2.9.3 are amended to read as follows: Sec. 903.2.3 Group E. An automatic sprinkler system shall be provided for Group E Occupancies where one of the following conditions exists: 1. Throughout all Group E fire areas greater than 6,000 square feet (557.4m 2 ) in area. 2. Throughout every portion of educational building below the level of exit discharge. Exception: An automatic sprinkler system is not required in any fire area or area below the level of exit discharge where every classroom throughout the building has at least one exterior exit door at ground level. 3. The Group E fire area has an occupant load of 300 or more. Sec. 903.2.4 Group F-1. An automatic sprinkler system shall be provided throughout all buildings containing a Group F-1 Occupancy where one of the following conditions exists: 1. Where a Group F-1 fire area exceeds 6,000 square feet (557.4m 2 ); 2. Where a Group F-1 fire area is located more than three stories above grade plane; or 3. Where combined area of all Group F-1 fire areas on all floors, including any mezzanines, exceeds 24,000 square feet (2230m 2 ). 4. A Group F-1 occupancy is used to manufacture lithium-ion or lithium metal batteries. 5. A Group F-1 occupancy is used to manufacture vehicles, energy storage systems or equipment containing lithium-ion or lithium metal batteries where the batteries are installed as part of the manufacturing process. Sec. 903.2.4.2 Group F-1 distilled spirits. An automatic sprinkler system shall be provided throughout a Group F-1 fire area used for the manufacture of distilled spirits involving more than 120 gallons of distilled spirits (>20% alcohol) in the fire area at any one time. Sec. 903.2.7 Group M. An automatic sprinkler system shall be provided throughout all buildings containing a Group M Occupancy where one of the following conditions exists: 1. Where a Group M fire area exceeds 6,000 square feet (557.4m 2 ). 2. Where a Group M fire area is located more than three stories above grade plane. 3. Where the combined area of all Group M fire areas on all floors, including any mezzanines, exceeds 24,000 square feet (2230m 2 ). Sec. 903.2.9 Group S-1. An automatic sprinkler system shall be provided throughout all buildings containing a Group S-1 Occupancy where one of the following conditions exists: 1. A Group S-1 fire area exceeds 6,000 square feet (557.4m 2 ). 2. A Group S-1 fire area is located more than three stories above grade plane. 3. The combined area of all Group S-1 fire areas on all floors, including any mezzanines, exceeds 24,000 square feet (2230m 2 ). 4. A Group S-1 fire area used for the storage of commercial trucks or buses where the fire area exceeds 5,000 square feet (464m 2 ). 5. A Group S-1 fire area used for the storage of lithium-ion or lithium metal powered vehicles where the fire area exceeds 500 square feet (46.4m 2 ). Sec. 903.2.9.1 Repair garages. An automatic sprinkler system shall be provided throughout all buildings used as Repair Garages where one of the following conditions exists: 1. Buildings two or more stories in height, including basements, with a fire area containing a repair garage exceeding 6,000 square feet (557.4m 2 ). 2. One-story buildings with a fire area containing a repair garage exceeding 6,000 square feet (557.4m 2 ). 3. Buildings with a repair garage servicing vehicles parked in the basement. 4. A Group S-1 fire area used for the repair of commercial trucks or buses where the fire area exceeds 5,000 square feet (464m 2 ). 5. A Group S-1 fire area used for the storage of lithium-ion or lithium metal powered vehicles where the fire area exceeds 500 square feet (46.4m 2 ). Sec. 903.2.9.3 Group S-1 distilled spirits or wine. An automatic sprinkler system shall be provided throughout a Group S-1 fire area used for the bulk storage of distilled spirits or wine involving more than 120 gallons of distilled spirits or wine (>20% alcohol) in the fire area at any one time. Sec. 903.2.9.4 is amended by the deleting the exception. Sec. 903.2.9; add new Section 903.2.9.5 to read as follows: Sec. 903.2.9.5 Self-service storage facility. An automatic sprinkler system shall be installed throughout all self-service storage facilities. A screen shall be installed at eighteen (18) inches below the level of the sprinkler heads to restrict storage above that level. This screen shall be a mesh of not less than one (1) inch nor greater than six (6) inches in size. The screen and its supports shall be installed such that all elements are at least eighteen (18) inches below any sprinkler heads. Sec. 903.2.10 is amended be the addition of a 4thcondition: Sec. 903.2.10 Group S-2 parking garages. An automatic sprinkler system shall be provided throughout buildings classified as parking garages where any of the following conditions exist: 1. Where the fire area of the enclosed parking garage, in accordance with Section 406.6 of the International Building Code, exceeds 12,000 square feet (1115 m 2 ). 2. Where the enclosed parking garage, in accordance with Section 406.6 of the International Building Code, is located beneath other groups. Exception: Enclosed parking garages located beneath Group R-3 occupancies. 3. Where the fire area of the open parking garage, in accordance with Section 406.5 of the International Building Code, exceeds 48,000 square feet (4460 m 2 ). 