For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 11-30-4 — FENCES AND FREESTANDING WALLS

Mesa City Code (Supp. No. 22: codified through Ordinance No. 5996, adopted March 9, 2026) · Mesa City Code § 11-30-4

Corpus is an independent public-information project, not the official City of Mesa website. Stable reference: corpuslaw.us/code/9075aba5-c895-4813-adf9-ed7b513bd1a3

11-30-4: - FENCES AND FREESTANDING WALLS

Design Objective: Fences and walls should be an integral design component of the project that identify public areas; direct movement of visitors, define areas intended for private use and allow natural surveillance. Fences, freestanding walls, and similar structures shall comply with the standards of this section. A. AG, RS, RSL, RM, and DR Districts. 1. Maximum Height. a. Front Yards. No opaque or non-transparent fence or freestanding wall within or along the exterior boundary of the required Front Yard shall exceed a height of 3.5 feet. Fences or freestanding walls over 3.5 feet high are allowed in front yards, provided the fence or freestanding wall does not exceed a maximum height of 4.5 feet, and the topmost 1.5 feet is visually transparent and not opaque. b. Side and Rear Yards. No fence or freestanding wall within or along the exterior boundary of the required side or Rear Yards shall exceed a height of 6 feet. 2. Corral Fences. Corral fences are only allowed for the keeping of livestock and similar large animals. Corral fences are permitted in the Agricultural, RS-90 and RS-43 districts subject to conformance with the following standards: a. Materials. Corral fences shall be constructed of masonry, wrought iron, pipe-rail, or similar material, but shall not be of solid construction or made of metal wire, such as chain-link or barbed wire; b. Transparency. Corral fences shall maintain a minimum transparency of 66 percent of the exterior surface of the fence to keep visibility into the property and allow the transfer of light and air; and c. Maximum Height. Corral fences shall not exceed six (6) feet in height. 3. Building Area. When located in the buildable area, the maximum height for fences and freestanding walls is the maximum height allowable in the applicable district. 4. Decorative Features. One entry gateway, trellis, or other entry structure is permitted in the required front or Street-facing Side Yard of each lot, provided the maximum height or width of the structure does not exceed 10 feet in either direction. Such decorative feature shall not have any solid obstruction that exceeds 2 feet in diameter between the height of 3 and 10 feet. 5. DR Districts. Whenever a new multiple residence project is constructed or an existing Single Residence is converted to a multiple residence use, a privacy wall shall be constructed along the property lines separating the multiple residence use, its parking areas and driveways from any existing Single Residence. The privacy wall shall be of masonry construction with stucco, mortar wash or other finish to match that of the main building and shall be 6 feet in height. The privacy wall shall extend along interior side Lot Lines to the front-yard setback of the main building or to the front-yard setback of the existing adjacent residence, whichever is closer to the Street Right-Of-Way, but shall not extend past said setback into the Front Yard without being reduced in height to a maximum of 3.5 feet. 6. Materials. a. Acceptable Materials. Walls and fences shall be constructed of high-quality, durable materials such as stucco finish, masonry or concrete block, brick, decorative cap block, wrought iron, or other similar high-quality material. b. Prohibited Materials. The use of chain-link, barbed wire, razor wire, embedded glass shards, ultra barrier, electrified and other hazardous fencing is prohibited, except for the use of barbed wire fencing used for livestock enclosures. [image omitted; see the official code] FIGURE 11-30-4.A: FENCES B. All Other Zoning Districts. 1. Maximum Height. a. Front Yards and Required Street Side Yards. No fence or freestanding wall within or along the exterior boundary of the required Front Yard shall exceed a height of 3.5-feet. b. Rear Yards and Interior Side Yards. No fence or freestanding wall within or along the exterior boundary of the required interior side or Rear Yards shall exceed a height of 8-feet. c. Building Area. When located in the buildable area, the maximum height for fences and freestanding walls is the maximum height allowable in the applicable district. 2. Fence Materials in Commercial and Employment Districts. a. Materials. Walls and fences shall be constructed of high-quality materials, such as tinted, textured blocks; brick; stone; or ornamental metal; and shall complement the design of an overall development and its surroundings. i. Chain link may only be used when not visible from public view. ii. Wood fencing is not allowed, except wood may be used in conjunction with metal frames for gates used in conjunction with required Screening walls. iii. The use of barbed wire, razor wire, embedded glass shards, ultra barrier, electrified and other hazardous fencing is prohibited in Street-facing yards or where adjacent to any public Right-of-Way. C. Visibility at Intersections. Notwithstanding any other provisions of this Section, fences and walls shall comply with the standards of Section 11-30-14, Visibility at Intersections. [image omitted; see the official code] FIGURE 11-30-4.D CORNER LOT ABUTTING A KEY LOT D. Corner Lots Abutting a Key Lot. In the event the rear property line of a Corner Lot abuts a side property line of an adjoining Key Lot, a 10-foot deep by 10-foot wide visibility triangle shall be maintained over the Corner Lot, starting at the intersection of the rear and Street side property lines of the Corner Lot. See diagram above, 11-30-4D. E. Fence and Wall Articulation. The maximum length of continuous, unbroken, and uninterrupted fence or wall plane adjacent to right-of-way or private streets functioning as public roads shall be 150 feet. Articulation shall be provided through the use of columns, posts, varied height, protrusions and recesses in the horizontal plane. 1. Post and columns shall protrude a minimum of six (6) inches from the adjacent plane. 2. Protrusions and recesses in the horizontal plane, and variations in height shall be a minimum 18 inches.

(Ord. No. 5544, §§ 6—8, 12-9-19; Ord. No. 5996, § 4, 3-9-26)

Ask a question about Mesa law

Corpus searches the Mesa sections it holds and shows the ones that match, with their citations. Free, no sign-in.