§ 13.1 — Form-Based Zoning: General Standards
Code of the City of Arlington, Texas (City Secretary chapter PDFs as posted 2026-11-07, each current through the ordinance named on its cover, with the City Secretary's adopted-not-yet-codified Ordinances 25-063, 25-069, 25-073, 25-074, 25-075, 25-084, 26-003, 26-004, 26-019, 26-024 and 26-027 applied; Anti-Discrimination chapter not included) · Arlington City Code, Unified Development Code Chapter, § 13.1
Corpus is an independent public-information project, not the official City of Arlington website. Stable reference: corpuslaw.us/code/9733b9f0-e3e6-4db0-82f9-9f3b0e30e674
Section 13.1 Form-Based Zoning: General Standards
13.1.1. INTRODUCTION A. Background 1. The City of Arlington has identified various locations in the city that could benefit from redevelopment by using form-based zoning (FBZ). FBZ regulates the shape, scale, and character of development rather than focusing on the property’s use and serving an auto-oriented design. 2. Article 13 is organized with a user-friendly structure to navigate and apply the requirements for a development project. Regulations and standards in Article 13 are presented graphically in simple diagrams and photographs as well as supplemental text. These standards are tied to a Regulating Plan associated with all areas zoned FBZ that functions like a zoning map, assigning an appropriate character, form, and scale together with street context. 3. FBZs allow a mix of appropriate land uses chosen to ensure compatibility amongst different contexts, neighborhoods, and the intended area’s character. The standards shape the relationship between building facades and the public realm (i.e., the public and private space between buildings), the form and mass of buildings in relation to one another, and the scale and type of blocks. B. Relationship to the Comprehensive Plan and Small Area Plans Form-based zoning is generally intended where city plans and policies support the vision for walkable, mixed-use redevelopment that relates the city’s investment in the public realm with private realm development. These include areas where some combination of the following exists: 1. Property values are declining and investment in city infrastructure or other major private investment could drive a better form of development; 2. There is significant context to support walkable, mixed-use redevelopment including a compact street grid, range of housing types, potential for neighborhood scale amenities, all aligned with market opportunities; 3. Proximity to regional destinations and roadways and a critical mass of under-developed land ripe for reinvestment; and 4. Location at neighborhood or regional nodes with available infrastructure that can support more intensity and attract new uses, residents, and businesses, alike. C. Title 1. Article 13 sets out the standards for all Form-Based Zoning (FBZ) in the City of Arlington. 2. Section 13.1 contains the Form-Based Zoning: General Standards, hereafter referenced as FBZ-GS that apply to all areas zoned as FBZ in the city. 3. In addition, when a specific area or neighborhood is rezoned under this Article, it shall be known as a Form-Based Zoning District known as FBZD. a. After an area or neighborhood is rezoned, the new, supplemental regulations (FBZD), together with the FBZD Regulating Plan, are added to Article 13 of the UDC and marked with a distinct prefix that identifies the name of the FBZD. For example, the Downtown Form-Based Zoning District and Regulating Plan would be referred to as “DT-FBZD.” b. In instances where the FBZ-GS differs from those created under an FBZDs, the FBZDs standards supersede the FBZ-GS. D. Purpose and Intent The purpose and intent of FBZs in the City of Arlington is to implement walkable, mixed-use development by: 1. Promoting development that aligns the market opportunities with city’s reinvestment in public infrastructure; 2. Balancing predictability of development outcomes with flexibility to address changing market site conditions; 3. Streamlining redevelopment regulations to make it easier to implement walkable, mixed use; 4. Reinforcing streets as public spaces that encourage more walking and cycling; 5. Supporting economic development, sustainable tax base, increased job creation, increased housing supply, and reduced housing costs by allowing a more flexible mix of uses and standards; and 6. Support redevelopment within areas, neighborhoods, and major corridors with more walkable development. E. FBZ Organization & Applicability 1. Organization For all areas zoned FBZD, standards in Section 13.1, Form-Based Zoning: General Standards shall apply in addition to any standards in the FBZDs and Regulating Plan adopted at the time of rezoning of the area or neighborhood. Figure 13.1-1 establishes the framework to structure the sections of Article 13. [Figure: Figure 13.1-1 Form-Based Zoning District Structure] [image omitted; see the official ordinance] 2. Applicability of the UDC Articles: Development in all FBZDs shall be exempt from standards in other Articles of the UDC unless specifically referenced in this Article. a. Property rezoned FBZ under this Article are subject to Section 13.1, Form-Based Zoning: General Standards. b. Supplemental standards in FBZDs established with for each area, may modify or add to 13.1, Form-Based Zoning: General Standards. c. Development standards not addressed in Article 13 are governed by the City of Arlington UDC, unless they conflict with Article 13. In the event of a conflict, Article 13 shall supersede. d. Terms used throughout Article 13 are defined in Section 12.8, “Definitions Related to Form-Based Zoning.” For terms not defined otherwise in Article 12, refer to Webster’s Dictionary. e. Numerical standards and written text take precedence over any conflicting graphics in this Article. F. Existing Planned Development Districts within FBZDs All Planned Development Districts within FBZDs shall remain in effect unless property owners choose to request a rezoning to the corresponding FBZD through the City’s rezoning process outlined in UDC Section 10.4.2. G. Using Article 13 The following shall guide the process used to determine the uses and development standards applicable to property within FBZDs. 1. Step 1: Locate the subject property on the FBZD Regulating Plan Each area/neighborhood will have its own Regulating Plan with a prefix to denote the name of the area (refer to Sections 13.2, 13.3, etc.). 