4. Where two or more sides of the garage are not accessible by the Fire Department ladder truck. Sec. 903.2.11.3 is amended to read as follows and deleting the exception: Sec. 903.2.11.3 Buildings 35 feet or more in height. An automatic sprinkler system shall be installed throughout buildings that have one or more stories with an occupant load of 30 or more, other than penthouses in compliance with Section 1511 of the International Building Code, located 35 feet (10,688 mm) or more above the lowest level of fire department vehicle access, measured to the finished floor. Sec. 903.2.11; add new Sections 903.2.11.7, 903.2.11.8, 903.2.11.9, and 903.2.11.10 to read as follows: Sec. 903.2.11.7 High piled combustible storage. For any building with a clear height exceeding 12 feet (4,572 mm), see Chapter 32 to determine if those provisions apply. Sec. 903.2.11.8 Spray booths and rooms. New and existing spray booths and spraying rooms shall be protected by an approved automatic fire-extinguishing system. Sec. 903.2.11.9 Buildings over 6,000 sq. ft. An automatic sprinkler system shall be installed throughout all buildings over 6,000 sq. ft. and greater, and in all existing buildings that are enlarged to be 6,000 square feet or greater, and in buildings greater than 6,000 square feet which are enlarged. For the purpose of this provision, fire walls, fire barriers, or horizontal assemblies shall not define separate buildings. Exceptions: 1. Parking garages in compliance with Section 903.2.10 of the International Fire Code. 2. When of non-combustible construction, the area of awning extension or free-standing canopies, both sides, and not used for display or storage shall not be considered for requiring sprinkler protection for areas greater than 6,000 square feet but less than otherwise required in this code. Sec. 903.2.11.10 Expanded tenant spaces. Fire sprinklers shall be installed in all tenant spaces where the total fire area exceeds 6,000 square feet. For the purpose of fire sprinklers, fire walls, fire barriers, or horizontal assemblies shall not be used to separate single tenant fire areas. Sec. 903.3.1.1.1 is amended to read as follows: Sec. 903.3.1.1.1 Exempt locations. When approved by the fire code official, automatic sprinklers shall not be required in the following rooms or areas where such rooms or areas are protected with an approved automatic fire detection system in accordance with Section 907.2 that will respond to visible or invisible particles of combustion. Sprinklers shall not be omitted from any room merely because it is damp, of fire-resistance-rated construction or contains electrical equipment. 1. Any room where the application of water, or flame and water, constitutes a serious life or fire hazard. 2. Generator and transformer rooms, under the direct control of a public utility, separated from the remainder of the building by walls and floor/ceiling or roof/ceiling assemblies having a fire-resistance rating of not less than 2 hours. 3. Elevator machine rooms, machinery spaces, and hoist ways, other than pits where such sprinklers would not necessitate shunt trip requirements under any circumstances. Sec. 903.3.1.2 is amended by adding the following paragraph at the end. Sec. 903.3.1.2 NFPA 13R Sprinkler Systems. Where allowed in buildings of Group R, up to and including four stories in height, automatic sprinklers shall be installed throughout in accordance with NFPA 13R. Sprinkler systems installed in accordance with 13R shall include sprinkler protections in combustible attics of buildings two (2) or more stories in height. Sec. 903.3.1; add new Sections 903.3.1.4 and 903.3.1.5 to read as follows: Sec. 903.3.1.4 Freeze protection. Freeze protection systems for automatic fire sprinkler systems shall be in accordance with the requirements of the applicable referenced NFPA standard and this section. Sec. 903.3.1.4.1 Attics. Only dry-pipe, preaction, or listed antifreeze automatic fire sprinkler systems shall be allowed to protect attic spaces. Exception: Wet-pipe fire sprinkler systems shall be allowed to protect non-ventilated attic spaces where: 1. The attic sprinklers are supplied by a separate floor control valve assembly to allow ease of draining the attic system without impairing sprinklers throughout the rest of the building, and 2. Adequate heat shall be provided for freeze protection as per the applicable referenced NFPA standard, and 3. The attic space is a part of the building's thermal, or heat, envelope, such that insulation is provided at the roof deck, rather than at the ceiling level. Sec. 903.3.1.4.2 Heat trace/insulation. Heat trace/insulation shall only be allowed where approved by the fire code official for small sections of large diameter water-filled pipe. Sec. 903.3.1.5 Installation. Automatic sprinkler and standpipe systems shall be installed with the following: 1. A single underground supply from a looped water main and point for the Fire Department Connection (FDC) shall be provided for all buildings. 2. Fire department connections for automatic sprinklers and standpipes shall be provided with one 5-inch Storz connection. For system demands greater than 150 psi an additional 2½ inch Siamese connection and sign identifying pressure demand shall be required. Each shall have an independent check valve. 3. All inspectors' test, ball-drips, and main-drains shall be piped directly to the outside of the building. 4. At least one inspection test valve shall be located at the remote system area. 5. Fire pumps shall be equipped with a properly sized test header. 6. Underground piping shall have a 10-foot minimum separation from all other utilities and placed in a separate trench. Underground piping within 5 feet of the building may be combined with other utilities for entrance to the building. 7. Porches and balconies shall be sprinkled on all Group R-2 and R-3 occupancies. 