For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 3.3 — Accessory Uses and Structures

Code of the City of Arlington, Texas (City Secretary chapter PDFs as posted 2026-11-07, each current through the ordinance named on its cover, with the City Secretary's adopted-not-yet-codified Ordinances 25-063, 25-069, 25-073, 25-074, 25-075, 25-084, 26-003, 26-004, 26-019, 26-024 and 26-027 applied; Anti-Discrimination chapter not included) · Arlington City Code, Unified Development Code Chapter, § 3.3

Corpus is an independent public-information project, not the official City of Arlington website. Stable reference: corpuslaw.us/code/88596a55-471f-4c28-829a-ebdf52bf3455

3.3. ACCESSORY USES AND STRUCTURES

3.3.1. PURPOSE This section authorizes the establishment of accessory uses and structures that are incidental and customarily subordinate to principal uses. An accessory use or structure is “incidental and customarily subordinate” to a principal use if it complies with the standards set forth in this section. All principal uses allowed in a zoning district shall be deemed to include those accessory uses, structures, and activities typically associated with the use, unless specifically prohibited in this section. Section 12.3, Definitions of General Use Categories and Specific Use Types, identifies typical accessory uses associated with principal uses as part of the principal use definition. 3.3.2. APPROVAL PROCEDURE A. Generally Any of the accessory uses identified in this section may be allowed as accessory to an authorized principal use provided that: 1. The proposed accessory use is allowed as a principal or accessory use in the base district or overlay district where proposed; and 2. The proposed accessory use or structure is consistent with the general and specific standards for accessory uses in this subsection. B. Simultaneously with a Principal Use Accessory uses or structures may be reviewed as part of review of an associated principal use. In cases where the principal use is subject to a Specific Use Permit, an accessory use may only be authorized in accordance with an approved Specific Use Permit. C. Subsequent to a Principal Use 1. Unless exempted, a building permit shall be required in cases where an accessory use or structure is proposed subsequent to a principal use. 2. In cases where the principal use is subject to a Specific Use Permit, an accessory use may only be authorized in accordance with the provisions in Section 10.4.6, Specific Use Permits. 3.3.3. INTERPRETATION OF UNIDENTIFIED ACCESSORY USES AND STRUCTURES The Zoning Administrator shall evaluate applications for accessory uses that are not identified in this section on a case-by-case basis, based on the following standards: A. The definition of "accessory use" in Article 12, Definitions, and the general accessory use standards and limitations established in Section 3.3.5; B. The purpose and intent of the base and overlay districts in which the accessory use is located; C. Potential adverse effects the accessory use or structure may have on other lots, compared with other accessory uses permitted in the district; and D. The compatibility of the accessory use with other principal and accessory uses permitted in the district. 3.3.4. USE TABLES FOR ACCESSORY USES AND STRUCTURES A. Accessory Uses – Residential Districts | TABLE 3.3-1: Accessory Uses – | Residential Districts P = Permitted Use | S = Specific Use Permit | * = Supplemental Standards Apply Use Type | RE | RS 20 | RS 15 | RS 7.2 | RS 5 | RM 12 | RMF 22 | VG | | Use Standards Accessory building (not listed below) | P* | P* | P* | P* | P* | P* | P* | P* | | 3.3.6.A Accessory use (not listed below) | P | P | P | P | P | P | P | P | | 3.3.6.A Alternative energy system | P* | P* | P* | P* | P* | P* | P* | P* | | 3.3.6.B Caretaker’s quarters | P* | | | | | | | P | | 3.3.6.C Carport | P* | P* | P* | P* | P* | | | P* | | 3.3.6.D Community center (private) | S | S | S | S | S | S | P | S | | 3.3.6.A Garage apartment | | | | | | P* | P* | | | 3.3.6.F Garage (private) | P | P | P | P | P | P | P | P | | 3.3.6.A Home-based business | P* | P* | P* | P* | P* | P* | P* | P* | | 3.3.6.H Secondary living unit | P* | P* | P* | S* | S* | S* | | P* | | 3.3.6.L Swimming pool (private) | P* | P* | P* | P* | P* | P* | P* | P* | | 3.3.6.P [image omitted; see the official code] [image omitted; see the official code] B. Accessory Uses – Non-Residential and Mixed-Use Districts | | | | TABLE 3.3-2: Accessory Uses – Non-Residential and | Mixed-Use Districts | | | | P = Permitted Use | S = Specific Use Permit | * = Supplemental Standards Apply Use Type | | LO | OC | NC | CC | GC | HC | BP | FH | LI | IM | NMU | RMU | Use Standards Accessory building (not listed below) | P* | P* | P* | P* | P* | P* | P* | P* | P* | P* | P* | P* | 3.3.6.A Accessory use (not listed below) | P* | P* | P* | P* | P* | P* | P* | P* | P* | P* | P* | P* | 3.3.6.A Alternative energy system | P* | P* | P* | P* | P* | P* | P* | P* | P* | P* | P* | P* | 3.3.6.B Caretaker’s quarters | | P | P | P | P | P | P | P | P | P | P | | | 3.3.6.C Community center (private) | | | | | | | | | | | | P | P Customarily incidental use | P | P | P | P | P | P | P | P | P | P | P | P | 3.3.6.E Electric vehicle charging station | P | P | P | P | P | P | P | P* | P | P | P | P | 3.3.6.O Garage apartment | | | | | | | | | | | | P | P | 3.3.6.F Garage (private) | | P* | P* | P* | P* | P* | P* | P | P* | P | P | P | P | 3.3.6.G Home-based business | | | | | | | | | | | | P* | P* | 3.3.6.H Mobile Food Establishment | | | P* | P* | P* | P* | P* | P* | P* | P* | P* | P* | P* | P* | 3.3.6.N [image omitted; see the official code] [image omitted; see the official code] [image omitted; see the official code] [image omitted; see the official code] [image omitted; see the official code] TABLE 3.3-2: Accessory Uses – Non-Residential and Mixed-Use Districts P = Permitted Use S = Specific Use Permit * = Supplemental Standards Apply Use Type | | LO | OC | NC | CC | GC | HC | BP | FH | LI | IM | NMU | RMU | Use Standards Outside display and sales | | | | P* | P* | P* | P* | P* | | P* | P* | P* | P* | 3.3.6.I Outdoor storage | | | | | P* | P* | P* | P* | | P* | P* | | | 3.3.6.J Recycling collection center | | | | | S* | S* | | | | P* | P* | | | 3.3.6.K Sidewalk cafe | | P* | P* | P* | P* | P* | P* | P* | P* | P* | P* | P* | P* | 3.3.6.M Swimming pool (private) | | | | | | | | | | | | P* | P* | 3.3.6.P Transit passenger shelter | | P | P | P | P | P | P | P | P | P | P | P | P 3.3.5. GENERAL STANDARDS FOR ALL ACCESSORY USES AND STRUCTURES All accessory uses and structures shall be subject to the general standards in this section, as well as any applicable supplemental standards in Section 3.3.6, Supplemental Accessory Use Standards and all standards applicable to the associated principal use as set forth in Section 3.2, Supplemental Use Standards. A. Size All accessory uses and structures shall: 1. Be clearly subordinate in area, extent, and purpose to the principal use or structure; and 2. Not violate the bulk, density, parking, landscaping, or open space standards of this Code when taken together with the principal use or structure. 3. The floor area of any detached accessory structure shall not exceed 50 percent of the floor area of the principal structure. The total combined floor area of all structures shall not exceed the maximum lot coverage for the zoning district in which it is located. The Zoning Administrator may authorize a structure to exceed this percentage if the structure is used as a guest house, or is used for animal production or crop production associated with an agricultural use. B. Function All accessory uses and structures shall directly serve the principal use or structure, and be accessory and clearly incidental to the principal use or structure. C. Timing Accessory uses and structures shall not be constructed or established prior to the start of construction of the principal use or structure. An accessory structure shall not be used until the construction of the primary structure is complete. D. Height Accessory structures shall be limited to a maximum height of 24 feet unless exempted from the height requirements in this Code. E. Location 1. Accessory uses or structures shall be located on the same lot as the principal use or structure. 2. Accessory structures shall not be located within platted or recorded easements. 3. The Zoning Administrator may authorize an accessory structure on a vacant lot if the structure is used for animal production or crop production associated with an agricultural use, or used in conjunction with a park or community garden. F. Design Compatibility 1. Except where exempted, all accessory structures shall be designed to be aesthetically compatible with the principal structure. Compatibility shall be measured in terms of building materials, building orientation, building placement, and building mass. Non-enclosed stables, gazebos, greenhouses, and carports ten feet or less in height with a roofed area of 300 square feet or less are exempted from this compatibility requirement. 2. Applicants for accessory structures not exempted in accordance with this subsection who request exceptions from the design compatibility requirements shall demonstrate screening methods or design features that will be used to minimize any potential adverse effects on neighboring properties. G. Ownership Accessory uses or structures shall be owned or operated by the same person as the principal use or structure. 3.3.6. SUPPLEMENTAL ACCESSORY USE STANDARDS A. Accessory Building 1. Uses a. In all residential districts, permitted accessory buildings include garages, storage sheds, gazebos, cabanas, storm shelters, and similar structures. An accessory building may be used for hobbies insofar as such activities are an accessory use only and are not offensive by reason of odor, noise, or manner of operation. Accessory buildings cannot be used for commercial or business purposes. b. In all non-residential, mixed-use districts, and form-based zoning districts (FBZDs), accessory buildings are permitted only for uses listed in the Public and Institutional Uses category, as identified in Table 3.1-2, Allowed Uses – Non-Residential and Mixed-Use Districts. 