§ 9.8.11 — Manufactured homes

Code of Ordinances, City of Cape Coral, Florida (Supp. No. 39, Update 1; codified through Ordinance No. 45-26, enacted September 3, 2026) · Cape Coral Land Development Code § 9.8.11

Corpus is an independent public-information project, not the official City of Cape Coral website. Stable reference: corpuslaw.us/code/8ff710cf-bc9b-48a6-862c-c77d46adc25e

Section 9.8.11. - Manufactured homes.

A. General. All manufactured homes installed in flood hazard areas shall be installed by an installer that is licensed pursuant to F.S. § 320.8249, and shall comply with the requirements of Chapter 15C-1, F.A.C. and the requirements of this Article. If located seaward of the coastal construction control line, all manufactured homes shall comply with the more restrictive of the applicable requirements. B. Foundations. All new manufactured homes and replacement manufactured homes installed in flood hazard areas shall be installed on permanent, reinforced foundations that: 1. In flood hazard areas (Zone A) other than coastal high hazard areas, are designed in accordance with the foundation requirements of the Florida Building Code, Residential Section R322.2 and this Article; and 2. In coastal high hazard areas (Zone V), are designed in accordance with the foundation requirements of the Florida Building Code, Residential Section R322.3 and this Article. C. Anchoring. All new manufactured homes and replacement manufactured homes shall be installed using methods and practices which minimize flood damage and shall be securely anchored to an adequately anchored foundation system to resist flotation, collapse, or lateral movement. Methods of anchoring include use of over-the-top or frame ties to ground anchors. This anchoring requirement is in addition to applicable state and local anchoring requirements for wind resistance. D. Elevation. All manufactured homes that are placed, replaced, or substantially improved in flood hazard areas shall be elevated such that the bottom of the frame is at or above the elevation required, as applicable to the flood hazard area, in the Florida Building Code, Residential Section R322.2 (Zone A) or Section R322.3 (Zone V and Coastal A Zone). E. Enclosures. Enclosed areas below elevated manufactured homes shall comply with the requirements of the Florida Building Code, Residential Section R322 for such enclosed areas, as applicable to the flood hazard area. F. Utility equipment. Utility equipment that serves manufactured homes, including electric, heating, ventilation, plumbing, air conditioning equipment, and other service facilities shall comply with the requirements of the Florida Building Code, Residential Section R322, as applicable to the flood hazard area.

(Ord. 38-21, § 6, 6-2-2021)

Ask a question about Cape Coral law

Corpus searches the Cape Coral sections it holds and shows the ones that match, with their citations. Free, no sign-in.