Long Beach Municipal Code § 22.40.010 Tables 40-1 and 40-2 of this chapter establish development standards.
22.40.010 - Tables 40-1 and 40-2 of this chapter establish development standards.
A. Applicability. All development in the MFR districts shall comply with the development standards set forth in Tables 40-1 and 40-2. Refer to Table 40-1 that establishes the maximum intensity standards such as Floor Area Ratio (FAR) and maximum building heights. Refer to Table 40-2 that establishes the development standards that includes setbacks, stepbacks, open space, and storage. Below is an overview of each of the development standards.
B. Site Plan Review. Site Plan Review shall be required for all projects with ten (10) or more units in the MFR zoning districts. This includes both new construction and additions to projects that result in a total of ten (10) or more units on the subject lot.
C. Density. Residential development density is not designated by any single standard but is calculated based on meeting the development standards delineated in Chapter 22.40, including but not limited to building height, setbacks, parking, open space. Density levels correlate to the General Plan in the aggregate and may vary from individual lot to lot.
D. Floor Area Ratio (FAR). The intensity of non-residential uses allowed within MFR zones shall be limited by the maximum FAR established by the General Plan as reflected in Table 40-1.
a. For mixed-use projects the FAR maximum shall only apply to the non-residential gross floor area of the project.
b. Residential gross floor area of the project shall be limited by maximum density and shall be exempt from the FAR limit.
c. FAR calculations shall adhere to the requirement of Section 21.31.235.
E. Building Height. Building height shall be regulated by maximum number of stories and the dimensional height of the structure.
1. Building height shall be measured as the vertical distance between the adjacent sidewalk grade and highest point of the parapet (for flat roofs), or the average height of the highest and lowest ridge point of the top floor roof line (gable, pitch, hip, or other non-flat roof) that does not add to the useable square footage to the building.
2. Measurement of building height shall exclude the following features:
a. Vertical architectural projections (building elements added for architectural interest without adding interior floor area, such as towers and cupolas), not to exceed ten (10) feet above parapet height.
b. Horizontal architectural projections which cantilever five (5) feet or less from the exterior wall (or rooftop feature) shall not be included as part of the exterior wall line.
c. Rooftop guard rails.
d. Permanent unenclosed roof deck features located two (2) feet or more from the exterior wall plane (including shade or partial covering structures, or similar features) up to fifty percent (50%) of the principal building footprint.
e. All mechanical equipment (including solar panels or other alternative energy equipment/infrastructure, elevator and mechanical equipment penthouses, and all associated screening features) up to 12 feet in vertical projection.
f. Subterranean and semi-subterranean parking.
Table 40-1 Development Standards: Intensity
Legend: Acre=ac Feet = ft. Dwelling unit = du Square feet = sf. Maximum= Max Minimum=Min | Zones | Notes and Exceptions:
MFR-L | MFR-M
Density
Maximum non-residential FAR | 0.5 | 0.75
Lot Dimensions
Min Lot Width (ft.) | 25 ft. | 50 ft.
Min Lot Width (corner) (ft.) | 25 ft. | 55 ft.
Height/Stories
Maximum Number of Stories | Consistent with the General Plan; see Citywide District Height Map | Measured from existing grade; subterranean and semi-subterranean parking shall not be counted toward building height. Individual stories cannot exceed 15 feet in height.
(ORD-24-0015 § 1(Exh. A), 2024)