Sec. 6-32. - Standards for streams without established base flood elevation and/or floodways.
When base flood elevation data and floodway data are not available in accordance with section 6-11, in special flood hazard areas and Community Flood Hazard Areas without base flood elevation data, new construction and substantial improvements shall be elevated or floodproofed to elevations established by the community. The following provisions apply in addition to the standards of section 6-30 and 6-31(4) shall apply: (1) When base flood elevation data or floodway data have not been provided in accordance with section 6-11, then the local administrator shall obtain, review, and reasonably utilize any base flood elevation and floodway data available from a federal, state, or other source, in order to administer the provisions of chapter 5. If data is not available from outside sources, then the following subsections (2-9) shall apply. (2) In special flood hazard areas with base flood elevations (zones AE and A1—30) but without floodways, no encroachments, including fill material or structures, shall be permitted unless certification by a registered professional engineer is provided demonstrating that the cumulative effect of the proposed development, when combined with all other existing and anticipated development, will not increase the water surface elevation of the base flood more than one (1) foot at any point within the community. The engineering certification should be supported by technical data that conforms to standard hydraulic engineering principles. (3) No encroachments, including fill material or other development, shall be located within a distance of the stream bank equal to five (5) times the width of the stream at the top of the bank or twenty (20) feet each side from the top of the bank, whichever is greater, unless certification by a registered professional engineer is provided demonstrating that such encroachment shall not result in any increase in flood levels during the occurrence of the base flood discharge. The enclosure standards of section 6-31(4) shall apply. (4) When base flood elevation data or floodway data are not available in accordance with section 6-22(4)i., in special flood hazard areas and community flood hazard areas without base flood elevation data, new construction and substantial improvements of existing structures shall have the lowest floor of the lowest enclosed area (including basement) elevated no less than forty-two (42) inches above the highest adjacent grade at the building site. (5) Require that all new subdivision proposals and other proposed developments (including proposals for manufactured home parks and subdivisions), include within such proposals base flood elevation data; (6) The floodplain administrator shall require that a single lot applicant develop the base flood elevation for the development site, utilizing accepted engineering practices and procedures. Upon review of the submitted data, the administrator may accept or reject the proposed base flood elevation. When such data is accepted, standards of section 6-31 will apply. (7) Fill within the special flood hazard area shall result in no net loss of natural floodplain storage. The volume of loss of floodwater storage due to filling in the special flood hazard area shall be offset by providing an equal volume of flood storage by excavation or other compensatory measures at or adjacent to the development site. (8) Notify, in riverine situations, adjacent communities and the state coordinating office prior to any alteration or relocation of a watercourse, and submit copies of such notifications to FEMA. Assure that the flood carrying capacity within the altered or relocated portion of any watercourse is maintained. (9) Require all manufactured homes be placed or installed using methods and practices which minimize flood damage. Manufactured homes must be elevated and anchored to resist floatation, collapse, or lateral movement. Dry stacked blocks (stacked without the use of mortar or cement to bond them together) are not allowed within the special flood hazard area.
(Ord. of 3-4-03; Res. of 4-15-14(1), eff. 5-5-14)
Ask a question about Southaven law
Corpus searches the Southaven sections it holds and shows the ones that match, with their citations. Free, no sign-in.