CFR
/
Title 46 — Shipping
/
Chapter I — Coast Guard, Department of Homeland Security
/
Subchapter J — Electrical Engineering
/
Part 111 — Electric Systems—General Requirements
/
Subpart 111.55 — Switches
Circuit connections.
46 C.F.R. § 111.55-3
in effect
☆ Save this law
Sign in to generate a plain English summary
Ask Belisarius Agent
The load side of each circuit must be connected to the fuse end of a fused-switch or to the coil end of a circuit breaker, except a generator which is connected to either end of a circuit breaker.