For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 152.19 — Roof signs

Code of Ordinances, City of Springfield, Illinois (Supp. No. 82: codified through Ordinance No. 146-04-26, enacted April 7, 2026) · Springfield, Ill., City Code § 152.19

Corpus is an independent public-information project, not the official City of Springfield website. Stable reference: corpuslaw.us/code/970931d6-8b9c-4f1a-9ccd-4b4b8fd3327a

§ 152.19. - Roof signs.

(a) Every roof sign shall be constructed entirely of fire-resistive materials, including the uprights, supports, and braces, except that the ornamental molding, battens, cappings, and nailing strips, platforms, and the decorative trimmings may be constructed of combustible materials. (b) No roof sign shall project beyond the exterior wall. (c) Roof signs shall be so constructed as to leave a clear space, except for the structure supporting the sign, of not less than four feet between the roof and the lowest part of the sign. (d) Roof signs shall be thoroughly secured and anchored to the building over which they are constructed and erected. The dead and wind loads from the signs shall be distributed to the structural elements of the building in a manner that no element shall be overstressed. Roof signs weighing more than 50 pounds, or greater than six feet, zero inches in height, or with a face area greater than 20 square feet shall be designed by a structural engineer, or by an architect, licensed in the State of Illinois. The structural engineer or architect shall design the sign, the sign supports, and shall analyze the capacity of the roof structure to safely support the loads imposed by the sign. (e) Uplift due to overturning of roof signs shall be adequately resisted by proper anchorage to the building walls or structure, or by sufficient concrete counterweights to resist uplift. Proper anchorage to the building walls or structure shall include alterations to the building as may be needed to integrate and adequately interconnect sufficient dead load to equal not less than 50% in excess of the computed uplift applied to the building by the sign. Where uplift is resisted by counterweights, their weight shall exceed the amount of the uplift by 50%. If the counterweights apply loads to the roof that are greater than ten pounds per square foot, the roof structure must be analyzed by a structural engineer, or by an architect, licensed in the State of Illinois.

(Ord. No. 826-12-06, § 1(Exh. A), 12-19-06)

Ask a question about Springfield law

Corpus searches the Springfield sections it holds and shows the ones that match, with their citations. Free, no sign-in.