2. Step 2: On the FBZD Regulating Plan, identify the following: a. Base Sub-district or Special District designation b. Frontage designations along all street frontages c. Recommended Future Streets or Vehicular Accessways (if any) d. Recommended/Improved Pedestrian Connections (if any) e. Any other Special Requirements such as Ground Floor Commercial Ready, etc. 3. Step 3: Refer to Article 13.1 Form-Based Zoning: General Standards for standards that are applicable to all FBZDs. Article 13.1 includes standards for the following: a. Use Standards (Section 13.1.4) b. General Standards Applicable to all Sub-Districts (Section 13.1.5) c. Base Sub-district Site and Form Standards (Section 13.1.6) d. Building Design Standards (Section 13.1.7) e. Street and Sidewalk Standards (Section 13.1.8) f. Parking, Screening, and Landscaping (Section 13.1.9) g. Open Space Standards (Section 13.1.10) h. Signage Standards (Section 13.1.11) 4. Step 4: Refer to the corresponding FBZD standards for any supplemental requirements. These standards are intended to address conditions that are unique to the district including the creation of any Special Districts. Example modifications may include: a. Use Standards (modifications to the permitted uses and/or Special District use table) b. Sub-district Form and Site Standards (may include additional Special District standards that are unique to the area, corridor, or neighborhood or different Sub-district height or density standards) c. Building Design standards (may include additional or modified building design standards) d. Streets and Sidewalks (may include street and sidewalk designs that address specific roadways) e. Parking, Screening and Landscaping (may include modifications including parking ratios) f. Signage Standards (may include modified sign standards) 13.1.2. ADMINISTRATION A. Development Review Process All applications for development or redevelopment within FBZDs that meet the standards under Article 13 shall follow the development review procedures established for Zoning Site Plans established under Article 10, Section 10.4.4. Any appeals from the decision of the Zoning Administrator on Zoning Site Plans shall be processed as a Major Modification as established in 13.1.2.B.4. below. B. Modifications to FBZ-GS and FBZDs 1. Purpose a. Specific site features such as steep slopes, flood plain, drainage, lot shape, physical barriers or easements, may create conditions that make compliance with a specific standard impractical or undesirable. It is also recognized that alternative design solutions that are unique to specific projects and sites may achieve the intent of the FBZ but may not comply with a specific requirement. b. This section establishes the procedures for considering requests for a modification to the standards. These are divided into Minor Modifications approved by the Zoning Administrator (see Sec. 13.1.2.B.3) and Major Modifications approved by the City Council (see Sec. 13.1.2.B.4). c. Minor Modifications shall not be used to: (i) Modify the required dimensional standard of a lot beyond the exception below: (1) Exception: Dimensional standards for infill residential lots smaller than one acre may be modified by up to 25 percent. (ii) Authorize a land use that is not permitted in the sub-district; (iii) Modify the density established for a sub-district; d. Any of the General Standards in Section 13.1 may be modified in addition to creating any Special Districts with the adoption of any FBZD Regulating Plans and corresponding standards. e. It is the responsibility of the applicant to meet the burden of clearly demonstrating the reason for the requested modification and to provide sufficient documentation to illustrate how the modification is related to a site constraint or how the modification would equal or exceed the existing standard in terms of achieving the following guiding principles. 2. Guiding Objectives: In addition to the Purpose and Intent of the FBZ-GS (Section 13.1.1.D.) and the FBZDs subsequently adopted, the following principles shall guide all modification applications considered by the Zoning Administrator (Minor Modifications) or the City Council (Major Modifications): a. The physical conditions of the property -- such as steep slopes, flood plain, drainage, lot shape, physical barriers or easements -- may make compliance to the specific standard physically impossible, and this physical or financial hardship is not created by the applicant; b. The modification will not negatively impact adjacent property owners, the character of the area, traffic conditions, parking, public infrastructure, storm water management, and other matters affecting the public health, safety, and general welfare; and c. The modification will not result in a substantial departure from the principle that new development should add value to the neighborhood’s walkability, where links between places are direct, safe, comfortable, and attractive. d. The modification will contribute to many of the following: (i) Encourage creativity, architectural variety, and exceptional design; (ii) Maximize opportunities for adaptive reuse, redevelopment, and new investment; (iii) Require excellence in the design of the public realm; (iv) Increase range of housing options; (v) Promote development that will support mobility and desirable commercial services; (vi) Protect the integrity of historic landmarks; (vii) Increase or protect the tree canopy; (viii) Maximize connectivity and access; (ix) Ensure the provision of amenities that contribute to a safe, livable, and well-balanced urban environment; or (x) Support adopted City Comprehensive Plan policies. 