§ 5-121.244 — Technical amendments to the Florida Building Code, Building
Code of Ordinances, City of Tampa (Supp. No. 148: codified through Ordinance No. 2025-152, enacted December 18, 2025) · Tampa City Code § 5-121.244
Corpus is an independent public-information project, not the official City of Tampa website. Stable reference: corpuslaw.us/code/8d667d94-6bb4-48ac-9c78-590f5f106898
Sec. 5-121.244. - Technical amendments to the Florida Building Code, Building.
1. Amend Chapter 2, Section 202 Definitions, as follows: SUBSTANTIAL DAMAGE. Damage of any origin sustained by a structure whereby the cost of restoring the structure to its before-damaged condition would equal or exceed fifty (50) percent of the market value of the structure before the damage occurred. The term also includes flood-related damage sustained by a structure on two separate occasions during a ten-year period for which the cost of repairs at the time of each such flood event, on average, equals or exceeds twenty-five (25) percent of the market value of the structure before the damage occurred. SUBSTANTIAL IMPROVEMENT. Any combination of repair, reconstruction, rehabilitation, alteration, addition or other improvement of a building or structure taking place during a one-year period, the cumulative cost of which equals or exceeds fifty (50) percent of the market value of the structure before the improvement or repair is started. For each building or structure, the one-year period begins on the later date of approved final inspection on trade permits or on the date the certificate of completion or certificate of occupancy is issued for projects that require plan review. If the structure has sustained substantial damage, any repairs are considered substantial improvement regardless of the actual repair work performed. The term does not, however, include either: 1. Any project for improvement of a building required to correct existing health, sanitary or safety code violations identified by the building official and that is the minimum necessary to assure safe living conditions. 2. Any alteration of a historic structure provided that the alteration will not preclude the structure's continued designation as a historic structure. 2. Amend Chapter 16, Section 1612 Flood Loads, as follows: 1612.4.1 Reserved. 1612.4.3. Modification of ASCE 24 Chapter 4 ASCE 24 Chapter 4 provisions that permit backfilled stem walls in Coastal A Zones shall not apply in the City of Tampa.
(Ord. No. 2024-15, § 2(Exh. A), 2-1-2024)
Ask a question about Tampa law
Corpus searches the Tampa sections it holds and shows the ones that match, with their citations. Free, no sign-in.