Sec. 29-82. - Sanitary and storm drainage.
(a) The low heel connection on a low-heel ninety (90) shall be used for vent only. The side-outlet on a side-outlet tee shall be used for drainage only, both fittings shall be installed in the vertical position. (b) Building drains and sanitary sewer lines shall be sized by total of fixtures and length of pipe. Drains shall be laid on a bed of bank sand. (c) Tunnel work done underneath the slab of a building shall have clear pictures of all connections, runs of pipe, hangers and cleanouts and shall be left at the jobsite for the inspection. Each photograph shall include the address of the jobsite by either being written legibly on the piping or by signage being clearly visible in the photograph. Backfill materials and methods shall be approved in writing by a licensed engineer and posted with pictures and shall also be left at the jobsite at the time of final inspection. (d) Storm drainage work shall be permitted on a plumbing commercial site work application by a registered plumbing contractor. (e) Storm drains shall be backfilled with a minimum of six (6) inches of stabilized sand over the line. (f) Backwash drains from swimming pools, wading pools, or hot tubs shall drain indirect through a minimum one and one-half-inch pipe into a four-inch-p-trap connected to the sanitary sewer line with an approved air gap. EXCEPTION: P-trap not required if a cartridge filter is utilized on pool equipment. (g) Two-way cleanouts shall be two (2) wyes or combinations arranged to allow complete cleaning in all directions or an city approved double cleanout with two vertical risers. Such clean-outs are required to be installed outdoors at the conjunction of the building drain and building sewer where each sanitary sewer or grease waste main exits a building. (h) Dishwasher drain shall be installed with an air/gap fitting or by running the drain line and securing it to the top of the cabinet then connecting to the disposal or y-tailpiece.
(Ord. No. 17-009, § 1(Exh. A), 1-17-17)
Ask a question about Pasadena law
Corpus searches the Pasadena sections it holds and shows the ones that match, with their citations. Free, no sign-in.