8. A minimum of 4-feet of pipe between the check valve and inside wall of the Fire Department Connection. Sec. 903.3.5 is amended to include a second paragraph to read as follows: Water supply as required for automatic sprinkler and automatic standpipe systems shall be provided in conformance with the supply requirements of the respective standards; however, every fire protection system shall be designed with a 10-psi safety factor. Sec. 903.3.9 is amended to read as follows: Sec. 903.3.9 Floor control valves. Approved supervised indicating control valves shall be provided at the point of connection to the riser on each floor. Sec. 903.4.1 is amended to include a second paragraph after the exceptions to read as follows: Sec. 903.4.1 Electronic supervision. Sprinkler and standpipe system water-flow detectors shall be provided for each floor tap to the sprinkler system and shall cause an alarm upon detection of water flow for a minimum of 45 seconds and not more than 90 seconds. All control valves in the sprinkler and standpipe systems except for fire department hose connection valves shall be electrically supervised to initiate a supervisory signal at the central station upon tampering. Sec. 903.4.3 is amended to include a second paragraph to read as follows: Sec. 903.4.3 Alarms. The alarm device required on the exterior of the building shall be a weatherproof horn/strobe notification appliance with a minimum 75 candela strobe rating, installed as close as practicable to the fire department connection. SECTION 905 STANDPIPE SYSTEMS. Sec. 905.2 is amended to read as follows: Sec. 905.2 Installation standards. Standpipe system shall be installed in accordance with this section and NFPA 14. Manual dry standpipe systems shall be supervised with a minimum of 10 psig and a maximum of 40 psig air pressure with a high/low alarm. Sec. 905.3.2 Group A; is amended by deleting exceptions 1 and 2. Sec 905.3 is amended by adding new Section 905.3.8 to read as follows: Sec. 905.3.8 Travel distance. Class I standpipes shall also be required on all occupancies in which the distance from accessible points for Fire Department ingress to any point in the structure exceeds two hundred fifty feet (250') along the route that a fire hose is laid as measured from the fire lane. Sec. 905.4 Location of class I standpipe hose connections item 5 is amended to read as follows: 5. Where the roof has a slope less than four units vertical in 12 units horizontal (33.3-percent slope), each standpipe shall be provided with a two-way hose connection located either on the roof or at the highest landing of stairways with stair access to the roof. An additional hose connection shall be provided at the top of the most hydraulically remote standpipe for testing purposes. Sec. 905.4 is amended to by the addition of item 7 as follows: 7. When required by this Chapter, standpipe connections shall be placed adjacent to all required exits to the structure and at two hundred feet (200') intervals along major corridors or pathways thereafter. Sec. 905; is amended by deleting Section 905.5. Sec. 905; is amended by deleting Section 905.6. Sec. 905.9 is amended to add a second paragraph after the exceptions to read as follows: Sec. 905.9 Valve supervision. Sprinkler and standpipe system water-flow detectors shall be provided for each floor tap to the sprinkler system and shall cause an alarm upon detection of water flow for a minimum of 45 seconds and not more than 90 seconds. All control valves in the sprinkler and standpipe systems except for fire department hose connection valves shall be electrically supervised to initiate a supervisory signal at the central station upon tampering. Sec. 905.11; is amended to read as follows: Sec. 905.11 Locking standpipe outlet caps. Locking standpipe caps are on the outlets of dry standpipe connections where the responding fire department carries appropriate key wrenches for removal that are compatible with locking FDC connection caps. Locking caps are required on all new systems and existing systems where caps are missing. Sec. 905 Standpipe systems is amended by adding section 905.13 to read as follows: Sec. 905.13 Manual systems. Design required for such systems shall be provided in conformance with the supply requirements of the respective standards. However, every manual fire protection system shall be designed with a supply of 150 psi at the FDC. SECTION 906 PORTABLE FIRE EXTINGUISHERS. Sec. 906.1 is amended by deleting 906.1(1) exception 3. SECTION 907 FIRE ALARM AND DETECTION SYSTEMS. Sec. 907.1.1 is amended by adding the following sentence: Sec. 907.1.1 Construction documents. Plans for fire alarm systems shall be in accordance with Plano Fire-Rescue's Fire Alarm Submittal Guidelines. Sec. 907.1 is amended by adding new Section 907.1.4 to read as follows: Sec. 907.1.4 Design standards. All alarm systems new or replacement shall be addressable. Alarm systems serving more than 20 smoke detectors shall be analog addressable. Exception: Existing systems need not comply unless the total building remodel or expansion initiated after January 1, 1998, as adopted, exceeds 30% of the building. When cumulative building remodel or expansion exceeds 50% of the building must comply within 18 months of permit application. Sec. 907.2.1 is amended to read as follows: Sec. 907.2.1 Group A. A manual fire alarm system that activates the occupant notification system in accordance with new Section 907.5 shall be installed in Group A occupancies having an occupant load of 300 or more persons or more than 100 persons above or below the lowest level of exit discharge. Group A occupancies not separated from one another in accordance with Section 707.3.10 of the International Building Code shall be considered as a single occupancy for the purposes of applying this section. Portions of Group E occupancies occupied for assembly purposes shall be provided with a fire alarm system as required for the Group E occupancy. Exception: Manual fire alarm boxes are not required where the building is equipped throughout with an