Sec. 44-241. - Glare control.
All luminaires shall be of the IES "full cutoff" type where zero candela intensity occurs at an angle of 90 degrees above nadir, and all greater angles from nadir. Additionally, the candela per 1,000 lamp lumens shall not numerically exceed 100 or ten percent at an angle of 80 degrees above nadir. This applies to all lateral angles around the luminaire. Notwithstanding this section, noncutoff type luminaires contained in or under canopies over gasoline dispensing units located at convenient stores, service stations or other commercial establishments dispensing gasoline and other commercial fuels shall be allowed. Such noncutoff type luminaires shall however, be subject to all other provisions of this division. Shields may be installed on any non-conforming luminaire to comply with this division. Luminaires that do not exceed 100 watts shall be permitted as non- cutoff fixtures.
(Ord. No. 36203, § 2, 3-25-03; Ord. No. 37243, § 2, 12-13-05)