Sec. 43-305. - Special requirements for boarding and rooming house occupancies.

The following special requirements must be met: (a) No occupied units are permitted in the basement. (b) No attic spaces may be occupied unless provided with an approved fire rated stair enclosure on the exterior of the building. (c) Occupied sleeping rooms shall be a minimum of 70 square feet per single occupant, 50 square feet for each additional occupant of the same room. (d) A full time monitored fire alarm system shall be installed and operational at all times. (e) Fire alarm pull stations shall be provided in all hallways of sleeping rooms and at all exit locations. (f) All exit locations in common areas must be clearly identified with illuminated exit signs. (g) Emergency egress lighting with a battery backup must be installed as per manufacturer's instructions in order to provide a minimum of one foot candle illumination three feet above the floor. (h) All sleeping rooms shall have a minimum of one egress window meeting the minimum 5.7 square feet size and one egress door. (i) All sleeping rooms and common areas shall be divided by a one-hour rated wall consisting of a minimum two × four wall framing and a single layer of ⅝ type "x" drywall applied to each side, taped and painted. (j) An operational smoke detector shall be installed and maintained in each sleeping room and all common areas. All smoke detectors must be hard wired and interconnected. (k) Entry doors to each room must be self-closing 20 minute rated doors with lever lockset hardware. (l) All existing boarding and rooming house occupancies shall install an NFPA approved 13R fire sprinkler system within two years of the application for license, in addition to the alarm system. (m) All proposed boarding and rooming house occupancies, not currently in operation as a boarding or rooming house, shall meet all the requirements set forth in this article prior to the submission of the application. (n) No boarding or rooming house shall be located within 750 feet of anther boarding or rooming house.

(Ord. No. 40326, § 1, 4-21-15)

Ask a question about Omaha law

Corpus searches the Omaha sections it holds and shows the ones that match, with their citations. Free, no sign-in.