3. Minor Modifications: During the review process, the Zoning Administrator or designee may approve the following Minor Modifications to the FBZ-GS and FBZD standards at the request of an applicant based on the Guiding Objectives above. Minor Modifications shall follow the process established in Section 10.4.24. a. Building Setbacks (i) Along Type ‘A’ or Type ‘B’ Frontages, the maximum front setback may be increased by 10% up to a maximum of 5 feet. However, to facilitate a minimum sidewalk width of 6 feet and ensure a minimum distance from the building façade to the street curb of 15 feet, a larger maximum setback may be granted. (ii) A reduction of up to 2 feet from any required minimum setback is allowable. Notwithstanding this reduction, the distance from any building façade to the curb of a public street must maintain a minimum of 15 feet, accommodating a sidewalk width of no less than 6 feet. b. Frontage Build-out: Decrease of up to 15% of the required Frontage Build-out along a Type ‘A’ and Type ‘B’ Frontages (Note on how Minor Modification allowed is calculated: if the minimum frontage build out is 40%, then the Minor Modification would allow it to be a minimum of 34%). c. Parking Setbacks: Decrease of up to 5 feet of a required parking setback along a Type ‘A’ designated frontage. d. Building Height: Increase of up to 4 feet of the maximum building height to screen any rooftop service equipment. e. Transparency: Decrease of up to 5% of the minimum percentage of windows and doors required along a Type ‘A’ or Type ‘B’ Frontage building facades. f. Landscaping: Where conflicts arise (such as reduced right-of-way or location of utilities), perimeter plantings or other required landscaping abutting a street edge may be substituted for streetscape planting within the public right-of-way. g. Street Network and Blocks: Required new streets and block dimensions may be adjusted administratively with the approval of a Project Circulation Plan that is consistent with the general intent and principles of the FBZDs and Section 13.1.8. Adjustment to existing street networks may require amendments to the city’s adopted Thoroughfare Development Plan and shall also meet the City’s Subdivision Ordinance. h. Street Design and Streetscape: (i) Zoning Administrator may approve minor modifications to streetscape requirements (including placement of street trees, lighting, etc.) caused by utility conflicts, fire hydrants, shallow underground utilities, curb cuts or any other impediments. The sidewalk along all streets shall not be narrower than 6 feet and curb to building face shall be no less than 15 feet. (ii) The Zoning Administrator (based on recommendations from the City Engineer and/or Fire Marshall) may modify any of the street cross sections to accommodate traffic management, utilities, and fire/emergency access as needed. i. Front Facing Garages: Front facing garages in the TN and UN districts may be permitted under the following limited conditions that were not self-created by the property owner: (i) The lot is shallower than normal lots in the block; or (ii) The lot is narrower than 45’ but wider than 30’ with no access to a viable alley due to the mid-block location of the lot. j. Minimum Lot Dimensions: The Zoning Administrator may approve minor modifications (25% or less) to minimum lot dimension requirements due to existing lot configurations, plat constraints, or similar physical limitations for all infill lots that are less than one-acre. Such modifications must not materially alter the allowed density, intended form, scale, or character of development within the FBZ. k. Other Minor Modifications: (i) Other Minor Modifications are enumerated in different sections of Section 13.1 with specific criteria for approval of such modifications. (ii) Modifications to Numerical Standards in Article 13: The Zoning Administrator may approve a modification of no more or less than 15 percent of all other numerical standards (other than those specified above) under the following conditions: (1) A small modification of a numerical standard is needed to accommodate existing conditions and context; and (2) The proposed development still meets the intent of the FBZD. l. In no case can Minor Modifications be used to modify any Type ‘A’ Frontage requirements beyond specifically allowed above for the following elements: frontage build-out, transparency, parking configurations and setbacks, and building design standards. m. Appeals: Appeals of the Zoning Administrator’s decision on Minor Modifications shall be processed as a Major Modification. 4. Major Modifications: The City Council is responsible for reviewing Major Modification requests that do not qualify as Minor Modifications. Major Modifications shall follow the process established in Section 10.4.25. a. When reviewing requests for Major Modifications, the Zoning Administrator and the City Council must consider the guiding principles stated in Section. 13.1.2.B.1 and Section 13.1.2.B.2 and the purpose and intent of the FBZ-GS, FBZDs, and Sub-districts in Article 13. b. Public Notification: All Major Modifications shall follow Section 10.3.6. c. The applicant must meet the burden of presenting an alternative means of compliance that clearly demonstrates how the Major Modification would equal or exceed the existing standard in terms of achieving the guiding principles. 5. Changes to Regulating Plan Elements: Changes to any element contained in the Regulating Plan must be processed as a zoning change subject to standards in Article 10. 13.1.3. FORM-BASED ZONING DISTRICT REGULATING PLANS A. Rezoning Required Each area seeking to adopt Form-Based Zoning must undergo a rezoning process. Process for rezoning must follow the process for zoning change in UDC Article 10. This process involves the formulation of a FBZD Regulating Plan, identified by a unique two-letter or word prefix corresponding to the specific area (example: DT-FBZD for Downtown). An FBZD Regulating Plan should encompass the mandatory elements and optional elements required in this section: 1. Mandatory Elements in an FBZD Regulating Plan: a. Designation of Base Sub-districts (at least two of the base Sub-districts established) b. Frontage Designations (at least two frontage designations) c. Street and Pedestrian Connections d. Open Space Designations 2. Optional Elements in an FBZD Regulating Plan a. Designation of any Special Districts b. Additional Frontage Designations (such as Required Ground Floor Commercial Ready Frontage, etc.) c. Other Special Requirements specific to the FBZD B. Designation of Base Sub-districts Every Regulating Plan is required to clearly outline at least two (2) of the base sub-districts established here. These Sub-districts should reflect the area’s unique vision and character while providing a clear framework to guide development scale, intensity, and land-use compatibility. This framework will ensure that the development is in harmony with the existing and anticipated character of the land uses in the area. 1. Traditional Neighborhood (TN): This Sub-district is intended for existing or new low- to medium-density residential neighborhoods developed with enhanced walkability, including a regular street grid and alleys, range of lot sizes, with proximity to commercial and