33.430.140 General Development Standards
The standards below apply to all development in the environmental zones except as follows: • Utilities subject to Section 33.430.150; • Septic systems subject to Section 33.430.155; • Land divisions subject to Section 33.430.160; • Property line adjustment subject to Section 33.430.165; • Resource enhancement projects subject to Section 33.430.170; • Rights-of-way improvements subject to Section 33.430.175; • Stormwater outfalls subject to Section 33.430.180; • Flood and water control facilities subject to Section 33.430.185; • Public recreational trails subject to Section 33.430.190; and • Tree removal in scenic resources zone subject to Section 33.430.195. Standards A through C and G through S apply to new development in the resource area. Standards D through S except L apply to alterations to existing development in the resource area. Only standards E, J, K, N, Q, R, and S apply to new development and alterations to existing development in the transition areas. All of the applicable standards must be met. A. The maximum disturbance area allowed within the resource area on the site is determined by subtracting all portions of the site outside the resource area from the number listed in Table 430-1. Table 430-1 Maximum Disturbance Area Allowed

Note: [1] Subtract the amount of area on the site outside the resource area from the number given in the table. B. The disturbance area is set back at least 5 feet from the resource area of any environmental protection zone; C. The disturbance area must be set back at least: 1. Fifty feet from the edge of any identified wetland; 2. Fifty feet from the top of bank of any identified water body within the Columbia Corridor or any identified water body within a protection zone on lots zoned R10, R20, or RF; 3. Thirty feet from the top of bank of any identified water body within a protection zone on all lots except those zoned R10, R20 or RF; 4. Thirty feet from the top of bank of any identified water body within a conservation zone except those within the Columbia Corridor; and 5. Five feet from the edge of the combined flood hazard area. This standard does not apply within the IH, IG2 and EG2 zones. 6. When reconfiguration of the bank carried out in accordance with subsection 33.430.170.A results in the top of bank shifting landward, the applicant may choose to measure the setback from the original top of bank. When this occurs, a survey of the original top of bank line and the new top of bank line must be submitted for verification and then recorded with the County recorder. In all cases the disturbance area must be set back at least 5 feet from the new top of bank line. D. For alterations to existing development, one of the following must be met: 1. The disturbance area does not exceed the limitations of Table 430-1 and the disturbance area is not expanded into or within five feet of the resource area of an environmental protection zone or within five feet of the combined flood hazard area located outside of the IH, IG2 and EG2 zones; or 2. If the existing disturbance area now exceeds the limitations of Table 430-1, alterations are allowed within the existing disturbance area if the following are met: a. The existing disturbance area may not be expanded; and b. Increases in building coverage and exterior improvement area are allowed if: (1) The increase is located outside of the combined flood hazard area. This standard does not apply within the IH, IG2 and EG2 zones; and (2) A site enhancement option is completed. Applicants must show that an area equivalent in size to at least 50 percent of the area proposed for development will be enhanced following one or more of the options described in Table 430-2. If the proposed development is less than 100 square feet, the minimum enhanced area will be 50 square feet. E. The proposed development is set back at least 5 feet from the resource area of any environmental protection zone; F. The proposed development must be set back at least: 1. Fifty feet from the edge of any identified wetland; 2. Fifty feet from the top of bank of any identified water body within the Columbia Corridor or any identified water body within a protection zone on lots zoned R10, R20, or RF; 3. Thirty feet from the top of bank of any identified water body within a protection zone on lots except lots zoned R10, R20 or RF; 4. Thirty feet from the top of bank of any identified water bodies within a conservation zone except those within the Columbia Corridor; and 5. When reconfiguration of the bank carried out in accordance with subsection 33.430.170.A results in the top of bank shifting landward, the applicant may choose to measure the setback from the original top of bank. When this occurs, a survey of the original top of bank line and the new top of bank line must be submitted for verification and then recorded with the County recorder. In all cases the disturbance area must be set back at least 5 feet from the new top of bank line. G. The proposed buildings must be set back at least 5 feet from the edge of the disturbance area; H. Where the distance between a building and the edge of the disturbance area is less than 10 feet, additional temporary disturbance area is allowed. The edge of the additional temporary disturbance area may extend no more than 10 feet from the building. The temporary disturbance area must be replanted with three different native shrub species at a minimum 1-gallon size or bare root, planted at a density of 3 plants per 10 square feet with the remaining area planted with native groundcover using a minimum of 4-inch pots at a density of 8 plants per 10 square feet; I. Temporary disturbance areas and portions of the resource area where removal of non- native vegetation occurs must be replanted so that the area achieves a 90 percent vegetation cover within one year; J. Tree removal and replacement standards. 1. Removal of native trees is allowed as follows: a. Trees removed must be replaced as shown in Table 430-3. Trees less than 6 inches in diameter do not have to be replaced. b. The combined total diameter of all trees removed may not exceed 225 inches, counting only native trees that are at least 6 inches in diameter; c. In resource areas, the removal of native trees is allowed as follows: (1) Within 10 feet of existing or proposed buildings and structures attached to buildings, such as decks, stairs, and carports; (2) Within 10 feet of proposed driveways or right-of-way improvements; or (3) To create up to 500 square feet of permanent disturbance area for uses such as gardens and play area. 2. Non-native non-nuisance trees may be removed if each tree at least 6 inches in diameter is replaced as shown in Table 430-3; 3. Trees listed on the Nuisance Plants List may be removed, if each tree at least 6 inches in diameter is replaced with one native tree. Table 430-2 Minimum Site Enhancement Options

