§ 49-730 — Space requirement for non-handicapped plumbing fixtures
Omaha Municipal Code (Supp. No. 100, Update 2: codified through Ordinance No. 44760, enacted August 4, 2026) · Omaha Municipal Code § 49-730
Corpus is an independent public-information project, not the official City of Omaha website. Stable reference: corpuslaw.us/code/8e7c2dd4-c36c-4f64-8ae2-5a9ec9b4296b
Sec. 49-730. - Space requirement for non-handicapped plumbing fixtures.
The following minimum clearances apply: (a) Water closets. (1) 15 inches from the center of the fixture to any wall, partition or vanity. (See Figure 49-730(a)(1).) (2) 30 inches wide by 21 inches of clearance in front of the fixture. (See Figure 49-730(a)(2).) (3) 31 inches from the center of one water closet to the center of any other water closet or urinal. (See Figure 49-730(a)(3).) (4) There shall be a minimum of four inches between a water closet and a lavatory. (See Figure 49-730(a)(4).) (5) Except for the grab bar required for disability access, there shall be a minimum of 12 inches clear space above the tank or flush valve of the water closet. (b) Urinals. (1) There shall be a minimum of 15 inches from the center of the urinal to any wall or partition. In no case shall there be less than four inches from the wall or partition and the side of the urinal as measured from the widest point of the urinal. (See Figure 49-730(b)(1).) (2) There shall be a minimum of 31 inches from the center of one urinal to the center of any other urinal or water closet. (See Figure 49-730(b)(2).) (3) There shall be a minimum of 30 inches wide by 21 inches clearance in front of any wall or floor urinal and 30 inches wide by 21 inches clearance in front of pedestal urinals. (See Figure 49-730(b)(3).) (4) There shall be a partition between any urinal and lavatory. (5) The maximum height of a wall mounted urinal shall be 24 inches from finish floor to the rim of the urinal. (c) Lavatories. (1) There shall be a minimum four inches from the side or outer edge of each lavatory to any wall or partition. (See Figure 49-730(c)(1).) (2) There shall be a minimum four inches from the side or outer edge of each lavatory to any other lavatory, water closet or tub. (3) There shall be a clear floor space of 30 inches wide by 21 inches in front of each lavatory. (See Figure 49-730(c)(3).) (d) Showers. (1) The minimum inside measurements shall be 30 inches by 30 inches. (See Figure 49-730(d)(1).) (2) There shall a clear floor space of 24 inches by 24 inches in front of the opening. (See Figure 49-730(d)(1).) (e) Tub. (1) There shall be a minimum clear floor space of 21 inches by 21 inches for entering or exiting of the tub. (See Figure 49-730(e)(1).)
(Ord. No. 40524, § 1, 10-20-15; Ord. No. 42654, § 25, 8-13-21)
Ask a question about Omaha law
Corpus searches the Omaha sections it holds and shows the ones that match, with their citations. Free, no sign-in.