217-13. Swinging Doors.

1. APPLICABILITY. T his section applies to all interior doors between dwel ling units and multiple access tenant corridors and to all exterior swinging doors accessible to grade by stairs or permanently fixed ladders or within 10 feet of grade, except: Screen and storm doors which do a. not provide the primary closure for the doorway opening. b. Doors from the exterior into a vestibul e where a door meeting the requirements of this subchapter separates the vestibule from the building interior. c. Exit doors which are monitored on a 24-hour basis for security purposes by a security guard stationed at the door or at a television monitor where the lock is protected from being shimmied or is a deadlatch or an electronically controlled latch. Exit doors which are electronically d. controlled from the dwelling units and where the entrance doors and dwelling units are connected by voice or signal communications. Common exit doors to hallways e. which are less than 25 feet in length and which do not connect with any other unsecured hallway or unsecured basement. 2. DOORS. All doors covered by this section shal l be maintained in good condition. 3. HINGES. All doors covered by this section which have hinge pins on the exterior side of the building or dwelling uni t shall have nonremovable hinge pins, or the pins or hi nges shall be modified to prevent removal of the door without the use of special tools or equipment. 4. LOCKS. a. All doors covered by this section shall have a cylinder lock in addition to a latching device. The lock shall be either a deadbolt type, either surface-mounted or mortised into the door, with a minimum 1/2 inch bolt, or a surface-mounted vertical bolt lock. The lock cylinders shall be flush-mounted on the exteri or or be protected by a cylinder guard plate or be tapered or rotated to prevent wrenching. Locks shall be openable with the use of a key from the exterior side of the door. In dwelling uni ts which have b. more than one exterior access door, all exterior access doors shall be equipped with a l ock meeting the requirements of this section. c. All common exit doors covered by this section shall be provided with a pry-resistant or tamper-resistant locking device with a minimum 1/2" throw or be protected by a tamper-resistant plate. d. All doors to dwelling units shall be protected by a deadbolt lock with a minimum 1/2" bolt. In dwelling units with more than one i nterior door between the dwelling unit and the public hallway or more than one exterior exi t door, only one door shall be required to be equipped with a lock which is openable with a key from the exterior side of the door. FRAMES AND STRIKES. a. All 5. strikes for surface-mounted locks covered by this section shall be attached to 2 sides of the frame and shall be installed with screws through the face of the jamb perpendicular to the door in a closed position. All strikes in wood frames for b. deadbolts i nside of or mortised into doors covered by this section shall be attached to the frame with at least 2 screws. c. All door frames for doors covered by this section shall be constructed of hardwood, pressed wood, softwood or steel and be maintained in good condition.

Ask a question about Milwaukee law

Corpus searches the Milwaukee sections it holds and shows the ones that match, with their citations. Free, no sign-in.