2. Residential Building Design The standards for exterior materials and appearance of the residential accessory building are based on the size (area and height) of the structure itself and are set forth in Table 3.3-3, below. TABLE 3.3-3: Residential Accessory Building Design Standards Floor Area/ Wall Height | Exterior walls | Roof | Foundation A. | Less than or equal to 200 square feet in floor area | Less than or equal to 8 feet in wall height | Any approved building material | Any approved roofing material | No requirements Greater than 8 feet in wall height | Any approved building material, except for metal | No metal,(standing seam metal allowed if present on primary structure). Any other approved roofing material | No requirements B. | More than 200 square feet but less than 550 square feet in floor area | All wall heights | Any approved building material, except for metal | No metal,(standing seam metal allowed if present on primary structure). Any other approved roofing material. Roof pitch shall be compatible with the roof pitch of the primary residence. | As required by the Construction Chapter of the Arlington Code of Ordinances C. | 550 square feet or larger in floor area | All wall heights | As required by Section 5.5.3.C.5, Exterior Finish Materials | No metal,(standing seam metal allowed if present on primary structure). Any other approved roofing material. Roof pitch shall be compatible with the roof pitch of the primary residence. | As required by the Construction Chapter of the Arlington Code of Ordinances The exterior appearance of an accessory structure shall be architecturally compatible with the primary residence, including but not limited to coordination of architectural style, exterior building materials and colors, roof form and pitch, and window style and placement. 3. Setbacks and Number of Buildings a. Front setback Enclosed accessory buildings, such as a storage building or storm shelter, shall not be located between the front property line and an imaginary building line drawn from each front corner of the main building to the side property line. b. Side and Rear Setback An accessory building shall be located a minimum of five feet from side and rear property lines, except as provided below. (i) A minimum setback of 15 feet is required from the side property line adjacent to a street on a corner or reverse corner lot. The setback may be reduced to ten feet when a side screening fence is installed per Section 5.3.4, Single-Family Residential Fencing. (ii) A minimum setback of 20 feet is required from the rear property line adjacent to an arterial or collector street identified on the Thoroughfare Development Plan. The setback may be reduced to five feet if the accessory structure is no taller than eight feet in wall height and is 200 square feet in area or smaller. (iii) For parcels within or immediately abutting residential single-family districts, the minimum interior side yard and rear yard setbacks for an accessory building with a wall height greater than 8 feet shall be increased as follows: (1) Two additional feet of setback for wall heights up to 10 feet. (2) Thereafter, two additional feet of setback for each additional one foot of wall height above 10 feet. (3) Wall height shall be measured from the natural grade at the abutting property line. (4) In no case shall the highest point of the roof of the accessory building exceed the height of the primary structure, regardless of grade. c. Number of Accessory Buildings The maximum number of accessory buildings allowed per lot shall be in accordance with Table 3.3-4. TABLE 3.3-4: Number of Accessory Buildings Lot Size | Less than 1 acre | 1 acre and larger Number of Buildings, max. | 3 buildings | 5 buildings B. Alternative Energy System Permitted alternative energy systems include solar energy systems, small wind energy systems, geoexchange systems, and geothermal direct heat systems. 1. Solar Energy System Standards All solar energy systems shall comply with the following requirements: a. Ground-Mounted System Setbacks, [image omitted; see the official code] Location, and Height (i) Ground-mounted solar energy systems shall not be located in the front yard between the principal structure and the public right-of-way. (ii) A ground-mounted solar energy Figure 3.1 Ground-mounted solar systems shall be located a minimum energy system. of ten feet from all property lines and other structures. (iii) A ground-mounted solar energy system is not permitted as a primary use of a property. The size of a ground-mounted solar energy system in any residential district shall not exceed 600 square feet. The size of ground-mounted solar energy systems in non-residential and mixed-use districts shall not exceed one-half of the footprint of the principal structure. (iv) Ground-mounted solar energy systems shall not exceed 12 feet in height in a residential zone district, or 20 feet in height in a non-residential zone district. (v) Excluding solar collection panels, their necessary support structure, and conduits, all equipment related to a ground-mounted solar energy system shall comply with Section 5.3.2 Mechanical and Utility Equipment Screening. b. Building-Mounted System Setbacks, Location, and Height (i) A building-mounted solar