Sec. 49-506. - Fixture openings installed for future use.
The following provisions shall be observed: (a) Dwelling units, restaurants, food preparation areas and any building designated with sleeping quarters: (1) A future use fixture opening shall be permitted in a soil or waste pipe only if a vent is provided. (2) A future use fixture opening shall be securely plugged, tested and inspected. (b) Open-air shopping centers, strip malls, storefronts or commercial buildings with retail or office space in which the shell is constructed and the interior tenant space will be finished at a later date: (1) Vent piping for future soil or waste openings will not be required to be installed at the time of the rough-in and may be installed at the tenant finish, only if the distance from the building drain or stack does not exceeded the distance stated in section 49-504. (2) A vent stack or vent opening shall be located within 60 feet developed length from the future fixture opening. (3) The fixture opening shall be securely plugged at the floor line, tested and inspected.
(Ord. No. 40524, § 1, 10-20-15)