Sec. 34-232. - Smoke-detection devices; requirements.
(a) Installation required. (1) Dwellings. All structures and dwellings shall be equipped with smoke detectors and fire protection equipment as required by the provisions of chapter 4 and the city's building code. (2) Unlawful acts: In addition to and not in lieu of any other provisions of this section and of this Code, it shall be unlawful for any person responsible for the installation of a smoke detector to fail to so install it. It shall be unlawful for any person to tamper with, damage or render inoperative, such as, but not exclusively, by disconnecting electrical wiring or by removing the batteries from any smoke detector. (b) Type of detection devices. Detection devices shall be of the photo-electric or ionization type and shall be electric, 110 volts, alternating current, or battery-powered smoke detectors, Underwriters' Laboratory or Factory Mutual Approved. (1) Electric units shall be direct-wired on a separate circuit on the line side of service equipment, immediately fused with proper size fuse. Detector wiring shall be minimum 14 gauge wire. All wiring shall comply with the National Electric Code and shall be performed by registered, licensed electricians. (2) Battery-powered units shall be permitted only in structures built prior to 1983 or not substantially renovated since 1983. Where battery-powered units are permitted, the battery shall be of the type approved for the detector and shall provide a minimum of 12 months' service. Battery-powered units shall be equipped with an audible sounding device to alert occupants of the need for battery replacements. In rental dwelling units where battery-powered devices are permitted, after installation of the detection device at the landlord's expense, in accordance with subsection (a) of this section, it shall be the tenant's responsibility, unless otherwise provided in the tenant's lease agreement, to: a. Make periodic inspections of the unit to determine that it is in proper working order; b. Notify the landlord of any malfunction of such detection device which the landlord shall then repair or replace at his own expense; and c. Replace the batteries when necessary during the entire term of the rental agreement. (c) Audible signal. Detection devices shall be equipped with an audible sounding device that provides a steady signal with a minimum decibel rating of 85 decibels. (d) Number of devices required. A minimum of one device shall be required in one-story and two-story single-family dwelling units. Dwelling units consisting of three or more stories shall be equipped with a minimum of two devices. Buildings containing two or more dwelling units shall be equipped with a minimum of one device for each individual dwelling unit. The minimum requirement of this section is that one detector shall be installed on the first floor level at or near the stairs leading to the second floor level, or one detector shall be placed at the second floor level at or near the top of the stairs. In dwellings having basements or cellars, an additional smoke detector shall be installed at or near the top of the stairs leading from the basement or cellar to the first floor level. This section shall not limit the number of detectors required in residential buildings, where the design, arrangement or configuration of the interior would require additional detectors in additional areas of the protected premises, when in the judgment of the authority having jurisdiction, placement of additional detectors is necessary for the protection of the occupants. (e) Authority having jurisdiction. The commissioner of licenses and inspections and the fire marshal shall have concurrent jurisdiction for purposes of enforcing compliance with this section. The authority vested in the commissioner of licenses and inspections for enforcement of the provisions of the housing and building codes for purposes of conformity with the provisions of this section may be delegated to the office of the fire marshal. (f) Supervision of enforcement. All general contractors, subcontractors and their agents who install electric, 110-volt alternating-current powered smoke-detection devices shall be registered with the office of the city fire marshal in order to sell, distribute, furnish or install smoke-detection equipment within the city. It shall be the responsibility of the contractor, installer, or seller of electrical 110-volt, alternating current-powered smoke detectors to certify in writing to the commissioner of licenses and inspections that such device is in compliance with this section. This subsection shall not apply to persons who perform the actual installation of smoke detectors in dwelling units they own; however, such installations shall still require any applicable inspections required by the building code.
(Code 1968, § 34-41.1; Ord. No. 92-053(sub 1), § 21(b), 7-2-92; Ord. No. 21-006(sub 1), § 1, 2-18-21)
Ask a question about Wilmington law
Corpus searches the Wilmington sections it holds and shows the ones that match, with their citations. Free, no sign-in.