automatic sprinkler system installed in accordance with Section 903.3.1.1 and the occupant notification appliances will activate throughout the notification zones upon sprinkler water flow. Activation of fire alarm notification appliances shall: 1. Cause illumination of the means of egress with light of not less than 1 footcandle (11 lux) at the walking surface level, and 2. Stop any conflicting or confusing sounds and visual distractions. Sec. 907.2.3 is amended to read as follows, Exceptions to remain: Sec. 907.2.3 Group E. A manual alarm system that initiates the occupant notification signal utilizing an emergency voice/alarm communication system meeting the requirements of Section 907.5.2.2 and installed in accordance with Section 907.6 shall be installed in Group E educational occupancies. When automatic sprinkler systems or smoke detectors are installed, such systems or detectors shall be connected to the building fire alarm system. An approved smoke detection system shall by installed in Group E day care occupancies. Unless separated by a minimum of 100' open space, all buildings, whether portable buildings or the main building, will be considered one building for alarm occupant load consideration and interconnection of alarm systems. Where automatic fire sprinklers are not provided, a full-coverage smoke detection system shall be provided in all Group E occupancies. Sec. 907.2.3, Exception 1 is amended to read as follows: 1. A manual fire alarm system is not required in Group E educational and day care occupancies with an occupant load of less than 50 when provided with an approved automatic sprinkler system. Sec. 907.2.3; add new Section 907.2.3.1 to read as follows: Sec. 907.2.3.1 In-home daycare. Residential In-Home daycare with not more than 12 children shall use interconnected single station detectors in all habitable rooms. Sec. 907.2.6; add new Section 907.2.6.4 to read as follows: Sec. 907.2.6.4 Group I-4 occupancies. An approved smoke detection system shall be installed in Group I-4 occupancies. Where automatic fire sprinklers are not provided, a full-coverage smoke detection system shall be provided in all Group I-4 occupancies. Sec. 907.2.10.1 is amended to read as follows, Exception to remain: Sec. 907.2.10.1 Public and self-storage occupancies. A manual fire alarm system that activates the occupant notification system in accordance with Section 907.5 shall be installed in Group S public- and self-storage occupancies for interior corridors and interior common areas. Visible notification appliances are not required within storage units. Sec. 907.2.13, exception 3 is amended to read as follows: 3. Buildings with an occupancy in Group A-5 in accordance with Section 303.1 of the International Building Code, when used for open air seating; however, this exception does not apply to accessory uses including but not limited to sky boxes, restaurants and similarly enclosed areas. Sec. 907.4.2; add new Section 907.4.2.7 to read as follows: Sec. 907.4.2.7 Type. Manual alarm actuating devices shall be an approved double action type. Sec. 907.5.2; add new Section 907.5.2.4 to read as follows: Sec. 907.5.2.4 I-2 and Group B occupancies. Occupant notification systems are not required where private mode fire alarm systems are needed in critical care areas of I-2 and Group B Ambulatory Occupancies. A Chime sound shall be used as the audible notification at the constantly attended location and public areas where audible notification is required. A visible alarm notification appliance installed in a nurses control station or other continuously attended staff location shall be provided as an acceptable alternative to the installation of audible alarm notification appliances throughout the occupancy. In areas where private mode fire alarm system is being installed, audible alarm notification appliances are not required in critical care areas of Group I-2 and Group B - Ambulatory Occupancies. Visible alarm notification appliances are not required in critical care areas of Group I-2 and Group B - Ambulatory Occupancies. The private mode area and public mode area of the occupancy shall be identified on the plans for review. Sec. 907.6.1; add new Section 907.6.1.1 to read as follows: Sec. 907.6.1.1 Wiring Installation. All fire alarm systems shall be installed in such a manner that a failure of any single initiating device or single open in an signaling line circuit conductor will not interfere with the normal operation of other such devices. All signaling line circuits (SLC) shall be installed in such a way that a single open will not interfere with the operation of any addressable devices (Class A). Outgoing and return SLC conductors shall be installed in accordance with NFPA 72 requirements for Class A circuits and shall have a minimum of four feet of separation horizontal and one foot vertical between supply and return circuit conductors. Notification appliance circuits (NAC) may be installed as Class B circuits. Sec. 907.6.3; is amended by deleting all four (4) exceptions. Sec. 907.6.3; add new Sections 907.6.3.2 and 907.6.3.3 to read as follows: Sec. 907.6.3.2 Communication Requirements. All alarm systems, new or replacement, shall transmit alarm, supervisory, and trouble signals descriptively to the approved central station, remote supervisory station or proprietary supervising station as defined in NFPA 72, with the device designation and location of addressable device identification. Alarms shall not be permitted to be transmitted as a General Alarm or Zone condition. Sec. 907.6.3.3 Flow detectors and electronic monitoring. Sprinkler and standpipe system water flow detectors shall be provided for each floor zone to the sprinkler system and shall cause an alarm upon detection of water flow for a minimum of 45 seconds and not more than 90 seconds. All control valves in the sprinkler and standpipe systems except for fire department hose connection valves shall be electrically supervised to initiate a trouble signal at the central station upon tampering. SECTION 910 SMOKE AND HEAT REMOVAL. Sec. 910.2; add new Section 910.2.3 to read as follows: Sec. 910.2.3 Group H. Buildings and portions thereof used as a Group H occupancy as follows: 1. In occupancies classified as Group H-2 or H-3, any of which are more than 15,000 square feet (1394m 2 ) in single floor area. Exception: Buildings of noncombustible construction containing only noncombustible materials. 