§ 21-0102 — Modification of International Building Code
Fargo Municipal Code, Fargo, North Dakota (Supp. No. 14, Update 5: codified through Ordinance No. 5555, adopted August 17, 2026) · Fargo Municipal Code § 21-0102
Corpus is an independent public-information project, not the official City of Fargo website. Stable reference: corpuslaw.us/code/8b88695c-5438-4fca-8ee1-3265553fda75
21-0102. - Modification of International Building Code.
The International Building Code as adopted in § 21-0101 is hereby changed and amended as follows: Section 101.1 is hereby amended to read as follows: 101.1 Title. These regulations shall be known as the Building Code of the City of Fargo, hereinafter referred to as "this code." Section 101.4.3 is hereby amended to read as follows: 101.4.3 Plumbing. The provisions of the North Dakota State Plumbing Code shall apply to the installation, alteration, repair and replacement of plumbing systems, including equipment, appliances, fixtures, fittings and appurtenances, and where connected to a water or sewage system and all aspects of a medical gas system. The provisions of the North Dakota State Plumbing Code shall apply to private sewage disposal systems. Section 103.1 is hereby amended to read as follows: 103.1 Creation of enforcement agency. The Inspections Department is hereby created and the official in charge thereof shall be known as the building official. The function of the agency shall be the implementation, administration and enforcement of the provisions of this code. Section 104.8.1 is hereby amended to read as follows: 104.8.1 Legal Defense. Any suit or criminal complaint instituted against an officer or employee because of an act or omission performed by that officer or employee in the lawful discharge of duties and under the provisions of this code or other laws and ordinances implemented through the enforcement of this code shall be afforded all the protection provided by the city's insurance pool and immunities and defenses provided by other applicable state and federal laws and shall be defended by legal representatives of the jurisdiction until the final termination of the proceedings. The building official or any subordinate shall not be liable for costs in any action, suit or proceeding that is instituted in pursuance of the provisions of this code. This code shall not be construed to relieve from or lessen the responsibility of any person owning, operating or controlling any building or structure for any damages to persons or property caused by defects, nor shall the code enforcement agency or the city be held as assuming any such liability by reason of the inspection authorized by this code or any permits or certificates issued under this code. Section 105.2 is hereby amended to read as follows: 105.2 Work exempt from permit. Exemptions from permit requirements of this code shall not be deemed to grant authorization for any work to be done in any manner in violation of the provisions of this code or any other laws or ordinances of this jurisdiction. Permits shall not be required for the following: Building: * * * * 2. Fences not over 8.5 feet high. * * * * 6. Sidewalks and driveways. * * * * 11. Swings and other playground equipment. 12. Window awnings. * * * * 14. Reroofing. Section 107.2.6.1 is hereby deleted in its entirety. Section 107.3.1 is hereby amended to read as follows: 107.3.1 Approval of construction documents. When the building official issues a permit, the construction documents shall be approved, in writing or by stamp. One set of construction documents so reviewed shall be retained by the building official. Section 109.2 is hereby amended to read as follows: 109.2 Schedule of permit fees. Where a permit is required, a fee for each permit and plan review shall be paid as required, in accordance with the schedule as established by the Board of City Commissioners. The plan review fees specified in this subsection are separate from, and in addition to, permit fees. When submittal documents are incomplete or changed so as to require additional plan review or when the project involves deferred submittal items as defined in Section 107.3.4.1, an additional plan review fee shall be charged in an amount not to exceed 10% of the building permit fee established in Section 109.2. Section 305.2 is hereby amended to read as follows: 305.2 Group E, day care facilities. This group includes buildings and structures or portions thereof occupied by more than twelve children older than 2 ½ years of age who receive educational, supervision or personal care services for fewer than 24 hours per day. Section 305.2.2 is hereby amended to read as follows: 305.2.2 Twelve or fewer children. A facility having twelve or fewer children receiving such day care shall be classified as part of the primary occupancy. Section 305.2.3 is hereby amended to read as follows: 305.2.3 Twelve or fewer children in a dwelling unit. A facility such as the above within a dwelling unit and having twelve or fewer children receiving such day care shall be classified as a Group R-3 occupancy or shall comply with the International Residential Code. Section 308.5 is hereby amended to read in part as follows: 308.5 Institutional Group I-4 day care facilities. Institutional Group I-4 occupancy shall include buildings and structures occupied by more than twelve persons of any age who receive custodial care for fewer than 24 hours per day by persons other than parents or guardians; relatives by blood, marriage or adoption; and in a place other than the home of the person cared for. This group shall include, but not be limited to, the following: Adult day care