§ 46-4 — Specific amendments
Omaha Municipal Code (Supp. No. 100, Update 2: codified through Ordinance No. 44760, enacted August 4, 2026) · Omaha Municipal Code § 46-4
Corpus is an independent public-information project, not the official City of Omaha website. Stable reference: corpuslaw.us/code/921a2909-a37a-4cec-b271-ee57e4603562
Sec. 46-4. - Specific amendments.
The following amendments are made to the following portions of The International Fire Code, 2024 edition: Section 301.2 - delete "306" and "and 315." Section 307.2 - Add to end of first sentence "or a recreational fire." Section 501.3 Construction Documents - add "private" before fire hydrant and "when required by the fire code official." to the end of the sentence. Section 503.1.1 Buildings and facilities Exception (1) delete "903.1.2 or 903.1.3." Section 503.2.1 Dimensions - Change "20 feet (6096 mm)" to "24 feet (7315.2 mm)." Section 503.2.7 Grade - Delete and insert "The grade of the fire apparatus access road shall be a maximum of 10% unless approved by the fire code official." NEW SECTION 503.2.9 Appendix D may be used as an alternative option. Section 503.3 Marking - Delete and insert "Where required by the code official, signs shall be posted at each fire apparatus access road to identify such roads and prohibit the obstruction thereof. Signs shall read: "Fire Lane - No Parking Anytime - Omaha Municipal Code". All signs shall have a white reflective background with red letters, and shall be maintained in a clean and legible condition at all times. If there is a curb along the fire lane, the curb shall be painted red or yellow." Section 506.1 Where required - Delete and insert "Approved Knox-Box brand key lock boxes shall be installed on all structures or areas that include but are not limited to: 1) Buildings with fire alarm users or sprinkler systems. 2) Buildings with elevators. 3) Buildings or areas that are restricted by way of a security gate or door or have a similar restricted entry. 4) Buildings secured or restricted where gaining immediate access by Omaha Fire Department is imperative. Section 506.1.1 Locks - Insert "Knox-Box brand" after approved. Section 507.5.1 - Change "400 feet (122 m)" to "600 feet (183 m)" and delete both exceptions. Section 507.5.3 (1) - Delete all after types: insert "shall be served by a minimum of a 6 inch main, and shall be approved by the Omaha Planning Department as well as certified by the Metropolitan Utilities District." Section 507.5.6 - Insert "private" between where and fire. Section 610.1 - Insert "and NFPA 96" after 57. Section 901.6.2. Change Section 901.6.2. from, "Records of all systems, inspections, tests, and maintenance required by the referenced standards shall be maintained in the premises for a minimum of three years and shall be copied to the fire code official upon request" to the following, "Records of all systems, inspections, tests, and maintenance required by the referenced standards shall be maintained in the premises for a minimum of three years. All contractors who perform inspection testing and/or maintenance services on life safety systems referenced in chapters 5, 9 and 11 of this code shall electronically submit all compliant and non-compliant reports via a method approved by the fire code official." Section 903.2.12 Change "Section 3307" to "Section 3306." Section 912.4.1 Locking Fire Department Connection Caps - delete and insert "The fire code official authorizes the use of Knox locking caps for fire department connections for water based fire protection systems. Existing systems shall be updated when the five year internal inspection is done on the system. Backflushing of the system shall be performed immediately prior to the installation of the locking caps. All new water based fire protection systems shall have locking caps on installation of the system." Section 1014.8 Clearance. Revise 1 ½" inches (38mm) to be 2 ¼" (57mm). Section 2001.3 Permits - Delete "to operate aircraft refueling vehicles," insert "for" before application. Section 3405.1 Individual Piles - Add new first sentence - "These regulations shall apply to outdoor storage of tires where 50 or more tires are stored." Change "5000 square feet (464.5 M2)" to "2500 square feet (232.3 M2)", and change "50,000 cubic feet (1416 M3)" to "25,000 cubic feet (707.92 M3)." Add - "A maximum of two tire piles may be established on a single site." Section 3405.6 - Delete. NEW SECTION 3405.8 - Add a new section that reads as follows "Bond. As a condition of the issuance or continuation of any permit authorizing the outdoor storage of tires, the applicant or permittee shall file with the city clerk a bond in favor of the city, with good and sufficient surety, in the amount of $20,000. This bond shall be conditioned that the applicant or permittee, as principal, shall faithfully perform all of the requirements imposed upon the outdoor tire storage operation by federal, state, and local law; and shall perform such cleanup, moving, or removal of tires as is required by federal, state, or local law. This section shall apply immediately to all applications or renewal requests submitted after the effective date of this section. Holders of permits as of the effective date of this section shall file the required bond within 90 days of the effective date of this section. Once every two years after the effective date of this section, the city shall inspect all sites licensed under this section. If such an inspection finds that the fair and reasonable cost to lawfully remove and dispose of all tires stored on the site exceeds $20,000, then the amount of the required bond for that site shall be immediately increased to equal that cost. In such case, the license holder shall be so notified, and shall provide the required bond within 30 days. Nothing in this section shall be construed to permit the storage of a volume of tires in excess of that which is otherwise allowed by law." Section 3407.1 - Delete and insert "Where required. A firmly anchored fence or other approved method of security that controls unauthorized access to the storage yard shall surround the storage yard." Section 3407.2 Construction - Change "6 feet (1829 mm)" to "10 feet (2048 mm)." Section 3504.2.1 When required - Change "30 minutes" to "2 hours" and change "extend" to "modify." Section 5001.1 Scope - Add "and NFPA 400" after chapter. Section 5801.1.3 Fireworks - Add exception 5 "The possession, storage, sale, handling and use of "consumer fireworks," as such term is defined by NEB. REV. STAT. section 28-1241, as amended." Appendix C Section C106 - Private Hydrants C106.1 Private hydrants must meet Metropolitan Utilities District specifications. C106.2 Private hydrants shall be maintained by licensed plumbers or Metropolitan Utilities District employees. C106.3 Private hydrants shall be painted to Metropolitan Utilities District specifications. C106.4 Private hydrants supplied by wells or not certified by Metropolitan Utilities District shall be painted red. C106.5 All new or replaced private hydrants shall have a final inspection and be tested by the Omaha Fire Department and Omaha Planning Department C106.6 Private hydrants not certified and maintained by Metropolitan Utilities District shall be inspected annually by a certified plumber and inspection records kept on the premises.
(Ord. No. 40601, § 1, 12-22-15; Ord. No. 42493, § 3, 4-13-21; Ord. No. 44584, § 4, 2-3-26)
Ask a question about Omaha law
Corpus searches the Omaha sections it holds and shows the ones that match, with their citations. Free, no sign-in.