mixed-use areas. The objective is to create a mixture of housing options adjacent to nonresidential areas. [Figure: Figure 13.1.3-1: Vision for a Traditional Neighborhood street] [image omitted; see the official ordinance] 2. Urban Neighborhood (UN): This Sub-district is intended to be a transition between the Core and Traditional Neighborhood Sub-districts. Urban Neighborhood is also appropriate between high-traffic corridors and established neighborhoods by providing opportunities for medium-density residential, small offices, and retail uses that serve the adjoining neighborhood(s). Development standards in this Sub-district are intended to emphasize scale of development to create appropriate transitions. The height and intensity allowed may vary based on the context and adjacency of the Urban Neighborhood. [Figure: Figure 13.1.3-2: Vision for development along an Urban Neighborhood street] [image omitted; see the official ordinance] 3. Corridor Mixed-Use (CMU): This Sub-district is intended for higher traffic, mature corridors generally characterized by single-use, auto-oriented properties situated between major intersections. The Sub-district’s standards encourage moderate redevelopment as the market evolves. The objective is to emphasize enhancements to pedestrian safety, walkability, and the visual appeal of the sites, including improved cross access and landscaping. [Figure: Figure 13.1.3-3: Vision for development in the Corridor Mixed-Use Sub-district] [image omitted; see the official ordinance] 4. Core (C): This Sub-district is intended to support the broadest range of activities and structures. The vision for this sub-district is to foster a walkable, mixed-use core strategically positioned in Downtown Arlington and other regional nodes close to significant destinations and amenities. This sub-district will see a range of uses, multi-family, retail, restaurant, and entertainment uses within a range of contexts including retrofitting of single-story commercial buildings and new low- to mid-rise buildings. The objective is to ensure all development and redevelopment is integrated in a manner that prioritizes pedestrian orientation of development and focuses on public improvements. [Figure: Figure 13.1.3-4: Vision for development within the Core Sub-district] [image omitted; see the official ordinance] 5. Special Districts (SD): Special Districts are custom sub-districts established through the creation of any FBZD to accommodate substantially unique developments, such as campus-style, single-destination, or comprehensively planned projects, on parcels exceeding two (2) acres that cannot reasonably conform to any of the base Sub-districts established above. This designation shall maintain the principles and regulating framework for FBZDs, including building form, frontage, and public realm standards, and shall not be used to circumvent the intent of an adopted FBZD. C. Frontage Designations The FBZD Regulating Plans may also designate Type ‘A’, Type ‘B’, Type ‘C’, and/or other Frontages along existing and future streets and blocks. 1. Type ‘A’ Frontages: Intended to provide the most pedestrian-friendly redevelopment context. Buildings and sites along Type ‘A’ designated frontages shall be held to the highest standard of pedestrian-oriented design with doors, windows, active uses, and contiguous building facades along the public sidewalk. 2. Type ‘B’ Frontages: Intended to balance pedestrian comfort and auto-related site elements. These frontages accommodate some surface parking, driveways, and service functions while providing ample public and private sidewalk connectivity between sites. Designated Type ‘B’ Frontages may be developed using Type ‘A’ Frontage standards at the option of the developer. 3. Type ‘C’ Frontages: Do not anticipate a high degree of pedestrian activity such as frontage along multi-lane roadways and highway frontage roads. Development standards are intended to allow flexibility along these frontages. Type ‘C’ Frontages may be developed using Type ‘B’ or Type ‘A’ Frontage standards at the option of the developer. 4. Other Frontages Other types of frontages may be established based on the Regulating Plan. D. Street and Pedestrian Network The Regulating Plan must also establish required and recommended street and pedestrian network, which is intended to create a more walkable street grid as redevelopment occurs. Standards in Section 13.1.8. Street and Sidewalk Standards shall apply. E. Open Space Designations The Regulating Plan may also designate high-profile sites and locations, including environmentally sensitive areas or mature tree stands, as required or recommended open spaces based on the vision for redevelopment within specific areas. F. Special Requirements The Regulating Plan may also designate special requirements unique to achieving the area’s vision such as Terminated Vistas, Colonnade Frontage, Civic Building Requirement, etc. 13.1.4. USE STANDARDS A. Purpose 1. Table 13.1.4-1, Table of Allowed Uses – Base Sub-districts, below lists the uses allowed within each base sub-district. Accessory and temporary uses permitted in the base sub-districts are summarized in Table 13.1.4-1. 2. All uses are defined in Article 12, Definitions. Development or use of a property for any other use that is not specifically allowed in this article, unless permitted by the Texas Local Government Code, is prohibited. 3. Different uses may be permitted with the adoption of FBZDs for different areas or neighborhoods and associated Regulating Plans including the creation of any Special Districts in subsequent sections of this Article. B. Explanation of Table Abbreviations 1. Permitted By-Right Uses “P” in a cell indicates that the use is permitted by right in the respective FBZ Sub-district. Permitted uses are subject to all applicable regulations of this Code, including the supplemental use standards in the UDC and all the requirements of this Article. 2. Uses Requiring a Specific Use Permit “S” in a cell indicates that, in the respective base Sub-district, the use is allowed only if issued a Specific Use Permit, in accordance with the procedures of Section 10.4.6, Specific Use Permits. Uses requiring a Specific Use Permit with the supplemental use standards shall meet the requirements for the supplemental uses in this Article 13 and Section 3.2 Supplemental Use Standards as applicable. 3. Prohibited Uses A blank cell indicates that the use is prohibited in the respective FBZ Sub-district. 