Sec. 6-31. - Amendments to International Building Code (IBC).
(a) Appendices adopted. Appendix [appendices] C, D and I of the International Building Code, 2021 Edition, are adopted and Appendix [appendices] A, B, E, F, G, H, J, K, L, M, N, and O are deleted.
(b) Section 105.2.1 Emergency Permits is hereby amended to read as follows:
"In an emergency caused by fire, flood, tornado or other natural or manmade disaster, the chief building official, or his representative, may issue a permit prior and inspect to receiving the required application and permit fee. However, information required on the application under section 105 of this code must be provided to the chief building official when the emergency permit is requested. Any person, firm, or corporation obtaining an emergency permit shall, within five (5) working days after the issuance of such emergency permit, remit to the chief building official at the inspection department, fees in the amount required for such permit, together with written application, required under section 105 of this code. If such fees are not paid within five (5) days, a double fee shall be charged."
(c) Section 105.3.2 and Section 105.5 are hereby amended to exclude sign permits.
(d) Section 111.2 is amended to add subsection 111.2.1 as follows:
"Sec. 111.2.1 The chief building official shall also require approvals and consents to the certificate of occupancy by city departments and other agencies to the extent the occupancy, use, or nature would impact the department or agency's operations or regulations. Any such city department or agency may withhold their consent and/or approval to a certificate of occupancy unless and until the occupancy, nature or use thereof conforms to its respective ordinances or regulations. Said certificate of occupancy shall not be issued until all required electrical, gas, mechanical, plumbing and fire protection systems have been inspected for compliance with the technical codes and other applicable laws and ordinances and released by the chief building official."
(e) Section 1809.8 is amended to add the following:
"Plain concrete footings supporting walls shall be provided with not less than two continuous longitudinal reinforcing bars or other approved methods. Reinforcing bars shall not be smaller than #4. Continuity of reinforcing bars shall be provided at corners and intersections."
(f) Section 3107 is amended to add subsection 3107.2, 3107.3 and 3107.4 as follows:
"Sec. 3107.2 The governing body of the city may impose a moratorium on the issuance of any permits for erection of off-site outdoor advertising display signs. This moratorium may be imposed by resolution, duly adopted by the governing body of the city upon a finding that such moratorium is in the best interest of the city. Any moratorium imposed pursuant to this section shall be for a period not to exceed sixty (60) days. Any off-site outdoor advertising display sign erected without first obtaining a permit therefore shall be considered unlawful and subject to the provisions of section 3107.
Sec. 3107.3 is added as follows: The commencement of construction as it relates to a valid sign permit begins with the inspection of the footings.
Sec. 3107.4 is added as follows: An application for a sign permit shall be deemed to have been abandoned if construction has not commenced within three (3) months after the filing of a sign permit application. No extensions shall be granted for a sign permit application."
(g) Section 115.2 is amended to read as follows:
"The stop work order shall be in writing and posted on the property and where possible shall be given to the owner of the property involved or the owner's agent or to the person doing the work or to the person to whom the building permit was issued. Upon issuance of a stop work order, the cited work shall immediately cease. The stop work order shall state the reasons for the order, and conditions under which the cited work will be permitted to resume. Any person who shall continue any work in violation of a stop work order shall be subject to penalties as prescribed by law."
(h) Section 115.4 is added as follows:
"Whenever the chief building official or planning director finds any work regulated by the Tuscaloosa Building Code, the Code of Tuscaloosa or subdivision regulations being performed in a manner either contrary to the provisions thereof or dangerous or unsafe, the chief building official is authorized to issue a stop work order."
(i) Section 113 is amended to add subsections 113.4, 113.5, 113.6, and 113.7 as follows:
"113.4 Membership. The Board of Appeals will consist of nine (9) members: two (2) registered Architects, one (1) registered Engineer, two (2) licensed General Contractors, two (2) licensed Home Builders and two (2) at large positions.
113.5 Term. Board members shall be appointed to six year terms. Vacancies for unexpired terms to be filled for the remainder of the unexpired term. A board member whose term has expired shall continue to serve until a successor is appointed.
113.6 Quorum. A simple majority of the board will constitute a quorum.
113.7 Notice of Appeal. Notice of appeal shall be in writing and filed with the chief building official within 30 calendar days after the decision is rendered by the chief building official."
(j) Any sections in the 2021 International Building Code referring to the 2021 International Energy Conservation Code for requirements, is amended to substitute the current adopted State of Alabama Energy Code in place of the 2021 International Energy Conservation Code.
(k) Section 1206.3 Structure-Borne Sound is amended to read as follows:
"1206.3 Structure-Borne Sound. Floor-ceiling assemblies between dwelling units and sleeping units or between a dwelling unit or sleeping unit and a public or service area within the structure shall have an impact insulation class rating of not less than 50 where tested in accordance with ASTM E492, or have a Normalized Impact Sound Rating (NISR) of not less than 45 if field tested in accordance with ASTM E1007. Alternatively, the impact insulation class of floor-ceiling assemblies shall be established by engineering analysis based on a comparison of floor-ceiling assemblies having impact insulation class ratings as determined by the test procedures in ASTM E492.
Exception: Floor/ceiling assemblies between a dwelling unit or sleeping unit and a public or service area shall not be required to have an impact insulation rating."
(Code 1962, § 10-26; Ord. No. 2212, §§ 12, 13, 8-24-82; Ord. No. 2351, §§ 12, 13, 8-20-85; Ord. No. 2824, § 15, 8-2-88; Ord. No. 3422, § 22, 6-11-92; Ord. No. 6558, 12-18-03; Ord. No. 6745, § 1, 4-26-05; Ord. No. 7065, § 1, 5-8-07; Ord. No. 7257, § 1, 5-27-08; Ord. No. 7540, 5-25-10; Ord. No. 7594, 10-5-10; Ord. No. 8336, 1-19-16; Ord. No. 8820, § 27, 6-4-19; Ord. No. 9161, 1-11-22)