§ 13-112-290 — Dry cleaning building
Municipal Code of Chicago (2026 S-74, current through Council Journal of June 17, 2026) · Municipal Code of Chicago § 13-112-290
Corpus is an independent public-information project, not the official City of Chicago website. Stable reference: corpuslaw.us/code/8b8d34aa-bbb5-45fd-a120-3036ed3c2d16
13-112-290 Dry cleaning building.
Every room in a dry cleaning building in which a flammable solvent having a flash point below 140 degrees Fahrenheit (closed cup tester) is used shall be provided with an exit directly to the outside of the building. Every door to such a room shall open outward. Any stairway for such a building shall be a smokeproof tower or exterior stairway. There shall be no window or ventilating opening within five feet of any such stairway. An open balcony or runway leading to a stairway shall be considered as such means of exit, but there shall be no window or ventilating opening upon or below such balcony. (Prior code § 60-29)
Ask a question about Chicago law
Corpus searches the Chicago sections it holds and shows the ones that match, with their citations. Free, no sign-in.