4. Supplemental Use Standards There may be supplemental standards that are applicable to a use. The existence of these standards is noted through a cross-reference in the last column of the Allowed Uses Table. Cross-references refer to Section 3.2, Supplemental Use Standards, Section 3.3.6, Supplemental Accessory Use Standards, and Section 3.4.5, Supplemental Temporary Use Standards. An asterisk [*] in a cell indicates that the use, whether permitted by right or as a special use, is permitted subject to supplemental use standards in that district. 5. Allowed Land Uses in Special Sub-districts Land uses in a Special Districts shall be developed in conjunction with FBZDs and corresponding Regulating Plans. C. Table of Allowed Uses TABLE 13.1.4-1: Allowed Uses – Base Sub-districts P = Permitted Use S = Specific Use Permit * = Supplemental Use Standards Apply **SD Uses shall be established in the FBZD standards. | | Base Sub-districts | | | | | Use Category | Use Type | TN | UN | CMU | Core | SD** | Supplemental Use Standards RESIDENTIAL USES | | | | | | | Household Living | Cottage Court | | P | | | | • Standards in Article 13.1.7 shall supersede Standards in Article 5.11 | Dwelling, single-family detached | P | P | | | | | Dwelling, townhouse | P | P | P | P | | | Dwelling, duplex (side-by-side or stacked) | P | P | | | | | Dwelling, multifamily | | | | | | | • Dwelling, triplex (side-by-side or stacked) | P | P | | | | | • Dwelling, fourplex | | P | P | P | | | • Dwelling, mansion apartment (5 – 8 units per building) | | P | P | P | | | • Dwelling, apartment (over 8 units per building) | | P | P | P | | | Dwelling, live/work | | P* | P* | P* | | 3.2.1.A | HUD-code manufactured home | Mobile home | | | | | | Group Living | Assisted living facility (≤6 residents) | P | P | S | S | | | Assisted living facility (≥7 residents) | S | S | S | S | | | Boarding home facility | P* | P* | | | | 3.2.1.B | Community home for disabled persons | P | P | | | | | Foster family home | P | P | | | | | Foster group home | P | P | | | | | Halfway house | | | S | | | | Independent senior living facility | | | P* | P* | | 3.2.1.B.2. (standards b. through d. apply) | Lodging house | fraternity or sorority house | private dorm | | P* | P* | P* | | 3.2.1.B | Nursing home | | | P | | | PUBLIC AND INSTITUTIONAL USES | | | | | | | Community and Cultural Facilities | Art gallery or museum | | P | P | P | | | Correctional facility | | | | | | | Domestic violence shelter | | | P | | | | Emergency shelter | | | P | | | | Government administration and civic buildings | P | P | P | P | | | Mortuary | crematory | funeral chapel | | | P | | | | Philanthropic institution (other than listed) | S | P | P | P | | | Religious assembly | P | P | P | P | | Educational Facilities | Business school | | P | P | P | | | Public or private school | P | P | P | P | | | Trade school | | P | P | P | | | University | college | seminary | | | P | P | | Health Care Facilities | Hospital | | | P | P | | | Hospital, psychiatric | | | S | | | | Medical or dental office or clinic | | P | P | P | | Parks and Open Space | Cemetery | | | | | | | Community garden | P | P | P | P | | | Public park or playground | P | P | P | P | | COMMERCIAL USES | | | | | | | Agriculture | Animal production | | | | | | | Crop production | | | | | | Animal-related Services | Kennel, commercial | | | P* | | | 3.2.3.A | Stables, commercial | | | | | | | Veterinary clinic | | | P | P* | | 3.2.3.A Auto Sales, Equipment, and Repair | Auto service center | | | S* | | | 3.2.3.B and Section 13.1.7 | Auto repair garage, major | | | | | | | Car wash | | | S* | | | 3.2.3.B and Section 13.1.7 | Commercial parking garage | | S | P | P | | | Motor vehicle fueling facility | | | P* | | | • Section 13.1.7 shall apply to the design of fuel pumps and canopy | Motor vehicle rental | | | P* | | | 3.2.3.B | Motor vehicle sales, new | | | P* | | | 3.2.3.B | Motor vehicle sales, used | | | S | | | Financial Services | Bank or Financial Institution | | P* | P* | P* | | 3.2.3.C • Section 13.1.7 shall apply to the design of drive-throughs | Alternative Financial Institution | | | S* | | | 3.2.3.C Food and Beverage Services | Bar | | | P | | | | Catering service | | | P | P | | | Restaurant | | P | P | P | | | Restaurant, take-out and delivery only | | P | P | P | | | Any food service use with drive-through | | | P* | S* | | 3.2.3.D & • Section 13.1.7 shall apply to the design of drive-throughs | Sidewalk cafe | | P* | P* | P* | | 3.3.6.M Lodging Facilities | Bed and breakfast inn | | P* | | | | 3.2.3.E | Hotel, luxury | | | P* | P* | | 3.2.3.E | Hotel, upper upscale | | | P* | P* | | 3.2.3.E | Hotel, upscale | | | S* | S* | | 3.2.3.E | Hotel, upper midscale | | | R* | R* | | 3.2.3.E | Hotel, midscale | | | R* | R* | | 3.2.3.E | Hotel, economy | | | R* | R* | | 3.2.3.E | Hotel, independent | | | | | | | Hotel, convention | | | P* | P* | | 3.2.3.E | Overnight parking facility | | | | | | | Trailer camp | RV park | | | | | | Mixed-Use | Mixed-use development or building | | P | P | P | | Office, Business or Professional | Office, business or professional | | P | P | P | | | Telemarketing call center | | | P | P | | Personal Services | Bail bond service | | | S | | | | Day care center | | P* | P* | P* | | 3.2.3.L | General personal services (other than listed) | | P | P | P | | | Massage therapy clinic | | P | P | P | | | Tattoo parlor or piercing studio | | | P | P | | Recreation and Entertainment, Indoor | Banquet hall | | | S* | S* | | 3.2.3.G • Allowed in existing buildings only | Bingo parlor | | | S* | | | 3.2.3.G | Billiard parlor | | | S* | | | 3.2.3.G | Bowling alley | | | P* | P* | | 3.2.3.G | Game room | | | | | | | Gun range (indoor) | | | S | | | | Nightclub | live entertainment venue | | | S* | P* | | 3.2.3.G | Lodge or fraternal organization | | P | P | P | | | Private club | | | S | | | | Recreation, indoor (other than listed) | | | P* | P* | | 3.2.3.G | Skating rink | | | P* | | | 3.2.3.G | Teen club | | | P* | P* | | 3.2.3.G | Theatre, indoor | | | P* | P* | | 3.2.3.G | Wedding chapel | | | P | S | | Recreation and Entertainment, Outdoor | Country club | | | | | | | Golf course | | | | | | | Gun club, skeet, or target range (outdoor) | | | | | | | Major tourist attraction | | | P | | | | Recreation, general outdoor (other than listed) | | | S | P | | | Marina | | | | | | Retail (Sales) | Boat and accessory sales, rental and service | | | P | | | | Building