§ 33.120.220 — Setbacks
Portland City Code (non-zoning titles; Title 33 separately); partial · Portland Zoning Code § 33.120.220
Corpus is an independent public-information project, not the official City of Portland website. Stable reference: corpuslaw.us/code/90b454b4-a621-4516-bee1-a36e622e565b
33.120.220 Setbacks
A. Purpose. The building setback regulations serve several purposes: • They maintain light, air, separation for fire protection, and access for fire fighting; • They reflect the general building scale and placement of multi-dwelling development in the City's neighborhoods; • They promote a reasonable physical relationship between residences; • They promote options for privacy for building residents and neighboring properties; • They provide adequate flexibility to site a building so that it may be compatible with the neighborhood, fit the topography of the site, allow for required outdoor areas, and allow for architectural diversity; • Setback requirements along transit streets create an environment that is inviting to pedestrians and transit users; • They provide room for a car to park in front of a garage door without overhanging the street or sidewalk, and they enhance driver visibility when backing onto the street; and • The Eastern Pattern Area special setback supports preservation of the area’s characteristics, including large rear yards and tree groves, and supports improved connectivity by leaving space for future connections through the area’s large blocks. B. Minimum building setbacks. The required minimum building setbacks apply to all buildings and structures on the site except as specified in this section. Setbacks for parking areas are in Chapter 33.266. 1. Generally. The required minimum building setbacks, if any, are stated in Table 120-4. In the RM3 and RM4 zones, the minimum side and rear building setbacks apply as follows: a. Buildings that are up to 55 feet tall. The required minimum side and rear building setback for buildings that are up to 55 feet tall is 5 feet. Minor projections allowed by Paragraph 33.120.215.C do not count toward this height measurement; and b. Buildings more than 55 feet tall. The required minimum side and rear building setback for buildings that are more than 55 feet tall is 10 feet from a side or rear lot line that is not a street lot line, and 5 feet from a side or rear lot line that is a street lot line. 2. Eastern Pattern Area minimum rear building setback. a. Minimum rear building setback. In the RM1, RM2, RM3 and RM4 zones in the Eastern Pattern Area the required minimum rear building setback is an amount equal to 25 percent of the total depth of the site. No more than 50 percent of the Eastern Pattern Area rear setback can be vehicle area. The Eastern Pattern Area is shown on Map 120-3. b. Exemptions. The following are exempt from the Eastern Pattern Area minimum rear building setback. When a site is exempt from the Eastern Pattern Area minimum rear building setback, the base zone required minimum rear building setback stated in Table 120-4 applies: (1) Corner lots and lots that are up to 100 feet deep are exempt from the Eastern Pattern Area minimum rear building setback; and (2) Sites where at least 10 percent of the total site area is outdoor common area, including outdoor common area on a roof, and the common areas measure at least 30 feet in all directions are exempt from the Eastern Pattern Area minimum rear setback. (3) Cottage clusters allowed under section 33.120.270.G. 3. Exceptions to the required building setbacks. a. Setback matching. The minimum front and side street building setbacks and the setback of decks, balconies, and porches may be reduced to match the setback on an abutting lot. b. Raised ground floor. In the RM2 and RM3 zones the minimum front building setback may be reduced to 5 feet, and in the RM4 zone the minimum front and side street building setbacks may be reduced to zero feet, for buildings where the finished floor of ground floor residential units is between 2 feet and 5 feet above the grade of the closest adjoining sidewalk. This exception does not apply in the Eastern Pattern Area shown on Map 120-3. c. Courtyard. Except in the Eastern Pattern Area shown on Map 120-3, the required minimum front or side street setback may be reduced to zero in the RM2 and RM3 zones, and may be reduced to 5 feet in the RM1 zone when: (1) At least 20 feet or 25 percent of the length of the street-facing building facade, whichever is greater, is setback at least 40 feet from the street lot line; (2) At least half of the area between the setback portion of the building and the street lot line is landscaped to at least the L1 standard and the setback includes no vehicle area; and (3) The finished floor of the ground floor is between 2 feet and 5 feet above the grade of the closest abutting sidewalk. d. Ground floor commercial. The required minimum front or side street setbacks may be reduced to zero in the RM2, RM3 and RM4 zones when the ground floor includes a commercial use and at least 50 percent of the length of the ground- floor street-facing façade is in a commercial use or is an indoor common area, such as an indoor recreation facility or community room. This exception does not apply in the Eastern Pattern Area shown on Map 120-3. e. Environmental zone. The required minimum front and street building setback and garage entrance setback may be reduced to zero where any portion of the site is in an environmental overlay zone. Where a side lot line is also a street lot line the side building and garage entrance setback may be reduced to zero. All other provisions of this Title apply to the building and garage entrance. f. Split zoning. No setbacks are required from an internal lot line that is also a zoning line on sites with split zoning. g. Alley. No side or rear building setback is required from a lot line abutting an alley. h. Land divisions with existing development. When a dedication of public right-of- way along the frontage of an existing street is required as part of a land division, the minimum front or side setback between an existing building and a lot line that abuts the right-of-way may be reduced to zero. Eaves on an existing building may extend one foot into the reduced setback, except that they may not extend into the right-of-way. Future additions or development must meet required minimum setbacks. i. Eastern Pattern Area. In the Eastern Pattern Area, the footprint of buildings containing only indoor common area, such as recreational facilities or tenant community rooms, may cover up to 25 percent of the Eastern Pattern Area minimum rear building setback. In this case, the building must be set back at least 5 feet from the rear lot line. j. Inner Pattern Area. In the RM2, RM3, and RM4 zones in the Inner Pattern Area, on sites that abut a Civic or Neighborhood Corridor shown on Map 120-1, no setback is required from a lot line that abuts a property that also has a lot line on a Civic or Neighborhood Corridor. See Figure 120-3. However, windows in the walls of dwelling units must be setback a minimum of 5 feet from a lot line that abuts another property and this setback area must be a minimum width of 12 feet or the width of the residential window, whichever is greater. Figure 120-3



