Sec. 49-512. - Pipe and valve identification.

Piping and valves installed under this chapter above ground and below ground in all buildings shall be identified in accordance with ANSI A13.11 and this article's requirements. Exception: Single family dwellings and Group R2 of Type V construction. (a) All pipe and valves shall be identified according to the following provisions and Tables 49-512(c) and 49-512(d): (1) Pipe and valves installed above ground in all commercial buildings of two stories or more shall be identified in accordance with ANSI A13.11 and other chapter requirements. (2) Below ground pipe shall be labeled with a two inch wide polyethylene tape for the entire length of the pipe including branches. The tape shall be attached to the top of the pipe with plastic ties around the warning tape and the pipe every five feet on center. (3) Systems transporting hazardous materials shall be identified using durable markers stating the type of material in the system in black letters on a yellow background. Valves shall be tagged in the same manner. (4) Systems transporting nonhazardous materials shall be identified using durable markers stating the type of material in the system in white letters on a green background. Valves shall be tagged in the same manner. (5) In all buildings containing both potable and non-potable water systems, each system shall be identified. (6) Piping, except vent piping, shall be labeled with arrows showing direction of flow. (b) Piping shall be labeled at no more than ten feet on center and at the following locations: (1) Within 12 inches of each joint or coupling. (2) Within 12 inches of each 90 degree or greater change in direction. (3) Within 12 inches of one leg of each tee. (4) All swimming pool pipe and valve above ground in equipment rooms shall be identified at three-foot intervals or between tees. (c) Lettering size shall be determined by the outside diameter of the pipe for non-insulated systems and by the outside diameter of the insulation for insulated systems. See Table 49-512(c) below. Table 49-512(c) The minimum lettering height Outside Diameter (inches) | Lettering Height (inches) ¾ and less | ¾ 1 to 2½ | 1½ 3 and over | 2½ (d) The following Table 49-512(d) lists typical piping systems and the required label colors: Table 49-512(d) System Colors Chemical Waste | Black letters on orange background Chemical Vents | Black letters on orange background Chlorine | Black letters on yellow background Domestic cold water | White letters on green background Domestic hot water | White letters on green background Non-potable water | Black letters on yellow background Recirculating water | White letters on green background Sanitary sewer | White letters on green background Sanitary vent | Black letters on yellow background Storm drain | White letters on green background Swimming pools | White letters on green background Grease lines | White letters on green background Grease vent | White letters on green background Gray water | See note 1 Rainwater harvesting | See note 1 Reclaimed water | See note 1 Note 1: All piping conveying gray water, water from rainwater harvesting system or any reclaimed water shall be purple in color or be painted with a distinctive purple paint. There shall be additional labeling with white letters reading "GRAY WATER NOT FOR HUMAN CONSUMPTION", "RAINWATER, NOT FOR HUMAN CONSUMPTION" or "RECLAIMED WATER, NOT FOR HUMAN CONSUMPTION" at intervals of no more than ten feet on center with a minimum one time per room or space and showing direction of flow. (e) Cleanouts. All cleanouts shall be labeled for easy identification, i.e., sanitary, storm, lab waste, chemical waste, etc., in a manner which would resist wear. Exception: Dwelling units, townhouses and R2 apartments. In the absence of specific requirements, ANSI Standard A13.1 shall be utilized.

(Ord. No. 40524, § 1, 10-20-15)

Ask a question about Omaha law

Corpus searches the Omaha sections it holds and shows the ones that match, with their citations. Free, no sign-in.