and landscaping materials and lumber sales | | | P* | | | 3.2.3.I | Farmer’s market | | | | P* | | 3.2.3.I | General retail store (other than listed) | | P | P | P | | • Section 13.1.7 shall apply to the design of drive-throughs for any retail use | Firearm sales | | | P | P | | | Nursery, garden shop or plant sales | | | P* | P* | | 3.2.3.I | Open-air vending | | | P* | P* | | 3.2.3.I | Package liquor store | | | P | | | | Pawn shop | | | P | | | | Second-hand goods store | | | P | | | | Small box discount store | | | S* | S* | | 3.2.3.I | Specialty paraphernalia sales | | | S | | | | Swimming pool, spa and accessory sales and service | | | P* | P* | | 3.2.3.I | Tobacco, e-cigarettes, CHP, or non-traditional smoking-related retail store | | | P* | | | 3.2.3.I Sexually Oriented Business | Sexually oriented business | | | | | | INDUSTRIAL USES | | | | | | | Industrial Service | Building maintenance sales and service | | | | | | | Cleaners, commercial | | | | | | | Flex, Office or Commerce | | | P | | | | Food processing | | | P | | | No single tenant space shall exceed 10,000 square feet in gross floor area. | Heavy machinery rental, sales, and service | | | | | | | Medical or scientific research laboratory | | | P | P | | | Microbrewery | micro-distillery | winery | | | P | P | | | Wrecker service | | | S* | | | 3.2.4.A Manufacturing | Asphalt or concrete batch plant | | | | | | | Custom and craft work | | P* | P* | P* | | 3.2.4.B | Gas well | S* | S* | S* | S* | | 3.2.4.B | High-impact use | | | | | | | Manufacturing and assembly, small-scale | | | P* | | | • No single tenant shall occupy more than 10,000 sq.ft. in a building. | Manufacturing, light | | | | | | | Manufacturing, heavy | | | | | | | Salvage yard (indoor) | | | | | | | Salvage yard (outdoor) | | | | | | Transportation-related Uses | Airport or landing field | | | S | S | | | Heliport | | | | S | | | Overnight truck parking lot | | | | | | | Railroad yard, shop, or roundhouse | | | | | | | Transit passenger terminal | | | P | P | | Utilities | Electric generating plant | | | S | S | | | Electric utility substation | | | P | P | | | Radio or TV station or studio | | | P | P | | | Utility lines, towers or metering station | P | P | P | P | | | Utility installation other than listed | | | S | S | | | Telecommunication Facilities Building-mounted antennae and towers | P* | P* | P* | P* | | 3.2.4.D | Telecommunication Facilities Towers ≤75 ft Stealth towers ≤100 ft | S* | P* | P* | P* | | 3.2.4.D | Telecommunication Facilities Towers >75 ft Stealth towers >100 ft | S* | S* | S* | S* | | 3.2.4.D Wholesale Distribution and Storage | Cold storage plant | | | | | | | Contractors plant, shop and/or storage yards | | | | | | | Distribution center | warehouse | | | | | | | Self-storage facility | | | S* | S* | | 3.2.4.E | Wholesale supply business | | | P | P | | • No single tenant shall occupy more than 10,000 sq.ft. in a building. ACCESSORY USES | | | | | | | Accessory Uses | Accessory building (not listed below) | P* | P* | P* | P* | | 3.3.6.A | Accessory dwelling unit | P | P | P | P | | • Standards in Section 13.1 shall apply | Accessory use (not listed below) | P* | P* | P* | P* | | 3.3.6.A | Alternative energy system | P* | P* | P* | P* | | 3.3.6.B | Caretaker’s quarters | P* | P* | P* | P* | | 3.3.6.C | Carport | P* | P* | P* | | | 3.3.6.D | Community center (private) | S | S | P* | P* | | 3.3.6.A | Customarily incidental use | | P* | P* | P* | | 3.3.6.E | Home-based business | P* | P | P | P | | 3.3.6.H. (2025 Texas Legislation HB2464 will supersede 3.3.6.H) | Electric vehicle charging station | P* | P* | P* | P* | | 3.3.6.O and • Permitted in parking areas only | Garage apartment (see Accessory dwelling unit) | P | P | P | P | | • Standards in Section 13.1 shall apply | Garage (private) | P* | P* | P* | P* | | 3.3.6.A, 3.3.6.G (Core Sub-district only) | Mobile Food Establishment | | | P* | P* | | 3.3.6.N | Outside display and sales | | P* | P* | P* | | 3.3.6.I | Outdoor storage | | | P* | | | 3.3.6.J | Recycling collection center | | | S* | | | 3.3.6.K | Secondary living unit (see Accessory dwelling unit) | P | P | P | P | | • Only standards in Section 13.1 shall apply | Sidewalk cafe | | P* | P* | P* | | 3.3.6.M | Swimming pool (private) | P* | P* | P* | P* | | 3.3.6.P | Transit passenger shelter | | | P | P | | TEMPORARY USES | | | | | | | | Construction field office | P* | P* | P* | P* | | 3.4.5.B | Construction storage yard | P* | P* | P* | P* | | 3.4.5.C | Real estate sales office | P* | P* | P* | P* | | 3.4.5.D | Short term rental | P* | P* | P* | P* | | 3.4.5.E | Carnival, circus, or amusement ride | | | S* | S* | | 3.4.5.A | Temporary Parking Lots | | S* | S* | S* | | • Parking shall meet the parking setbacks along designated Type ‘A’ Frontages. • City Council may establish a time limit on the temporary parking. • Shared parking agreements may be required to allow for public parking at peak times. 13.1.5. STANDARDS APPLICABLE TO ALL SUB-DISTRICTS A. General Standards in this section apply to all development in the base sub-districts and Special Districts in FBZDs. 1. Images and Graphics Images and graphics are provided as visual aids to clarify certain standards and guidelines. They are advisory only and do not carry legal authority. Site design and development illustrations are conceptual, not exact representations, and should be applied based on the property’s actual frontage designations. If a site lacks the frontages shown, only relevant standards apply. While illustrations may include contextual elements, compliance is required only with the standards in the specific subsection referenced. 2. Build-to Zone The Build-to Zone refers to a designated area between the minimum and maximum front setbacks as shown in Figure 13.1.5-1. 