C. Maximum building setbacks. 1. Maximum building setbacks on a transit street or in a Pedestrian District. The required maximum building setbacks, if any, are stated in Table 120-4, and apply only to buildings that are enclosed on all sides. The maximum building setbacks on a transit street or in a Pedestrian District are as follows. At least 50 percent of the length of the ground level street-facing façade of the building must meet the maximum building setback standard: a. Applying the standard. (1) Where an existing building is being altered, the standards apply to the ground level, street-facing facade of the entire building. See Figures 120-4 and 120-5. (2) Where there is more than one building on the site, the standards of this paragraph apply to the combined ground level, street-facing facades of all the buildings. See Figures 120-6 and 120-7. (3) For buildings where all of the floor area is in residential use, the street- facing facade of an open porch that meets the following standards is included as part of the ground level, street-facing facade of the building: • For houses, attached houses, manufactured homes and duplexes, the porch must be at least 25 square feet in area. For multi-dwelling structures, the porch must be at least 9 feet wide and 7 feet deep; • The porch must have at least one entrance facing the street; and • The porch must have a roof that is: – No more than 12 feet above the floor of the porch; and – At least 30 percent solid. This standard may be met by having 30 percent of the porch area covered with a solid roof, or by having the entire area covered with a trellis or other open material if no more than 70 percent of the area of the material is open. b. Outside a Pedestrian District. Where the site is not in a Pedestrian District: (1) One transit street. Where the site is adjacent to one transit street, the standard must be met on the transit street frontage; (2) Two non-intersecting transit streets. Where the site is adjacent to two transit streets that do not intersect: • The standard must be met on the frontage of the street with the highest transit classification. If both streets have the same highest classification, the applicant may choose on which street to meet the standard; • If one of the transit streets intersects a City Walkway, the standard must be met along both the street with the highest transit classification and the City Walkway; (3) Two or more intersecting transit streets. Where the site is adjacent to two or more intersecting transit streets, the standard must be met on the frontages of the two streets with the highest transit classifications. If more than two streets have the same highest transit classification, the applicant may choose on which two streets to meet the standard; c. In a Pedestrian District. Where the site is in a Pedestrian District, the maximum building setback standard applies to all street frontages, with the following exceptions: (1) Through lots. If the site is a through lot, the maximum setback standard only applies to the street with the highest transit street classification. If multiple streets have the same highest transit street classification, the applicant may choose on which street to apply the standard. (2) Three or more street frontages. If the site has street lot lines on three or more streets, the maximum setback standard only applies to two of the streets. When this occurs, the standard must be applied to the streets with the highest transit street classifications. If multiple streets have the same highest transit street classification, the applicant may choose on which streets to apply the standard. Figure 120-4 Alteration to Existing Building in Conformance with Maximum Setback Standard


