Sec. 18-255. - Tables.

The following standards shall be applicable as provided in this division: TABLE A. WALL AND OPENING PROTECTION OF OCCUPANCIES BASED ON LOCATION ON PROPERTY Group | Division | Automatic Fire Protection Required | Fire Resistance of Exterior Walls | Openings in Exterior Walls A | 1 2 | Yes | 2 hours less than 10' 1 hour elsewhere | Not permitted less than 5' Protected 5' to 10' 3 | Yes | 2 hours less than 5' 1 hour 5' to 10' | Not permitted less than 5' Protected 5' to 10' No | 2 hours less than 20' 1 hour elsewhere | Not permitted less than 5' Protected 5' to 20' 4, 5 | Yes | 1 hour less than 10' | Protected less than 20' No | 2 hours less than 20' 1 hour elsewhere | Protected less than 20' E | Yes | 2 hours less than 5' 1 hour 5' to 10' | Not permitted less than 5' Protected 5' to 10' No | 2 hours less than 20' 1 hour elsewhere | Not permitted less than 5' Protected less than 20' I | 4 | No | 2 hours less than 20' 1 hour elsewhere | Not permitted less than 3' Protected 3' to 20' 2 | Yes | 2 hours less than 5' 1 hour elsewhere | Not permitted less than 5' Protected 5' to 20' No | 2 hours less than 5' 1 hour elsewhere | Not permitted less than 5' Protected 5' to 20' 1 | Yes | 1 hour | Not permitted less than 3' Protected 3' to 10' 3 | Yes | Not permitted | Not permitted No | Not permitted | Not permitted H | 1—5 | — | Not permitted | Not permitted F, S | 1, 2 | Yes | 1 hour less than 20' | Not permitted less than 5' Protected 5' to 10' M, B | No | 2 hours less than 20' 1 hour elsewhere | Not permitted less than 5' Protected 5' to 20' R | 1, 2 | Yes | 1 hour less than 5' | Not permitted less than 3' Protected 3' to 5' No | 2 hours less than 20' 1 hour elsewhere | Not permitted less than 3' Protected 3' to 20' 3, 4 | Yes | 1 hour less than 3' | Not permitted less than 3' No | 2 hours less than 20' 1 hour elsewhere | Not permitted less than 3' Protected 3' to 20' U | Yes | 1 hour less than 3' | Not permitted less than 3' No | 2 hours less than 20' 1 hour elsewhere | Not permitted less than 3' Protected 3' to 20' TABLE C. ALLOWABLE FLOOR AREAS Occupancy | Type of Construction I | II A | B | A | B A-1, 2, 3 | 100,000 sf (9,290 m 2 ) | 40,000 sf (3,716 m 2 ) | 10,000 sf (929 m 2 ) | 3,000 sf (279 m 2 ) A-4, 5 | 150,000 sf (13,935 m 2 ) | 50,000 sf (4,645 m 2 ) | 15,000 sf (1,394 m 2 ) | 5,000 sf (465 m 2 ) E, I-4 | 200,000 sf (18,580 m 2 ) | 75,000 sf (6,968 m 2 ) | 20,000 sf (1,858 m 2 ) | 7,500 sf (697 m 2 ) I-1, 2 | 80,000 sf (7,432 m 2 ) | 30,000 sf (2,787 m 2 ) | 8,000 sf (743 m 2 ) | Not permitted I-3 | 40,000 sf (3,716 m 2 ) | 15,000 sf (1,394 m 2 ) | 4,000 sf (372 m 2 ) | Not permitted H-1, 2, 3, 4, 5 | Not permitted | Not permitted | Not permitted | Not permitted F-1, 2, S-1, B | 150,000 sf (13,935 m 2 ) | 50,000 sf (4,645 m 2 ) | 15,000 sf (1,394 m 2 ) | 5,000 sf (465 m 2 ) S-2 | 300,000 sf (27,870 m 2 ) | 100,000 sf (9,290 m 2 ) | 25,000 sf (2,323 m 2 ) | 10,000 sf (929 m 2 ) R-1, 2 | 150,000 sf (13,935 m 2 ) | 50,000 sf (4,645 m 2 ) | 15,000 sf (1,394 m 2 ) | 5,000 sf (465 m 2 ) R-3, 4 | 10,000 sf (929 m 2 ) | 5,000 sf (465 m 2 ) | 3,000 sf (279 m 2 ) | 2,000 sf (186 m 2 ) U | 3,000 sf (279 m 2 ) | 3,000 sf (279 m 2 ) | 1,000 sf (93 m 2 ) | 1,000 sf (93 m 2 ) Occupancy | Type of Construction III | IV | V A | B | H.T. | A | B A-1, 2, 3 | 20,000 sf (1,858 m 2 ) | 6,000 sf (557 m 2 ) | 20,000 sf (1,858 m 2 ) | 4,000 sf (372 m 2 ) | Not permitted A-4, 5 | 30,000 sf (2,787 m 2 ) | 10,000 sf (929 m 2 ) | 30,000 sf (2,787 m 2 ) | 5,000 sf (465 m 2 ) | 1,500 sf (139 m 2 ) E, I-4 | 40,000 sf (3,716 m 2 ) | 15,000 sf (1,394 m 2 ) | 40,000 sf (3,716 m 2 ) | 7,500 sf (697 m 2 ) | 2,000 sf (186 m 2 ) I)1-2 | 15,000 sf (1,394 m 2 ) | 5,000 sf (465 m 2 ) | 15,000 sf (1,394 m 2 ) | 4,000 sf (372 m 2 ) | Not permitted I)3 | 8,000 sf (743 m 2 ) | 3,000 sf (279 m 2 ) | 8,000 sf (743 m 2 ) | 2,000 sf (186 m 2 ) | Not permitted H-1, 2, 3, 4, 5 | Not permitted | Not permitted | Not permitted | Not permitted | Not permitted F-1, 2, S-1, 3B | 30,000 sf (2,787 m 2 ) | 10,000 sf (929 m 2 ) | 30,000 sf (2,787 m 2 ) | 5,000 sf (465 m 2 ) | 1,500 sf (139 m 2 ) S-2 | 50,000 sf (4,645 m 2 ) | 20,000 sf (1,858 m 2 ) | 50,000 sf (4,645 m 2 ) | 10,000 sf (929 m 2 ) | 2,000 sf (186 m 2 ) R-1, 2 | 30,000 sf (2,787 m 2 ) | 10,000 sf (929 m 2 ) | 30,000 sf (2,787 m 2 ) | 5,000 sf (465 m 2 ) | 1,000 sf (93 m 2 ) R-3, 4 | 3,000 sf (279 m 2 ) | 2,000 sf (186 m 2 ) | 3,000 sf (279 m 2 ) | 2,000 sf (186 m 2 ) | 1,000 sf (93 m 2 ) U | 1,000 sf (93 m 2 ) | 1,000 sf (93 m 2 ) | 1,000 sf (93 m 2 ) | 1,000 sf (93 m 2 ) | 1,000 sf (93 m 2 ) For definition of type of construction, see the International Building Code.

(Ord. No. 200418, § 1, 6-18-20)

Ask a question about Kansas City law

Corpus searches the Kansas City sections it holds and shows the ones that match, with their citations. Free, no sign-in.