energy system shall be located a minimum of six feet from all property lines and other structures, except the structure on which it is mounted. (ii) Building-mounted solar energy system panels shall be located only on rear- or side-facing elevations as viewed from any adjacent street. The Zoning Administrator may approve an alternate location if the owner demonstrates that, due to solar access limitations, no other location exists where the system can perform effectively. (iii) A building-mounted solar energy [image omitted; see the official code] system shall not extend more than the maximum height permitted in the zoning district in which it is located. (iv) A building-mounted solar energy system may be located on an accessory structure, such as a patio Figure 3.2 Building-mounted solar cover or detached garage. energy system Excluding solar collection panels, their necessary support structure, and conduits, all equipment related to a building-mounted solar energy system shall comply with Section 5.3.2 Mechanical and Utility Equipment Screening c. Code Compliance All solar energy systems shall comply with all applicable building, construction, and electrical codes adopted by the City. 2. Small Wind Energy System Standards Small wind energy systems may be horizontal axis or vertical axis systems, and shall comply with the following requirements: a. Residential District Requirements (i) A maximum of one small wind energy system is permitted per lot or one per acre, whichever is greater. (ii) The maximum height for a small wind energy system shall not exceed 75 feet measured from the base of the tower to the highest point on the tower. Systems taller than 75 feet shall be subject to the specific use permit process set forth in Section 10.4.6, Specific Use Permits. (iii) Building-mounted small wind energy systems shall not exceed 40 feet in height measured from the base attached to the structure to the highest point on the tower. (iv) A small wind energy system shall be setback a distance of 1.0 times its total height from: (1) Any public road right-of-way, unless written permission is granted by the governmental entity with jurisdiction over the road; (2) Any overhead utility lines, unless written permission is granted by the affected utility; and (3) All property lines, unless written permission is granted from the affected land owner or neighbor. b. Non-Residential District Requirements Multiple small wind energy systems are permitted on any non-residential lot subject to the following requirements: (i) The maximum height for a small wind energy system shall not exceed 75 feet measured from the base of the tower to the highest point on the tower. (ii) Building-mounted small wind energy systems shall not exceed 40 feet in height measured from the base attached to the structure to the highest point on the tower. (iii) Lightpole mounted small wind energy systems shall not exceed 25 feet in height measured from the top of the lightpole to the highest point on the tower. (iv) A small wind energy system shall be setback a distance of 1.0 times its total height from: (1) Any public road right-of-way, unless written permission is granted by the governmental entity with jurisdiction over the road; (2) Any overhead utility lines, unless written permission is granted by the affected utility; and (3) All property lines, unless written permission is granted from the affected land owner or neighbor. c. General Standards for Small Wind Energy Systems (i) Lighting A small wind energy system shall not be artificially lighted unless such lighting is required by the Federal Aviation Administration. A light temporarily used to inspect a turbine, tower, and associated equipment is permissible, provided said light is only used for inspection purposes and not left on for an extended period. (ii) Decibel Levels Decibel levels for a small wind energy system shall not exceed 60 decibels (Dba) as measured at the closest neighboring inhabited dwelling, except during short-term events such as utility outages and severe wind storms. (iii) Glare Small wind energy systems shall be sited to prevent shadow flicker or blade glint upon any inhabited structure, except for the owner’s, or public roadway. (iv) Signs All signs, other than the manufacturer’s or installer’s identification, appropriate warning signs, or owner identification on a wind generator, tower, building, or other structure associated with a small wind energy system visible from any public road shall be prohibited. (v) Code Compliance A small wind energy structure, including the tower, shall comply with all applicable state and City construction and electrical codes. (vi) Screening Ground-level mechanical equipment associated with the small wind energy system shall conform to the utility screening standards of Section 5.3.2, Mechanical and Utility Equipment Screening. (vii) Equipment Access All ground-mounted electrical and control equipment shall be labeled or secured to prevent unauthorized access. (viii) Other Standards The structure shall comply with all applicable Federal Aviation Administration requirements, including but not limited to Subpart B (commencing with