2. In areas of buildings in Group H used for storing Class 2, 3 and 4 liquid and solid oxidizers, Class 1 and unclassified detonable organic peroxides, Class 3 and 4 unstable (reactive) materials, or Class 2 or 3 water-reactive materials as required for a high-hazard commodity classification. Exception. Buildings of noncombustible construction containing only noncombustible materials. Sec. 910.3.1 is amended by adding the following sentence: Gravity operated drop out vents are prohibited. SECTION 912.2 FIRE DEPARTMENT CONNECTIONS. Sec. 912.2; add new Section 912.2.3 to read as follows: Section 912.2.3 Hydrant distance. An approved fire hydrant shall be located within 100 feet of the fire department connection as the fire hose lays along an unobstructed path. Sec. 912.4.1 is amended to read as follows: Sec. 912.4.1 Locking Fire Department Connection Caps. All new fire department connections and existing where caps are missing shall be protected by Knox locking caps. SECTION 913 FIRE PUMPS. Sec. 913.2.1 is amended by adding the following paragraph and exception: Sec. 913.2.1: Protection of Fire Pump Room. When located on the ground level, the fire pump room shall be provided with an exterior fire department access door that is not less than 3 ft. in width and 6 ft. in height, regardless of any interior doors that are provided. A key box shall be provided at this door, as required by Section 506.1. Exception: When it is necessary to locate the fire pump room on other levels or not at an exterior wall, the corridor leading to the fire pump room access from the exterior of the building shall be provided with equivalent fire resistance as that required for the pump room, or as approved by the fire code official. Access keys shall be provided in the key box as required by Section 506.1. Sec. 913.4 is amended to read as follows: Sec. 913.4 Valve Supervision. Where provided, the fire pump suction, discharge and bypass valves, and the isolation valves on the backflow prevention devices or assembly shall be supervised open by a central-station, proprietary, or remote-station signaling service. The fire-pump system shall also be supervised for "loss of power", and "phase reversal" on supervisory circuits, and "pump running" as an alarm condition and shall report individually to the monitoring station. SECTION 915 CARBON MONOXIDE (CO) DETECTION. Sec. 915 delete all and replace as follows: Sec. 915.1 General. New and existing building shall be provided with carbon monoxide (CO) detection in accordance with Sections 915.2 through 915.5. Sec. 915.2 Where required. Carbon monoxide detection shall be provided in interior spaces, other than dwelling units, that are exposed to a carbon monoxide source in accordance with Sections 915.2.1 through 915.2.3. Carbon monoxide detection for dwelling units or sleeping units that are exposed to a carbon monoxide source shall be in accordance with Section 915.2.4. Sec. 915.2.1 Interior spaces with direct carbon monoxide sources. In all occupancies, interior spaces with a direct carbon monoxide source shall be provided with carbon monoxide detection located in close proximity to the direct carbon monoxide source and in accordance with Section 915.3. Exception: Where environmental conditions in an enclosed space are incompatible with carbon monoxide detection devices, carbon monoxide detection shall be provided in an approved adjacent location. Sec. 915.2.2 Interior spaces adjacent to a space containing a carbon monoxide source. In Groups A, B, E, I, M and R Occupancies, interior spaces that are separated from and adjacent to an enclosed parking garage or an interior space that contains a direct carbon monoxide source shall be provided with carbon monoxide detection if there are communicating openings between the spaces. Detection devices shall be located in close proximity to communicating openings on the side that is furthest from the carbon monoxide source and in accordance with Section 915.3. Exceptions: 1. Where communicating openings between the space containing a direct carbon monoxide source and the adjacent space are permanently sealed airtight, carbon monoxide detection is not required for the adjacent space. 2. Where the fire code official determines that the volume or configuration of the adjacent interior space is such that dilution or geometry would diminish the effectiveness of carbon monoxide detection devices located in such spaces, detection devices additional to those required by Section 915.2.1 shall be located on the side of communicating openings that is closest to the carbon monoxide source. Sec. 915.2.3 Interior spaces with forced-indirect carbon monoxide sources. In all occupancies, interior spaces with a forced-indirect carbon monoxide source shall be provided with carbon monoxide detection in accordance with either of the following: 1. Detection in each space with a forced-indirect carbon monoxide source, located in accordance with Section 915.3. 