Seepage bed requirements.
Omaha Municipal Code § 49-2173
in effectSec. 49-2173. - Seepage bed requirements.
A seepage bed may be used for the treatment field only when conditions prevent the installation of a conventional lateral system.
(a) A seepage bed is any excavation trench wider than five feet.
(b) Seepage bed construction shall be limited to areas having natural slopes of less than six percent.
(c) If a seepage bed is used, the minimum depth of gravel under perforated drain pipe shall be 12 inches and the minimum fill of gravel over the pipe shall be six inches.
(d) Area requirements for seepage bed shall be at least 25 percent greater than for a conventional lateral system which would service the same installation.
(e) The tile or distribution pipe in beds shall be uniformly spaced no more than five feet apart and no more than 30 inches from the side walls of the beds.
(f) Absorption area for a bed shall be calculated by determining the required square footage for a trench. Multiply the area by the factor in Table 49-2173.
Table 49-2173
Absorption Area Factors
Width of Bed in Feet | Factor
>5 to 10 | 1.25
>10 to 15 | 1.33
>15 to 20 | 1.5
>20 | Unacceptable
(Ord. No. 40524, § 1, 10-20-15)
Source: City of Omaha, Municipal Code and City Charter (Municode Library, library.municode.com)URL: https://library.municode.com/ne/omaha/codes/code_of_ordinances?nodeId=OMMUCOCHGEORVOII_CH49PL_ARTXXIPRSETRSY_DIV4CORE_S49-2173SEBEREFetched: 10/28/2026