Section 77.11) of Part 77 of Title 14 of the Code of Federal Regulations regarding installations in excess of 200 feet in height and installations close to airports. The system shall also comply with all Texas aeronautics regulations. (1) All electrical wires associated with a small wind energy system shall be located underground, except for wires necessary to connect the wind generator to the tower wiring, the tower wiring to the disconnect junction box, and the grounding wires. (2) A small wind energy system tower shall be designed and installed so that step bolts or a ladder are not readily accessible to the public for a minimum height of 8 feet above the ground. (3) No part of the system, including guy wire anchors, may be closer than five feet from any property boundary. (4) Meteorological (Met) towers shall be permitted under the same standards as a small wind energy system. d. Repair and Removal of Small Wind Energy Systems The repair and/or removal of small wind energy systems are subject to the following: (1) Any device found to be unsafe by the Zoning Administrator shall immediately cease operation upon notification, and the device shall be repaired by the owner to meet federal, state, and local safety standards, or be removed within six months. Wind devices that are not operated for a continuous period of 12 months shall be removed by the owner of the device. (2) When a wind device is removed from a site, all associated and ancillary equipment, batteries, devices, structures or supports for that system shall also be removed. For the purposes of this section, non-operation shall be deemed to include, but shall not be limited to, the blades of the wind device remaining stationary so that wind resources are not being converted into electric or mechanical energy, or the wind device is no longer connected to the public utility electricity distribution system. 3. Geoexchange System Standards Geoexchange systems shall comply with the following requirements: a. Closed System A geoexchange system shall be “closed-loop”, meaning it shall be designed so that it does not remove or introduce any fluid into the ground, groundwater, or any body of water. b. Loop Configuration A geoexchange system may be of vertical or horizontal loop configuration so long as it does not penetrate any aquifer. The loop may be placed into a pond or other body of surface water provided that the entire body of water is under the ownership and control of the property owner. c. Antifreeze To avoid possible contamination in the event of a system failure, the use of antifreeze is discouraged within a geoexchange system, and shall be limited to glycol or another similar ecologically benign substance. 4. Geothermal Direct Heat System Standards Geothermal direct heat systems shall comply with the following requirements: a. Proof of Permits Required A building permit for a geothermal direct heat system shall not be issued by the City until the applicant submits proof that all required local, regional, state, and federal permits (for drilling of wells, etc.) have been secured. b. Performance Heat, vibration, steam, or other emissions from a geothermal direct heat system shall not be detectable on nearby commercial or residential property, nor shall the steam create an impediment to visibility within any airport approach or departure zone. C. Caretaker’s Quarters 1. Caretaker’s quarters may be permitted as an accessory use provided the structure: a. Is oriented towards side or rear yard of the primary structure; and b. Shall not contain more than one bedroom, more than one kitchen, or more than one bathroom. 2. The owner shall sign and record restrictive covenants limiting use of the accessory dwelling unit prior to the issuance of a building permit. D. Carports in Required Front Yards 1. Purpose and Applicability The purpose of this provision is to allow carports to be erected within the required front yard when no other feasible option exists on the qualifying residential lots. Carports in the required front yard shall be limited to lots where the principal structure was originally constructed before January 31, 1984. 2. Approval Carports may be permitted in required front yards of certain single-family residential lots where the Zoning Administrator determines that the proposed carport: a. Is in keeping with the existence, location, and design of other carports in the immediate vicinity of the requested carport; b. Will not cause sight obstructions to motorists on or entering the abutting neighborhood; c. Will not cause a negative visual impact on the streetscape of the neighborhood; d. Is compatible with the architectural style of the dwelling and the predominant architectural style of the neighborhood; and e. There are no recorded and active covenants and/or restrictions that apply to the subject property and/or surrounding neighborhood that would prohibit the proposed carport. 