§ 9-13-65 — IGCC GREEN CONSTRUCTION CODE AMENDMENT, SECTION 1001.3.1.9 (10.3.1.9), SOIL-GAS CONTROL
City Code of Boise City, Idaho (2026 S-32: current through Ord. 38-26, passed 9-29-2026) · Boise City Code § 9-13-65
Corpus is an independent public-information project, not the official City of Boise City website. Stable reference: corpuslaw.us/code/91349558-cb5b-4656-8b96-dd2ba51a7598
9-13-65: IGCC GREEN CONSTRUCTION CODE AMENDMENT, SECTION 1001.3.1.9 (10.3.1.9), SOIL-GAS CONTROL:
1001.3.1.9 (10.3.1.9) Soil-Gas Control. In known areas, per the Idaho Department of Health and Welfare, where elevated soil-gas may be present, the building shall be tested, postconstruction, for radon in accordance with ANSI/AARST MALB. The indoor radon concentration shall be below 4.0 pCi/L. Where radon testing indicates that the indoor radon concentration is 4.0 pCi/L or greater, radon mitigation shall be conducted in accordance with ANSI/AARST RMS-LB, and the building shall be retested to verify that the radon concentration is below 4.0 pCi/L. (Ord. 9-23, 3-7-2023)
Ask a question about Boise City law
Corpus searches the Boise City sections it holds and shows the ones that match, with their citations. Free, no sign-in.