Stack height.
Minneapolis Code of Ordinances § 47.130
in effect47.130. - Stack height.
(a) All newly constructed stacks or chimneys serving one (1) or more nonresidential establishments shall extend at least ten (10) feet above the highest point of any roof within a radius of fifty (50) feet of the chimney. Any existing stack, chimney or vent is required to comply with the minimum requirements of this chapter.
(b) Exemptions. Such chimney height requirements may be waived by the commissioner if:
(1) Special abatement equipment is installed that controls emissions in such a way that those emissions are in compliance with the provisions of this chapter;
(2) The commissioner approves other means that ensure that emissions are in compliance with the provisions of this chapter; or
(3) The commissioner determines that such stack height requirements are not necessary to meet the minimum emissions standards of this chapter. (2008-Or-037, § 23, 5-16-08; 2013-Or-101, § 10, 12-6-13)
Source: City of Minneapolis, Minnesota, Code of Ordinances, City Charter and Park and Recreation Board Code of Ordinances (Municode Library, library.municode.com)URL: https://library.municode.com/mn/minneapolis/codes/code_of_ordinances?nodeId=COOR_TIT3AIPOENPR_CH47ENAIPO_47.130STHEFetched: 11/2/2026