3. Design Any carport that is permitted to occupy a portion of the required front yard shall comply with the following restrictions: a. Freestanding carports that are not structurally integrated with the roof of the principal structure shall not exceed 18 inches of separation from the principal structure. b. Except for the roof, carports shall be painted to match or replicate the color of the trim areas of the principal structure. c. Carports shall have a pitched roof that matches the existing pitch of the principal structure and that utilizes shingles that substantially match the color of the shingles used on the principal structure. The roof of the carport shall be either a closed gable or hip design. The Zoning Administrator may approve an alternate design to satisfy this requirement. d. Carports shall have dimensions no greater than 20 feet in length by 20 feet in width for lots with principal structures originally designed with two-car garages, and/or no greater than 10 feet in width for lots with principal structures originally designed with single-car garages. e. No portion of a carport structure shall be nearer to the side lot lines than the principal structure, or five feet, whichever is the greater distance from the side lot line. f. The minimum height of a support structure for the carport shall be eight feet. The overall height of the carport shall not exceed the height of the primary structure. All heights shall be measured from the highest ground elevation at the wall of the carport. g. All sides of a carport that are within the required front yard shall be open and unobstructed, except for support columns, which in total shall not obstruct more than 15 percent of the area of any side. h. The entire area under a carport shall only be used to park operable and properly licensed vehicles (i.e., cars, pickup trucks, vans, sport utility vehicles, boats, campers, etc.) that are customarily incidental to the residential use of the property. No storage of household belongings or other non-vehicle items are allowed. i. Carports shall only be permitted when covering an appropriate all-weather driveway surface (i.e. concrete or asphalt) designed for vehicle storage. E. Customary Incidental Use In all districts, a customary incidental use shall be determined by the Zoning Administrator. F. Garage Apartment In the RM-12, RMF-22, NMU, and RMU districts, an accessory garage apartment shall be counted as a dwelling unit for purposes of calculating density on the site. G. Garage, Private 1. In the LO, OC, NC, CC, GC, HC and FH districts: a. The garage shall be for use by a business owner or manager, and is not intended for customers or storage; and b. Vehicle storage is limited to not more than five motor vehicles. 2. In the DT-FBZ-Core, NMU, and RMU districts, the garage shall be used by a business owner, manager, or customers, and is not intended for general public use. H. Home-Based Business A home occupation may be permitted as accessory to any principal dwelling unit in all residential districts, and the FBZ-TN and RMU districts, subject to the following standards: 1. Location The home-based business shall be conducted in the house by a resident of the primary dwelling. 2. Size and Area The business or service located within the dwelling shall not exceed 25 percent of the floor area of the house. Activities are limited to the living portion of a house or its attached garage. Accessory buildings or detached structures cannot be used in conjunction with a home-based business. 3. Employees and Residency The principal person(s) providing the business or service shall reside in the dwelling on the premises. Only one additional employee, other than the resident(s) of the primary dwelling unit, is permitted at the home-based business at any one time. 4. Neighborhood Compatibility a. The home-based business shall cause no change in the external appearance of the existing buildings and structures on the property. b. All vehicles used in connection with the home-based business shall be of a size, and located on the premises in such a manner, so that a casual observer or a person of normal sensibilities will not be able to detect any sign of the premises being used as a home occupation. No vehicle larger than one ton shall be kept on the premises. c. Parking of vehicles to accommodate off-site employees or permitted customers shall be limited to the driveway of such premises or along the curb immediately adjacent to such premises. d. There shall be no advertising devices on the property or other signs of the home-based business that are visible from off the premises, other than advertising located on vehicles in accordance with Article 7, Sign Standards. e. The property shall contain no outdoor display of goods or services that are associated with the home occupation. Outside storage is prohibited. For the purpose of this section, the parking of one trailer in a driveway or along the street curb is not considered outside storage. f. Wholesale or retail sales of goods shall not occur on the premises. g. The home-based business shall not create traffic or parking congestion, noise, vibration, odor, glare, fumes, or electrical or communications interference that can be detected by the normal senses off the premises, including visual or audible interference with radio or television reception. All home based businesses are subject to the “Nuisance”, “Fire Prevention”, “Animals”, and other applicable chapters of the Code of the City of Arlington. 