2. Detection only in the first space served by the main duct leaving the forced-indirect carbon monoxide source, located in accordance with Section 915.3, with an audible and visual alarm signal provided at an approved location. Sec. 915.2.4 Dwelling units and sleeping units. Carbon monoxide detection for dwelling units and sleeping units shall comply with Sections 915.2.4.1 and 915.2.4.2. Sec. 915.2.4.1 Direct carbon monoxide sources. Where a direct carbon monoxide source is located in a bedroom or sleeping room, or a bathroom attached to either, carbon monoxide detection shall be installed in the bedroom or sleeping room. Where carbon monoxide detection is not installed in bedrooms or sleeping rooms, carbon monoxide detection shall be installed outside of each separate sleeping area in close proximity to bedrooms or sleeping rooms for either of the following conditions: 1. The dwelling unit or sleeping unit has a communicating opening to an attached, enclosed garage. 2. A direct carbon monoxide source is located in the dwelling unit or sleeping unit outside of bedrooms or sleeping rooms. Sec. 915.2.4.2 Forced-indirect carbon monoxide sources. Bedrooms or sleeping rooms in dwelling units or sleeping units that are exposed to a forced-indirect carbon monoxide source shall be provided with carbon monoxide detection in accordance with Section 915.2.4.1 or Section 915.2.3. Sec. 915.3 Location of detection devices. Carbon monoxide detection devices shall be installed in accordance with manufacturer's instructions in a location that avoids dead air spaces, turbulent air spaces, fresh air returns, open windows, and obstructions that would inhibit accumulation of carbon monoxide at the detection location. Carbon monoxide detection in air ducts or plenums shall not be permitted as an alternative to required detection locations. Sec. 915.4 Permissible detection devices. Carbon monoxide detection shall be provided by a carbon monoxide detection system complying with Section 915.4.2 unless carbon monoxide alarms are permitted by Section 915.4.1. Sec. 915.4.1 Carbon monoxide alarms. Carbon monoxide alarms complying with Sections 915.4.1.1 through 915.4.1.3 shall be permitted in lieu of a carbon monoxide detection system in both of the following: 1. Dwelling units and sleeping units. 2. Locations other than dwelling units or sleeping units, where approved, provided that the manufacturer's instructions do not prohibit installation in locations other than dwelling units or sleeping units and that the alarm signal for any carbon monoxide alarm installed in a normally unoccupied location is annunciated by an audible and visual signal in an approved location. Sec. 915.4.1.1 Power source. In buildings with a wired power source, carbon monoxide alarms shall receive their primary power from a permanent connection to building wiring, with no disconnecting means other than for overcurrent protection, and shall be provided with a battery backup. In buildings without a wired power source, carbon monoxide alarms shall be battery powered. Exception: For existing buildings not previously required to have carbon monoxide alarms permanently connected to a wired power source, existing battery-powered and plug-in with battery backup carbon monoxide alarms shall be permitted to remain in service. When replaced, replacement with battery-powered and plug-in with battery backup carbon monoxide alarms shall be permitted. Sec. 915.4.1.2 Listings. Carbon monoxide alarms shall be listed in accordance with UL 2034. Combination carbon monoxide/smoke alarms shall also be listed in accordance with UL 217. Sec. 915.4.1.3 Interconnection. Where more than one carbon monoxide alarm is installed, actuation of any alarm shall cause all of the alarms to signal an alarm condition. Sec. 915.4.2 Carbon monoxide detection systems. Carbon monoxide detection systems shall be installed in accordance with NFPA 72. Sec. 915.4.2.1 Fire alarm system integration. Where a building fire alarm system or combination fire alarm system, as defined in NFPA 72, is installed, carbon monoxide detection shall be provided by connecting carbon monoxide detectors to the fire alarm system. Where a building fire alarm system or a combination fire alarm system is not installed, carbon monoxide detection shall be provided by connecting carbon monoxide detectors to a carbon monoxide detection system complying with NFPA 72. Sec. 915.4.2.2 Listings. Carbon monoxide detectors shall be listed in accordance with UL 2075. Combination carbon monoxide/smoke detectors shall be listed in accordance with UL 268 and UL 2075. Sec. 915.4.2.3 Alarm notification. For other than Group E Occupancies, activation of a carbon monoxide detector shall initiate alarm notification in accordance with any of the following: 1. An audible and visible alarm notification throughout the building and at the control unit. 2. Where specified in an approved fire safety plan, an audible and visible alarm in the signaling zone where the carbon monoxide has been detected and other signaling zones specified in the fire safety plan, and at the control unit. 3. Where a sounder base is provided for each detector, an audible alarm at the activated carbon monoxide detector and an audible and visible alarm at the control unit. For Group E Occupancies having an occupant load of 30 or less, alarm notification shall be provided in an on-site location staffed by school personnel or in accordance with the notification requirements for other occupancies. For Group E occupancies having an occupant load of more than 30, an audible and visible alarm shall be provided in an onsite location staffed by school personnel. Sec. 915.5 Maintenance. Carbon monoxide alarms and carbon monoxide detection systems shall be maintained in accordance with NFPA 72 and the manufacturer's instructions. Carbon monoxide alarms and carbon monoxide detectors