Figure 120-5 Alterations to Existing Building


Figure 120-6 Calculating Maximum Building Setback When More Than One Building On Site


Figure 120-7 New Buildings On Sites With Buildings That Do Not Meet The Maximum Building Setback


2. Exemptions. a. Flag lots. Flag lots are exempt from the maximum setback standards of this section. b. Detached accessory structures. Detached accessory structures are exempt from the maximum setback standards of this section. The street-facing facades of detached accessory structures do not count towards meeting maximum setback standards. See Figure 120-6. D. Extensions into required building setbacks. 1. The following features of a building may extend into a required building setback up to 20 percent of the depth of the setback, except as indicated. However, the feature must be at least 3 feet from a lot line, except as allowed in 33.120.270, Alternative Development Options: a. Chimneys, fireplace inserts and vents, mechanical equipment, and fire escapes; b. Wheelchair ramps, water collection cisterns and stormwater planters that do not meet the standards of Paragraph D.4; c. Decks, stairways, and uncovered balconies that do not meet the standard for Paragraph D.4, but only along a street lot line; and d. Bays and bay windows but only along a street lot line and must meet the following requirements: (1) Each bay and bay window may be up to 12 feet long, but the total area of all bays and bay windows on a building facade cannot be more than 30 percent of the area of the facade; (2) At least 30 percent of the area of the bay which faces the property line requiring the setback must be glazing or glass block; and (3) Bays and bay windows must cantilever beyond the foundation of the building. 2. Building eaves may project up to 2 feet into a required setback, provided the eave is at least 3 feet from a lot line. 3. Canopies and awnings may extend up to 5 feet into a required setback along a street lot line. 4. The following minor features may extend into entire required building setbacks: a. Utility connections attached to the building that are required to provide services, such as water electricity and other similar utility services; b. Gutters and downspouts that drain stormwater off a roof of the structure; c. Stormwater planters that are no more than 2-1/2 feet above the ground; d. Water collection cisterns that are 6 feet or less in height; e. Attached decks, stairs, and ramps that are no more than 2-1/2 feet above the ground. However, stairways and wheelchair ramps that lead to one entrance on the street-facing facade of a building are allowed to extend into the required street setbacks regardless of height above ground; and f. On lots that slope down from the street, vehicular or pedestrian entry bridges that are no more than 2-1/2 feet above the average sidewalk elevation. 5. Detached accessory structures. The setback standards for detached accessory structures including detached mechanical equipment are stated in 33.120.280 below. Fences are addressed in 33.120.285, below. Detached accessory dwelling units are addressed in Chapter 33.205. E. Garage entrance and structured parking setback. 1. Garage entrance setback. The garage entrance setback is stated in Table 120-4. See Chapter 33.910, Definitions, for a description. The walls of the garage structure are subject to 33.120.283 and the applicable front, side, or rear building setbacks. a. In the RM2, RM3, RM4, and RX zone, the garage entrance must be either 5 feet or closer to the street lot line, or 18 feet or farther from the street lot line. If the garage entrance is located within 5 feet of the front lot line, it may not be closer to the lot line than the facade of the residential portion of the building. b. Exceptions. No setback is required from a lot line abutting an alley. However, the Bureau of Transportation may require the garage entrance to be set back to ensure adequate turning radius into the garage. 2. Setbacks for structured parking. Structured parking that allows exiting in a forward motion is subject to the setback requirements for buildings. Structured parking that does not allow exiting in a forward motion is subject to the garage entrance setback standard stated in Table 120-4.
Ask a question about Portland law
Corpus searches the Portland sections it holds and shows the ones that match, with their citations. Free, no sign-in.