5. Prohibited Home-based Businesses The following uses, because of their effects on the surrounding residential area, shall not be permitted as home-based businesses: auto repair or motorized implement repair; dance, music or other types of tutoring instruction where more than four students are being instructed at one time; dental offices; medical offices; the painting of vehicles, trailers or boats; private schools with organized classes; motor vehicle towing operation; barber or beauty shops having more than one chair; welding shops; nursing homes; bed and breakfast and other such transient lodging; or any other home-based business that, in the sole opinion of the Zoning Administrator, will have negative effects on the neighborhood. 6. Incidental Use Subject to Termination A home-based business is permitted as an incidental use and is secondary to the use of a dwelling. As such, the City Council may amend this ordinance at any time to terminate any or all home-based business uses without creating nonconforming rights to the continuance of a home based business. 7. Annual Registration No residence shall be allowed to operate a home-based business until the Building Official or a designee has issued an annual Registration Certificate. The issuance of a Certificate requires that an applicant affirm knowledge of, and intent to comply with all ordinances applicable to home based businesses. The Building Official, or a designee, shall establish that the proposed use is allowable under the terms of the ordinance. The issuance of a Certificate shall not authorize any violations of the Code of the City of Arlington. Violations may result in the revocation or non-renewal of Certificates thereby terminating the home based business. I. Outside Display and Sales 1. In all districts: a. The use is not permitted within street frontage building setbacks or any landscape buffer yard required by Section 5.2, Landscaping. b. Limited to no more than five percent of building area containing the main use. c. Outside display of finished products for a time period exceeding one day may be permitted by the Zoning Administrator where, in addition to 1.a and 1.b: (i) The products are screened pursuant to Section 5.3, Screening, Buffering, and Fences; (ii) The display is limited to the minimum number of units necessary to demonstrate the use of a product; (iii) The display is not located within any required side or rear setback; and (iv) The display does not pose any threat to public health or welfare and does not violate any City or state law related to public health or welfare. J. Outside Storage 1. In the BP, CC, GC, FBZ-CMU, and HC districts: a. The use is not permitted within street frontage building setback or any transitional buffer yard required by this Code. b. Outside storage areas not screened by an intervening building shall be screened from view of any public street right-of-way by a screening device at least eight feet in height. In addition, outside storage areas must be screened from view of any adjoining property by a screening device at least eight feet in height, except along adjacent property lines zoned LI or IM. Said screening device shall not be constructed from corrugated metal or chain link fencing material. c. No materials stored shall be stacked above the top of the screening device. Items extending beyond the top of the screening device are permitted provided they are not stacked. d. Outside storage is limited to no more than 5% of the lot area containing the main use. 2. In the LI and IM districts: a. The use is not permitted within street frontage building setback or any transitional buffer yard required by this Code. b. Outside storage areas not screened by an intervening building shall be screened from view of any public street right-of-way by a screening device at least eight feet in height. In addition, outside storage areas must be screened from view of any adjoining property by a screening device at least eight feet in height, except along adjacent property lines zoned LI or IM. Said screening device shall not be constructed from corrugated metal or chain link fencing material. c. No materials stored shall be stacked above the top of the screening device. Items extending beyond the top of the screening device are permitted provided they are not stacked. d. Along major thoroughfares, a minimum fence setback of 50 feet shall apply. e. Along all other streets, a minimum fence setback of 25 feet shall apply. f. The screening standards included herein shall not apply to sites within core industrial areas, as determined by the Zoning Administrator. g. In the LI district, outside storage is limited to no more than 40% of the lot area containing the main use. h. In the IM district, outside storage is limited to no more than 75% of the lot area containing the main use, unless the lot is located in an ED or DN overlay, in which case outside storage is capped at 40% of the lot area containing the main use. K. Recycling Collection Center 1. In the CC and GC districts, can banks existing on June 28, 1995, are exempt from these requirements, but remain under any conditions approved with the original Special Exception. 