Sec. 49-1805. - Water softeners residential.
Residential water softeners shall have a minimum flow rate of 15 gallons per minute and meet NSF Standard #44. Additionally, the following provisions shall be followed:
(a) Softeners shall have sufficient rated softening capacity to allow at least three days between regenerations.
(b) The minimum softener capacity shall be 15,000 grains.
(c) Installation on a private water supply requires attention to operating pressure, as well as pump and well capacity, to assure proper operation.
(d) Softeners shall be sized according to the following occupancy demands:
(1) Hot water only softened: 25 gallons per person per day.
(2) All water softened (excluding water to toilets): 45 gallons per person per day.
(3) All water softened (including water to toilets): 60 gallons per person per day.
(e) When the occupancy of the home is unknown, sizing shall be based on the number of bedrooms as follows:
Number of Bedrooms | Number of People
2 | 3
3 | 5
4 | 6
5 | 7
6 | 8
(f) Water fixture units shall be considered when sizing so that the flow rate through the softener will be sufficient. See sections 49-1531, 49-1532 and 49-1533 for water fixture units.
(Ord. No. 40524, § 1, 10-20-15)