§ 15.14.650 — Maintenance and operation of grease control devices
San José Municipal Code (Supp. No. 5: codified through Ordinance No. 31341, enacted August 25, 2026) · San José Municipal Code § 15.14.650
Corpus is an independent public-information project, not the official City of San Jose website. Stable reference: corpuslaw.us/code/8a789833-2817-46a9-a231-02a193c07acf
15.14.650 - Maintenance and operation of grease control devices.
A. Grease control devices shall be maintained in efficient operating condition by periodic removal of the accumulated grease. The use of chemicals, bacteria, enzymes, or other additives that have the effect of emulsifying or dissolving grease is prohibited unless specifically authorized by the director in writing. No accumulated grease shall be introduced into any drainage piping or public or private sewer. B. Grease control devices shall be cleaned on a sufficient frequency to prevent objectionable odors, surcharge of the grease control device, or interference with the operation of the sanitary sewer system. 1. Grease traps shall be cleaned at least once every thirty days. 2. Grease interceptors shall be cleaned once every ninety days. 3. Mechanical grease removal devices must be maintained in a manner and frequency consistent with manufacturer specifications and guidance. 4. Grease control devices shall be cleaned when their last chamber is filled to twenty- five percent or more of capacity with grease or settled solids. Grease interceptors with a sample box shall be shall be cleaned immediately when grease is evident in the sample box. 5. Grease control devices shall be cleaned by being pumped dry and all accumulated sludge on all surfaces shall be removed by washing down the sides, baffles and tees. No water removed from the device during cleaning shall be returned to the grease control device. C. The director may grant an exception to the requirements of Subsections B.1 and B.2 where the director finds, based on evidence presented by the discharger, that a less frequent cleaning schedule will be sufficient to assure that not more than twenty-five percent of the capacity of the grease control device will be filled with grease or settled solids. D. All dischargers shall implement best management practices in their operations to minimize the discharge of grease to the sanitary sewer system. E. Dischargers shall maintain records on site for a period of at least three years as follows: 1. Dischargers with an installed grease control device shall maintain records showing that the grease control device has been properly maintained and cleaned as required by Subsections A. and B.; and 2. Food service establishments shall maintain records showing the following related to all grease hauled off site: date and time material removed off site; volume removed; hauler name; truck license number, type of grease removed, and final destination of material collected. F. Abandoned grease control devices shall be emptied and filled as required for abandoned septic tanks.
(Ord. 28537.)
Ask a question about San Jose law
Corpus searches the San Jose sections it holds and shows the ones that match, with their citations. Free, no sign-in.