2. In the LI and IM districts: a. A recycling collection center located on a parking lot may not occupy required off-street parking spaces, and it must be located so as to not impede free traffic flow. b. The owner of the property and the owner and operator of the recycling collection center shall: (i) remove products stored at the recycling collection center at least once a week; (ii) keep the recycling collection center in proper repair and maintain a neat and clean exterior appearance; and (iii) keep the building site clean and in a neat appearance, and dispose of material and other litter from the building site where the recycling collection center is located. c. In the CC and GC districts: (i) A recycling collection center may only be located in an enclosed trailer less than 50 feet in length situated on a parking lot. (ii) A recycling collection center may only be placed on a parking lot of a site containing a building of 50,000 square feet or more of floor area. Not more than one recycling collection center is permitted on a lot. (iii) A recycling collection center located on a parking lot may not occupy required off-street parking spaces, and it must be located so as not to impede free traffic flow. (iv) Receipt of and payment for material at a recycling collection center may take place at a point no more than 20 feet from the opening of the enclosed trailer where the products are stored. (v) The owner of the property and the owner and operator of the recycling collection center shall: (1) remove products stored at the recycling collection center at least once a week; (2) keep the recycling collection center in proper repair and maintain a neat and clean exterior appearance; and (3) keep the building site clean and in a neat appearance, and dispose of material and other litter from the building site where the recycling collection center is located. L. Secondary Living Unit In all districts, this use shall be permitted under the following conditions: 1. The structure must meet all standards as applied to the primary structure except the requirement for minimum gross living area, the requirement for a garage or carport, and the off-street parking requirements. 2. The structure must not contain more than one bedroom, more than one kitchen, or more than one bathroom. 3. Only one secondary living unit is allowed per lot and that secondary living unit shall count towards the maximum number of accessory buildings allowed per lot in accordance with Table 3.3-4. M. Sidewalk Cafe In all districts in which a sidewalk café is allowed, occupancy of a public sidewalk or parkway for a sidewalk café shall be permitted under the following conditions: 1. Use of a public sidewalk is subject to approval of an easement or right-of-way use agreement by the Zoning Administrator. 2. The area of occupancy must be abutting and contiguous to the restaurant in which food preparation, sanitation, and related services for the sidewalk cafe will be performed. 3. A sidewalk cafe may not be enclosed by fixed fencing or other structures, unless necessary to comply with requirements to serve alcohol. 4. A sidewalk cafe must be open to the air; however, it may be covered with a canopy. 5. There shall be a six-foot wide unimpeded sidewalk remaining for pedestrian flow from the face of the curb and the area of temporary occupancy. 6. The sidewalk café shall be located a minimum of five feet from driveways and alleys, and ten feet from intersections. 7. All curbs, alleys, sidewalks, and public rights-of-way adjacent to such sidewalk café shall be kept in a clean and orderly condition. N. Mobile Food Establishment 1. A mobile food establishment shall only be permitted in the following use districts: DT-FBZ-CMU, DT-FBZ-Core, and DT-FBZ-Gateway districts. Provided, that the accessory use shall only exist concurrently with a certificate of occupancy permitted in said zoning use districts with an underlying land use for one of the following: a. Restaurant; b. Bar; c. Microbrewery, microdistillery, or winery; and d. Theatre. If the underlying land use ceases to operate for any reason, the certificate of occupancy for the mobile food establishment operating in connection with the property shall expire automatically without any formal action required by the City. O. Electric Vehicle Charging Stations and Signage 1. No audio, video displays, or digital advertising signage, other than the branding of the EV charging unit, shall be permitted. 2. There shall be no reduction in handicap accessible parking spaces to accommodate installation of EV charging stations. 3. The charging station shall be capable of charging electric vehicles produced by multiple manufacturers. P. Swimming Pools Swimming Pools shall not be located between the front property line and an imaginary building line drawn from each front corner of the main building to the side property line.

Amended by Ord. No. 26-019, passed 4-21-2026.

Ask a question about Arlington law

Corpus searches the Arlington sections it holds and shows the ones that match, with their citations. Free, no sign-in.