that become inoperable or begin producing end-of-life signals shall be replaced. Sec. 1006.2.1; change Section 1006.2.1 "Egress based on occupant load and common path of egress travel distance" by amending Exception 3 to read as follows: 3. Unoccupied rooftop mechanical rooms and penthouses are not required to comply with the common path of egress travel distance measurement. Sec. 1006.2.2; change Section 1006.2.2 by adding a new Section 1006.2.2.7 to read as follows: Sec. 1006.2.2.7 Electrical Rooms. For electrical rooms, special exiting requirements may apply. Reference the electrical code, as adopted. Table 1010.2.4 Manual Bolts, automatic Flush Bolts and Constant Latching Bolts on the Inactive Leaf of a Pair of Doors; change amend Table by adding Group M and A occupancies to read as follows: Group M to Line item #1 in Table 1010.2.4: Group B, F, M or S occupancies with occupant load less than 50. [Remainder unchanged] Add Group A and M to Line item #2 in Table 1010.2.4: Group A, B, F, M or S occupancies where the building is equipped with an automatic sprinkler system in accordance with Section 903.3.1.1 and the inactive leaf is not needed to meet egress capacity requirements. [Remainder unchanged] Sec. 1020.2 Construction; change section to add a new Exception 6 to read as follows: 6. In unsprinklered Group B occupancies, corridor walls and ceilings need not be of fire-resistive construction within a single tenant space when the space is equipped with approved automatic smoke-detection within the corridor. The actuation of any detector must activate self-annunciating alarms audible in all areas within the corridor. Smoke detectors must be connected to an approved automatic fire alarm system where such system is provided. Sec. 1030.1.1.1 Spaces under grandstands and bleachers; delete the section in its entirety. Sec. 1101.1; change section to read as follows: Sec. 1101.1 Scope. The provisions of this chapter shall control the design and construction of facilities for accessibility for individuals with disabilities. Exception: Components of projects regulated by and registered with Architectural Barriers Division of Texas Department of Licensing and Regulation or regulated by and in compliance with the Fair Housing Act and Design Manual shall be deemed to be in compliance with the requirements of this chapter. Sec. 1106 Parking and Passenger Loading Facilities; delete the section in its entirety. Sec. 2702; change Section 2702 by adding a new Section 2702.5 to read as follows: Sec. 2702.5 Designated critical operations areas (DCOA). In areas within a facility or site requiring continuous operation for the purpose of public safety, emergency management, national security or business continuity, the power system shall comply with NFPA 70 Article 708. Sec. 2901.1; change section to read as follows: [P] 2901.1 Scope. The provisions of this chapter and the International Plumbing Code shall govern the design, construction, erection and installation of plumbing components, appliances, equipment and systems used in buildings and structures covered by this code. Toilet and bathing rooms shall be constructed in accordance with Section 1210. Private sewage disposal systems shall conform to the International Private Sewage Disposal Code. The International Fire Code, the International Property Maintenance Code and the International Plumbing Code shall govern the use and maintenance of plumbing components, appliances, equipment and systems. The International Existing Building Code and the International Plumbing Code shall govern the alteration, repair, relocation, replacement and addition of plumbing components, appliances, equipment and systems. The provisions of this chapter are meant to work in coordination with the provisions of Chapter 4 of the International Plumbing Code. Should any conflicts arise between the two chapters, the building official shall determine which provision applies. Sec. 2902.1; change section to read as follows: Sec. 2902.1 Minimum number of fixtures. Plumbing fixtures shall be provided in the minimum number as shown in Table 2902.1 based on the actual use of the building or space. Uses not shown in Table 2902.1 shall be considered individually by the code official. The number of occupants shall be determined by this code. In other than E occupancies, the minimum number of fixtures in Table 2902.1 may be lowered, if requested in writing, by the applicant stating reasons for a reduced number and approved by the building official. Table 2902.1; change table to add a footnote g to read as follows: TABLE 2902.1 - MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURES NO. | CLASSIFICATION | DESCRIPTION | WATER CLOSETS (URINALS: SEE SECTION 424.2) | LAVATORIES | BATH- TUBS/ SHOWERS | DRINKING FOUNTAINS (SEE SECTION 410) | OTHER MALE | FEMALE | MALE | FEMALE 2 | Business g | Buildings for the transaction of business, professional services, other services involving merchandise, office buildings, banks, ambulatory care, light industrial and similar uses | 1 per 25 for the first 50 and 1 per 50 for the remainder exceeding 50 | 1 per 40 for the first 80 and 1 per 80 for the remainder exceeding 80 | - | 1 per 100 g | 1 service sink e 6 | Mercantile g | Retail stores, service stations, shops, salesrooms, markets and shopping centers | 1 per 500 | 1 per 750 | - | 1 per 1,000 g | 1 service sink e g. Drinking fountains are not required in M occupancies with an occupant load of 100 or less, B occupancies with an occupant load of 25 or less, where drinking water is provided in a container free of charge. Sec. 2902.1; change section by adding new Sections 2902.1.4, 2902.1.4.1, and 2902.1.4.2 to read as follows: Sec. 2902.1.4 Additional fixtures for food preparation facilities. In