15.48.190 - Stairways and steps.

A. Public Shelters. The minimum width of stairways shall be as in the table below: Occupant Load of Shelter | Width of Stairway 10 or less | 30" 10 to 50 | 36" More than 50 | 44" The handrails may extend into the width listed, however, shall not reduce the width by more than nine inches. The rise of every step shall not exceed eight inches and the tread shall not be less than ten (10) inches. There shall be no more than twelve (12) feet vertically between landings. Headroom on the stairway should be not less than six feet six inches measured vertically from the nose of a step. Ramps may be used in lieu of a stairway when practical. B. Private Shelters. The stairways or steps used in private shelters shall be practical for the site and situation of the shelter with respect to other buildings. A ship's ladder or other type devise may be used to gain entry into the shelter, provided it does not create a hazard and can be used quickly and effectively.

(Prior code 13.32.190)