18.40.590 - Amend CBC Section 2308.10.8.1—Foundation requirements.
Section 2308.10.8.1 of the California Building Code is amended to read as follows: 2308.10.8.1 Foundation requirements. Braced wall lines shall be supported by continuous foundations. Exception: For structures with a maximum plan dimension not over 50 feet (15,240 mm), continuous foundations are required at exterior walls only for structures assigned to Seismic Design Category A, B or C. For structures in Seismic Design Categories D and E, exterior braced wall panels shall be in the same plane vertically with the foundation or the portion of the structure containing the offset shall be designed in accordance with accepted engineering practice and Section 2308.3.
(ORD-25-0019 § 1(Exh. A), 2025)