addition to the fixtures required in this chapter, all food service facilities shall be provided with additional fixtures set out in this section. Sec. 2902.1.4.1 Hand washing lavatory. At least one hand washing lavatory shall be provided for use by employees that is accessible from food preparation, food dispensing and ware washing areas. Additional hand washing lavatories may be required based on convenience of use by employees. Sec. 2902.1.4.2 Service sink. In new or remodeled food service establishments, at least one service sink or one floor sink shall be provided so that it is conveniently located for the cleaning of mops or similar wet floor cleaning tool and for the disposal of mop water and similar liquid waste. The location of the service sink(s) and/or mop sink(s) shall be approved by the City of Plano Health Department. Sec. 3002.1; change to read as follows: Sec. 3002.1 Hoistway enclosure protection. A hoistway for elevators, dumbwaiters and other vertical-access devices shall comply with Sections 712 and 713. Where the hoistway is required to be enclosed, it shall be constructed as a shaft enclosure in accordance with 713. Refer to 712.1.10 for elevators in parking garages. Exceptions: Elevators completely located within atriums shall not require hoistway enclosure protection. Sec. 3005.4; change to read as follows: Sec. 3005.4 Machine rooms, control rooms, machinery spaces and control spaces. The following rooms and spaces shall be enclosed with fire barriers constructed in accordance with Section 707 or horizontal assemblies constructed in accordance with Section 711, or both: 1. Machine rooms. 2. Control rooms. 3. Control spaces. 4. Machinery spaces outside of the hoistway enclosure. The fire-resistance rating shall be not less than the required rating of the hoistway enclosure served by the machinery. Openings in the fire barriers shall be protected with assemblies having a fire protection rating not less than that required for the hoistway enclosure doors. Exceptions: 1. For other than FSAE and occupant evacuation elevators, elevator machine rooms, control rooms, machinery spaces and control spaces completely located within atriums shall not require enclosure protection. 2. For other than FSAE and occupant evacuation elevators, elevator machine rooms, control rooms, machinery spaces and control spaces in open or enclosed parking garages that serve only the parking garage, shall not require enclosure protection. Sec. 3005.5; change section by adding new Subsections 3005.5.1, 3005.5.1.1, 3005.5.1.1.1, 3005.5.1.1.2, 3005.5.1.2, and 3005.5.1.3 to read as follows: Sec. 3005.5.1 Fire protection in machine rooms, control rooms, machinery spaces and control spaces. Sec. 3005.5.1.1 Automatic sprinkler system. The building shall be equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1, except as otherwise permitted by Section 903.3.1.1.1 and as prohibited by Section 3005.5.1.1.1. Sec. 3005.5.1.1.1 Prohibited locations. Automatic sprinklers shall not be installed in machine rooms, elevator machinery spaces, control rooms, control spaces and elevator hoistways. Sec. 3005.5.1.1.2 Sprinkler system monitoring. The sprinkler system shall have a sprinkler control valve supervisory switch and water-flow initiating device provided for each floor that is monitored by the building's fire alarm system. Sec. 3005.5.1.2 Water protection. An approved method to prevent water from infiltrating into the hoistway enclosure from the operation of the automatic sprinkler system outside the elevator lobby shall be provided. Sec. 3005.5.1.3 Shunt trip. Means for elevator shutdown in accordance with Section 3005.5 shall not be installed. Sec. 3005; change section by adding a new Section 3005.7 to read as follows: Sec. 3005.7 Storage. Storage shall not be allowed within the elevator machine room, control room, machinery spaces and or control spaces. Provide approved signage at each entry to the above-listed locations stating: "No Storage Allowed." Sec. 3006.2; change section to read as follows: Sec. 3006.2 Hoistway opening protection required. Elevator hoistway door openings shall be protected in accordance with Section 3006.3 where an elevator hoistway connects more than three stories, is required to be enclosed within a shaft enclosure in accordance with Section 712.1.1 and any of the following conditions apply: 1. The building is not protected throughout with an automatic sprinkler system in accordance with Section 903.3.1.1 or 903.3.1.2. 2. The building contains a Group I-1, Condition 2 occupancy. 3. The building contains a Group I-2 occupancy. 4. The building contains a Group I-3 occupancy. 5. The building is a high rise and the elevator hoistway is more than 55 feet (16 764 mm) in height. The height of the hoistway shall be measured from the lowest floor at or above grade to the highest floors served by the hoistway. Sec. 3007.3; change section to read as follows: Sec. 3007.3 Water protection. Water from the operation of an automatic sprinkler system outside the lobby shall be prevented from infiltrating into the hoistway enclosure in accordance with an approved method. Sec. 3008.3; change section to read as follows: Sec. 3008.3 Water protection. Water from the operation of an automatic sprinkler system outside the lobby shall be prevented from infiltrating into the hoistway enclosure in accordance with an approved method.

(Ord. No. 2016-3-11, § II, 3-14-16; Ord. No. 2018-11-9, § II, 11-26-18, eff. 1-1-19; Ord. No. 2022-1-10, § II, 1-24-22; Ord. No. 2022-11-3, §§ I, II, 11-14-22; Ord. No. 2025-6-14, § II, 6-9-25; Ord. No. 2025-7-9, § I, 7-28-25)

Ask a question about Plano law

Corpus searches the Plano sections it holds and shows the ones that match, with their citations. Free, no sign-in.