3. Frontage Build-Out The Frontage Build-Out is expressed as a percentage of the building’s façade that must be located in the Build-to Zone relative to the width of the lot along the street, as shown in Figure 13.1.5-1. a. The Frontage Build-Out may be comprised of multiple buildings on the same lot. b. Elements such as courtyards, forecourts, plazas, paseos, sidewalk cafes, and other amenities that engage the street shall count towards the calculation of Frontage Build-Out. c. Semi-enclosed outdoor spaces as outlined in Section 13.1.7.C.4., may count for up to 25% of the required Frontage Build-Out. d. Parking, driveways, service, and utility functions shall NOT count toward the calculation of Frontage Build-Out. [Figure: Figure 13.1.5-1: Three-dimensional diagram illustrating Frontage Build-Out and Build-to-Zone.] [image omitted; see the official ordinance] 4. Phasing for Frontage Build-Out: If a development cannot meet the Frontage Build-Out requirement, a phasing of the required Frontage Build-out may be considered with a Minor Modification. For such consideration, the first phase of development must locate the building along the lot’s highest level frontage designation. Where a corner lot is bordered by two Type ‘A’ Frontages, the initial phase must be located on the street having higher pedestrian-oriented development based on the Zoning Administrator’s assessment. 5. Minimum front setback: The minimum front setback shall be the greater value of the following standards: a. The minimum front building setback as required in the Sub-district Standards; or b. The minimum building setback as required to meet the street and sidewalk standards in Section 13.1.8.C. and 13.1.8.D., including requirements for a Furnishing Zone and a Clear Sidewalk Zone. c. The minimum setback required for ground floor residential based on street type. 6. Measuring Build-to Zones and Setbacks a. When sidewalks extend on to private property, build-to zones and setbacks may be measured from behind the sidewalk closest to the building façade along the street. b. All sidewalks shall be within designated public access easements and in no case shall there be any surface parking or service functions located between the sidewalk and the building façade along any areas required to meet the frontage build-out requirements. 7. Encroachments a. All encroachments into the minimum setback areas along streets shall meet standards in Section 5.7.4.B Architectural Setback Encroachments. b. Building projections on all other façades must not be closer than 5 feet to any adjacent property line. 8. Building Height Measurement: Building heights shall be measured according to the standards established in UDC Section 4.1.7. 9. Building Height Transitions: A building’s height shall not exceed 45 feet within the first 75 feet of a shared property line with TN sub-district or any existing single-family residential zoning district located outside an FBZD. Beyond 75 feet, the maximum building height shall be the Sub-district’s maximum building height. Also see Section 13.1.9.B.5. for applicable screening requirements for the same. [Figure: Figure 13.1.5-2: Building Height Transitions.] [image omitted; see the official ordinance] B. Parking Configuration: This section defines the range of site layouts that can be applied to parking and building placement. Please consult the Form Standards for each Sub-district to understand the permitted parking configurations. Table 13.1.5-1: Parking Configuration NOTES | a. For permitted site configurations within each Sub-district, see the Sub-district Site Development Standards which follows this Table. b. These diagrams illustrate fundamental building and parking layouts. c. The highest street type classification (Type ‘A’ > Type ‘B’ > Type ‘C’) for any given lot must be the Primary Street. d. Refer to Building Design, Section 13.1.7.D. for allowable parking and garage configurations in the TN Sub-district. LEGEND | BUILDING(S), PARKING, PROPERTY LINE, FRONTAGE BUILD-OUT [legend symbols omitted; see the official ordinance] REAR PARKING (Required along Type ‘A’ Frontages and allowed along all other frontages) | [Figure: rear parking site layout diagram] [image omitted; see the official ordinance] | 1. Parking is located to the rear of the building. 2. Required cross access easements between properties. 3. Corner lots to position building on the street corner side. 4. Shared curb cut preferred and limit curb cuts along Type ‘A’ or Primary Street frontages. SIDE PARKING (Allowed ONLY along Type ‘B’ or ‘C’ Frontages; Allowed on Type ‘A’ Frontages with a Minor Modification*) | [Figure: side parking site layout diagram] [image omitted; see the official ordinance] | 1. Parking on one side of building, and rear (optional). 2. Required cross access easement between properties. 3. Corner lots to position building on the street corner side. 4. Shared curb cut preferred and limit curb cuts along Type ‘A’ or Primary Street frontages. | | *Side parking may be allowed on Type ‘A’ Frontages with a Minor Modification. Parking setbacks apply along the Type ‘A’ Frontage. PARKING WITH MULTIPLE BUILDINGS (Allowed ONLY along Type ‘B’ or ‘C’ Frontages) | [Figure: multiple-building parking site layout diagram] [image omitted; see the official ordinance] | 1. Parking located on the side, rear or between multiple buildings (in the middle of the block). 2. Required cross access easements between properties or pad sites. 3. Corner lots to position building on the street corner side. PERIMETER PARKING (Allowed ONLY along Type ‘C’ Frontages and Access ways) | [Figure: perimeter parking site layout diagram] [image omitted; see the official ordinance] | 1. Parking permitted on all sides of building and rear. A single lane for driving is allowed between the building and the street, but parking is not permitted directly in front of the building. 2. Required cross access easements between properties. 3. Building set back from street. 4. Shared curb cut preferred 13.1.6. BASE SUB-DISTRICT STANDARDS This section establishes the site development standards for the four base Sub-districts. In the event that new Sub-districts are required, their standards will be developed to align with the FBZDs and corresponding Regulating Plans. This alignment will follow the format of the base Sub-districts established in this section. The aim is to ensure a consistent and coherent approach to the development of any new Sub-districts, while upholding the principles of the form-based zoning districts across the city. A. Traditional Neighborhood (TN) Table 13.1.6-1 TN Traditional Neighborhood Standards | TN: TRADITIONAL NEIGHBORHOOD [Figure: lot diagram showing setbacks, build-to zone, and frontage] [image omitted; see the official ordinance] Note: Sidewalks, landscaping, windows, screening and other site and building improvements not shown for clarity Street Frontage Building Setbacks (min. and max. setbacks – see Note 1) BTZ | Primary Street (A > B > C Frontage Types) | 10’ (min.) – 25’ (max.) (see Note #2) | Secondary Street (corner lot) | 5’ (min) – 20’ max (See Note #2) Side and rear yard building setbacks C | Side / Rear – for