Child day care Section 308.5.1 is hereby amended to read in part as follows: 308.5.1 Classification as a Group E. A child day care facility that provides care for more than twelve but not more than 100 children 2 ½ years or less of age, where the rooms in which the children are cared for are located on a level of exit discharge serving such rooms and each of these child care rooms has an exit door directly to the exterior, shall be classified as Group E. Section 308.5.3 is hereby amended to read as follows: 308.5.3 Twelve or fewer persons receiving care. A facility having twelve or fewer persons receiving custodial care shall be classified as part of the primary occupancy. Section 308.5.4 is hereby amended to read as follows: 308.5.4 Twelve or fewer persons receiving care in a dwelling unit. A facility such as the above within a dwelling unit having twelve or fewer persons receiving custodial care shall be classified as a Group R-3 occupancy or shall comply with the International Residential Code. Section 406.3.2.1 is hereby amended to read as follows: 406.3.2.1 Dwelling unit separation. The private garage shall be separated from the dwelling unit and its attic area by means of gypsum board, not less than 1/2 inch (12.7 mm) in thickness, applied to the garage side. Garages beneath habitable rooms shall be separated from all habitable rooms above by not less than a 5/8-inch (15.9 mm) Type X gypsum board or equivalent and 1/2-inch (12.7 mm) gypsum board applied to structures supporting the separation from habitable rooms above the garage. Door openings between a private garage and the dwelling unit shall be equipped with either solid wood doors or solid or honeycomb core steel doors not less than 13/8 inches (34.9 mm) in thickness, or doors in compliance with Section 716.2.2.1 with a fire protection rating of not less than 20 minutes. Section 903.3.1 is hereby amended to read as follows: 903.3.1 Standards. Automatic sprinkler systems shall be designed with a 5 psi safety margin and installed in accordance with Section 903.3.1.1 unless otherwise permitted by Sections 903.3.1.2 and 903.3.1.3 and ither chapters of this code, as applicable. Section 903.3.1.1.1 is hereby amended to read as follows: 903.3.1.1.1 Exempt locations. * * * * 6. Elevator machine room and machinery spaces. Where sprinklers are not installed in elevator machine rooms, shunt trip required in accordance with IBC 3005.5 shall not be installed. Section 903.3.5 is hereby amended to read as follows: 903.3.5 Water supplies. Water supplies for automatic sprinkler systems shall comply with this section and the standards referenced in Section 903.3.1. The potable water supply shall be protected against backflow in accordance with the requirements of this section and the International Plumbing Code. For connections to public waterworks systems, the water supply test used for design of fire protection systems shall be adjusted to account for seasonal and daily pressure fluctuations based on information from the water supply authority and as approved by the fire code official. Underground water supply piping shall be constructed of a material allowed by Fargo Municipal Code Chapter 16 and Chapter 22 and shall be allowed to extend into the building through the slab or wall not more than 24 inches. Section 905.1 is hereby amended to add an exception to read as follows: Exception: The installation of fire hose on standpipes may be omitted when approved by the local fire code official. Approved standpipe hose valves and connections shall be provided where required. Section 907.2.11.1 is hereby amended to read as follows: 907.2.11.1 Group R-1. Single- or multiple-station smoke alarms shall be installed in all of the following locations in Group R-1: * * * * 4. In sleeping units where the ceiling height of a room open to the hallway serving the sleeping rooms exceeds that of the hallway by 24 inches or more, smoke alarms shall be installed in the hallway and in the adjacent room. Section 907.2.11.2 is hereby amended to read as follows: 907.2.11.2 Groups R-2, R-3, R-4 and I-1. Single- or multiple station smoke alarms shall be installed and maintained in Groups R-2, R-3, R-4 and I-1 regardless of occupant load at all of the following locations: * * * * 4. In dwelling units where the ceiling height of a room open to the hallway serving the sleeping room exceeds that of the hallway by 24 inches or more, smoke alarms shall be installed in the hallway and in the adjacent room. Section 1003.3.1 is hereby amended as follows: 1003.3.1 Headroom. * * * * An approved barrier shall be provided where the vertical clearance above a circulation path is less than 80 inches (2032 mm) high above the finished floor. A portion of such a barrier shall be located 27 inches (686 mm) maximum above the finished floor. Section 1009.8.1 is hereby amended to read as follows: 1009.8.1 System requirements. Two-way communication systems shall provide communication between each required location and the fire command center or a central control point location approved by the fire department. Where the central control point is not a constantly attended location, the two-way communication system shall have timed, automatic telephone dial-out capability that provides two-way communication with an approved supervising station. The two-way communication system shall include both audible and visible signals. Section 1011.1 exception is hereby amended to read as follows: Exceptions: 1. Within rooms or spaces used for assembly purposes, stepped aisles shall comply with Section 1030. 