§ 30-0106 — Standards adopted
Fargo Municipal Code, Fargo, North Dakota (Supp. No. 14, Update 5: codified through Ordinance No. 5555, adopted August 17, 2026) · Fargo Municipal Code § 30-0106
Corpus is an independent public-information project, not the official City of Fargo website. Stable reference: corpuslaw.us/code/8e7163ad-b666-4de5-b92a-d44757b248e4
30-0106. - Standards adopted.
The following standards are hereby adopted for all heating, air conditioning and other gas, oil, or coal consuming appliances: A. All heating, air conditioning, or other gas, oil, or coal consuming appliances for either domestic or commercial use installed in the city of Fargo shall bear a seal of approval from the American Gas Association, American Standards Association, Underwriters Laboratories, or other nationally recognized testing laboratory. B. The International Mechanical Code, sponsored by the International Code Council, 2024 Edition, is hereby adopted as the mechanical code for the city of Fargo from the date on which this ordinance shall take effect, the provisions thereof shall be controlling within the limits of the city, and within the extra-territorial zoning jurisdiction of the city, with the following amendments: Section 101.1 is hereby amended to read as follows: 101.1 Title. These regulations shall be known as the Mechanical Code of the City of Fargo, hereinafter referred to as "this code." Section 103.1 is hereby amended to read as follows: 103.1 Creation of agency. The City of Fargo Inspections Department is hereby created and the official in charge thereof shall be known as the code official. The function of the agency shall be the implementation, administration and enforcement of the provisions of this code. Section 104.8 is hereby amended to read as follows: 104.8 Liability. The code official, member of the board of appeals or employee charged with the enforcement of this code, while acting for the jurisdiction in good faith and without malice in the discharge of the duties required by this code or other pertinent law or ordinance, shall not thereby be rendered personally liable, either civilly or criminally, and is hereby relieved from personal liability for any damage accruing to persons or property as a result of an act or by reason of any an act or omission in the discharge of official duties. This code shall not be construed to relieve from or lessen the responsibility of any person owning, operating, or controlling any building or structure for any damages to persons or property caused by defects, nor shall the code enforcement agency or the city be held as assuming any such liability by reason of the inspection authorized by this code or any permits or certificates issued under this code. Section 108.2 is hereby amended to read as follows: 108.2 Schedule of permit fees. Where work requires a permit, a fee for each permit and mechanical work shall be paid as required, in accordance with the schedule as established by the City of Fargo Board of City Commissioners. Section 201.3 is hereby amended to read as follows: 201.3 Terms defined in other codes. Where terms are not defined in this code and are defined in the International Building Code, International Fire Code, International Fuel Gas Code or North Dakota State Plumbing Code, such terms shall have meanings ascribed to them as in those codes. Section 307.2.2 is hereby amended to read as follows: 307.2.2 Drain pipe materials and sizes. Components of the condensate disposal system shall be ABS, cast iron, copper and copper alloy, CPVC, cross-linked polyethylene, galvanized steel, PE-RT, polyethylene, polypropylene, PVC or PVDF pipe or tubing. Components shall be selected for the pressure and temperature rating of the installation. Joints and connections shall be made in accordance with the applicable provisions of North Dakota State Plumbing Code relative to the material type. Condensate waste and drain line size shall be not less than ¾-inch pipe size and shall not decrease in size from the drain pan connection to the place of condensate disposal. Where the drain pipes from more than one unit are manifolded together for condensate drainage, the pipe or tubing shall be sized in accordance with Table 307.2.2. Section 701.3 is hereby added to read as follows: 701.3 Attic space. Attic space shall not be used for combustion air. Section 908.5 is hereby amended to read as follows: 908.5 Water supply. Cooling towers, evaporative coolers and fluid coolers shall be provided with an approved water supply, sized for peak demand. The quality of water shall be provided in accordance with the equipment manufacturer's recommendations. The piping system and protection of the potable water supply system shall be installed as required by the North Dakota State Plumbing Code. Section 1008.2 is hereby amended to read as follows: 1008.2 Discharge. Blowoff valves shall discharge to a safe place of disposal. Where discharging to the drainage system, the installation shall conform to the North Dakota State Plumbing Code. Section 1208.1 is hereby amended to read as follows: 1208.1 General. New hydronic piping systems shall be isolated and tested hydrostatically at no less than 100 psi (689 kPa). The duration of each test shall be not less than 15 minutes.
Source: 5350 (2022), 5491 (2025).
Ask a question about Fargo law
Corpus searches the Fargo sections it holds and shows the ones that match, with their citations. Free, no sign-in.