K. Except when the fee-in-lieu of tree replacement is paid, replacement trees must be at least one-half inch in diameter; shrubs must be in at least a 1-gallon container or the equivalent in ball and burlap. All trees and shrubs must be selected from the Portland Plant List and planted on the site within the environmental zone. Conifers must be replaced with conifers and shrubs must consist of at least two different species; L. Nuisance plants. 1. Remove plants on the Nuisance Plants List in an area on the site that is equal to 50 percent of the size of the proposed permanent disturbance area, or from the entire site, whichever is less. 2. Plant removal must occur outside of the permanent and temporary disturbance areas. 3. Nuisance plant removal entails actions such as the removal of: roots, the above ground portion of the plant, and the seeds of the plant such that existing non- nuisance or newly installed plants are able to grow and survive. The non-nuisance plants are maintained free of nuisance plants. 4. The cleared area must be replanted as follows: a. Seed the entire area of removal with a native grass seed. b. Install seven groundcover plants and two shrubs per 50 square feet. Groundcover plants must be a minimum size of four-inch pots and the shrubs a minimum size of one gallon pots. c. Install one native tree that is at least one-half inch in diameter for every nuisance tree over 6 inches in diameter that is removed. d. Planting native species listed on the Portland Plant List is required. M. All vegetation planted in a resource area is native and listed on the Portland Plant List. Plants listed on the Nuisance Plants List are prohibited; Table 430-3 Tree Replacement in Environmental Overlay Zone

Note: [1] Within the combined flood hazard area located outside of the IH, IG2 and EG2 zones, Option A requires at least 3 native trees to be planted. [2] Option B and Option C are not applicable within the combined flood hazard area except on lots zoned IH, IG2 or EG2. [3] The fee-in-lieu of on-site tree replacement uses the Revegetation Fee described in Option 4 of Table 430-2. One increment is equal to the cost to purchase, plant, and maintain one tree, two shrubs, and 7 groundcover plants for a 50 square foot area. N. Minimum setbacks may be reduced as follows: 1. The minimum front and street building setback and garage entrance setback of the base zone may be reduced to any distance between the base zone minimum and zero. Where a side lot line is also a street lot line the side building and garage entrance setback may be reduced to any distance between the base zone minimum and zero; 2. The minimum detached and connected accessory dwelling unit setback of 33.205.040.C.2 may be reduced to any distance between the minimum and zero; and 3. Parking spaces may be allowed within the first 10 feet from a front lot line, and within a minimum side street setback; O. Maximum front or street setbacks are as follows: 1. The front building or street setback of the base zone is the maximum building setback for primary structures. 2. On a lot with more than one street lot line the maximum setback standard applies to the street lot line that is farthest from the resource area. 3. In zones with no minimum front or street setback, the maximum setback is 10 feet. P. Fences are allowed only within the disturbance area; Q. Parking and truck area buffers: 1. Auto and light truck areas. For commercial, industrial, and multi-dwelling residential uses, parking areas for autos and light trucks include a ten foot perimeter buffer from the resource area. The buffer is landscaped with plants listed on the Portland Plant List to at least the L2 standard, as stated in Chapter 33.248, Landscaping and Screening; 2. Medium and heavy truck areas. Where allowed by the base zone, the parking, loading, and maneuvering areas for medium and heavy trucks include a ten foot perimeter buffer from the resource area. The buffer is landscaped with plants listed on the Portland Plant List to at least the L3 standard, as stated in Chapter 33.248, Landscaping and Screening; R. Exterior lights must be spaced at least 25 feet apart. Incandescent lights exceeding 200 watts (or other light types exceeding the brightness of a 200-watt incandescent light) must be placed so they do not shine directly into resource areas; and S. Exterior storage and display areas include a ten-foot perimeter buffer from the resource area. The buffer is landscaped to at least the L3 standard, as stated in Chapter 33.248, Landscaping and Screening.