2. In B, F, M, S or U occupancies, a stairway that is private and not open to the public that serves an area of 750 square feet or less, shall have a maximum riser height of 8 inches, a minimum thread depth of 9 inches, a minimum width of 36 inches, and shall have at least one handrail that terminates at the top and bottom riser. All other requirements of section 1014 shall apply. Section 1011.5.2 exceptions are hereby amended to read as follows: Exceptions: * * * * 3. In Group R-3 occupancies; within dwelling units in Group R-2 occupancies not required by Chapter 11 to be Accessible or Type A dwelling or sleeping units; and in Group U occupancies that are accessory to a Group R-3 occupancy or accessory to individual dwelling units in Group R-2 occupancies; the maximum riser height shall be 8 inches (203.2 mm); the minimum tread depth shall be 9 inches (228.6 mm); the minimum winder tread depth at the walkline shall be 10 inches (254 mm); and the minimum winder tread depth shall be 6 inches (152mm). A nosing projection not less than ¾ inch (19.1 mm) but not more than 1 ¼ inches (32 mm) shall be provided on stairways with solid risers where the tread depth is less than 11 inches (279 mm). * * * * 6. Stairways used only to attend equipment or private stairways serving an occupant load of 10 or fewer persons and which are not accessible to the public are permitted to have a maximum 8-inch riser height and minimum 9 tread depth. Section 1015.2 is hereby amended to read as follows: 1015.2 Where required. Guards shall be located along open-sided walking surfaces, including mezzanines, equipment platforms, aisles, stairs, ramps and landings, that are located more than 30 inches (762 mm) above the floor or grade below or if within 36 inches (914 mm) horizontally to the edge of the open side, the vertical measurement to the floor or grade below is greater than 48 inches. Guards shall be adequate in strength and attachment in accordance with section 1607.9. Section 1104.4 exceptions are hereby amended to read as follows: Exceptions: 1. An accessible route is not required to stories, mezzanines and occupied roofs that have an area of not more than 3,000 square feet (278.7 m 2 ), or are in a building 2 stories or less above grade plane and are located above or below accessible levels. This exception shall not apply to: * * * * Section 1202.1 is hereby amended to read as follows: 1202.1 General. Buildings shall be provided with natural ventilation in accordance with Section 1202.5, or mechanical ventilation in accordance with the International Mechanical Code. Section 1206 is hereby deleted in its entirety. Section 1403.6 is hereby deleted in its entirety. Section 1403.7 is hereby deleted in its entirety. Section 1601.1 is hereby amended to read as follows: 1601.1 Scope. The provisions of this chapter shall govern the structural design of buildings, structures and portions thereof. It shall not be the responsibility of the building official to determine engineering requirements of this code. Exclusive of the conventional light-frame wood construction provisions referenced in Section 2308, the method to resist loads as referenced in this chapter is the responsibility of a structural engineer or other qualified design professional. Section 1610.1 exception is hereby amended to read as follows: Exception: Foundation walls extending not more than 9 feet below grade and laterally supported at the top by flexible diaphragms shall be permitted to be designed for active pressure. Section 1804.4 is hereby deleted in its entirety and the following text enacted: Section 1804.4 Site Grading. Surface drainage shall be diverted to a storm sewer conveyance or other approved point of collection. Lots shall be graded to drain surface water away from foundation walls. The procedure used to establish the final ground level adjacent to the foundation shall account for additional settlement of the backfill. Section 1809.5 exception is hereby amended to read as follows: Exception: Free-standing unheated buildings used as Group U or S occupancies for the storage of private or pleasure-type motor vehicles constructed in accordance with Sections 406.1 and 406.3 meeting all of the following conditions shall not be required to be protected: 1. Assigned to Risk Category I. 2. Eave height of 20 feet or less. 3. Building is not normally occupied. Section 2901.1 is hereby amended to read as follows: Section 2901.1 Scope. The provisions of this chapter and the North Dakota State Plumbing Code shall govern the design, construction, erection and installation of plumbing components, appliances, equipment and systems used in buildings and structures covered by this code. Toilet and bathing rooms shall be constructed in accordance with Section 1210. Private sewage disposal systems shall conform to the North Dakota State Plumbing Code. The International Fire Code, the International Property Maintenance Code and the North Dakota State Plumbing Code shall govern the use and maintenance of plumbing components, appliances, equipment and systems. The International Existing Building Code and the North Dakota State Plumbing Code shall govern the alteration, repair, relocation, replacement and addition of plumbing components, appliances, equipment and systems. Section 2902.3 is hereby amended to add the following exception: Section 2902.3 Employee and public toilet facilities. * * * * Exception: Public toilet facilities shall not be required for: * * * * 3. Unheated self-storage facilities that are not staffed.
Source: 5347 (2022), 5375 (2022), 5486 (2025).
Ask a question about Fargo law
Corpus searches the Fargo sections it holds and shows the ones that match, with their citations. Free, no sign-in.