all Neighborhood building types (minimum) | 5’, except townhouse shall have 0’ min side setback for interior units Frontage Build-out – refer to Regulating Map for frontage type designations F | Type ‘A’ Frontage (minimum) | 50% | Type ‘B’ Frontage (minimum) | 0% | Type ‘C’ Frontage | 0% Building Height H | Maximum building height | Shall be established in the specific FBZD standards Permitted Parking Configurations | See Section 13.1.7.C.2.b Parking Area Setbacks (applies to surface parking spaces and garages) P | Front (minimum) | Must be behind front façade. See Section 13.1.7.C.2.b P | Street, Side setback (minimum) | 5’ (screened by landscaping or others) P-C | Interior, Side/rear setback (minimum) | 3’ Permitted Building Types Single-Family Detached | Duplex | Triplex | (Maximum Building Width: 60 feet) Single-Family Attached (Townhouse) Accessory Building | Accessory Dwelling Unit (ADU) Lot Standards Minimum 1,500 SF of lot area required for each dwelling unit (accessory residential units shall be treated as a dwelling unit for the purposes of this calculation). Minimum lot width (All residential building types except Townhouse) : N/A Minimum lot width (Townhouse): 20 feet Notes: 1. Minimum and maximum setbacks are only required for the portion of the building required to meet the Frontage Build-out standards in all districts. 2. Zoning Administrator may adjust the minimum setback by Minor Modification based on setbacks of existing buildings along a block. B. Urban Neighborhood (UN) Table 13.1.6-2 UN Urban Neighborhood Standards | UN: URBAN NEIGHBORHOOD [Figure: lot diagram showing setbacks, build-to zone, and frontage] [image omitted; see the official ordinance] Note: Sidewalks, landscaping, windows, screening and other site and building improvements not shown for clarity Street Frontage building setbacks (min. and max. setbacks – see Note 1) BTZ | Type ‘A’ Frontage | 5’ (min.) – 20’ (max.) | Type ‘B’ Frontage | 5’ (min.) – 20’ (max.) | Type ‘C’ Frontage | 5’ (min.) – no max. Side and rear yard building setbacks C | Side / Rear – for all Neighborhood Building Types (minimum) | 5’, except townhouse would have 0’ min side setback for interior units C | Side / Rear – for Urban Building Types (minimum) | 10’; 20’ when adjacent to TN Sub-district or single-family zoning district outside the FBZD Frontage Build-out – refer to Regulating Map for Frontage Designations F | Type ‘A’ Frontage (minimum) | 60 % F | Type ‘B’ Frontage (minimum) | 40% F | Type ‘C’ Frontage | 0% Building Height H | Minimum Building Height shall be established in the FBZD standards and associated Regulating Plans | Height Transitions in Section 13.1.5.A.8 shall apply Permitted Parking Configurations (refer to Table 13.1.5-1) | Rear Parking, Side Parking, Parking with Multiple Buildings Parking Setbacks P | Front (minimum) | 15’ P | Side street (minimum) | 5’ P-C | Setback when adjacent to commercial/mixed-use district (minimum) | 2’ | Setback when adjacent to single-family residential zoning district (minimum) | 10’ Permitted Building Types All permitted in TN, Fourplex, Mansion Apartment, Cottage Court, Urban Building Types Single-Family Detached | Duplex | Triplex | (Maximum Building Width: 60 feet) Lot Standards Minimum lot width (all building types, except Townhouse): N/A Minimum lot width (Townhouse): 20 feet Notes: 1. Minimum and maximum setbacks are only required for the portion of the building required to meet the Frontage Build-out standards. 2. Minimum shall not be less than that required to meet sidewalk standards and requirements for ground floor residential treatment in Section 13.1.7.D.2.c. C. Corridor Mixed-Use (CMU) Table 13.1.6-3 CMU Corridor Mixed-Use Standards | CMU: CORRIDOR MIXED-USE [Figure: lot diagram showing setbacks, build-to zone, and frontage] [image omitted; see the official ordinance] Note: Sidewalks, landscaping, windows, screening and other site and building improvements not shown for clarity Street Frontage Build-to Zones (min. and max. setbacks – see Note 1 and 2 below) BTZ | Type ‘A’ Frontage | 5’ (min.) – 20’ (max.) | Type ‘B’ Frontage | 5’ (min.) – 20’ (max.) | Type ‘C’ Frontage | 5’ (min.); no max. Side and rear yard building setbacks C | Side / Rear – for all Neighborhood Building Types (minimum) | 5’, except townhouse would have 0’ min side setback for interior units C | Side / Rear – for Urban Building Types (minimum) | 0’ (fire separation standards apply); 20’ when adjacent to TN Sub-district or single-family zoning district outside the FBZD Frontage Build-out – refer to Regulating Map for Frontage Designations F | Type ‘A’ Frontage (minimum) | 60% | Type ‘B’ Frontage (minimum) | 40% | Type ‘C’ Frontage | 0% Building Height H | Maximum Building Height shall be established in the FBZD standards and associated Regulating Plans | Height Transitions in Section 13.1.5.A.8 shall apply Permitted Parking Configurations (refer to Table 13.1.5-1) | Rear Parking, Side Parking, Parking with Multiple Buildings Parking Setbacks P | Front (minimum) | 25’ P | Side Street (minimum) | 5’ P-C | Setback when adjacent to commercial/mixed-use district (minimum) | 2’ | Setback when adjacent to single-family residential zoning district (minimum) | 10’ Permitted Building Types Fourplex, Mansion Apartment, Townhouse, Urban Building Types Lot Standards Minimum lot width (All building types except Townhouse): N/A Minimum lot width (Townhouse): 20 feet Notes: 1. Minimum and maximum setbacks are only required for the portion of the building required to meet the Frontage Build-out standards. 2. Minimum shall not be less than that required to meet sidewalk standards and requirements for ground floor residential treatment in Section 13.1.7.D.2.c. D. Core (C ) Table 13.1.6-4 C Core Standards | C: CORE [Figure: lot diagram showing setbacks, build-to zone, and frontage] [image omitted; see the official ordinance] Note: Sidewalks, landscaping, windows, screening and other site and building improvements not shown for clarity Street Frontage Build-to Zones (min. and max. setbacks – see Note 1 and 2 below) BTZ | Type ‘A’ Frontage | 0’ (min.) – 12’ (max.) | Type ‘B’ Frontage | 0’ (min.) – 12’ (max.) | Type ‘C’ Frontage | 0’ (min) Side and rear yard building setbacks C | Side / Rear (minimum) | 0’ (fire separation standards apply) C | Side / Rear (adjacent to TN Sub-district or single-family zoning outside the FBZD) (minimum) | 20’ Frontage Build-out – refer to Regulating Map for Frontage Designations F | Type ‘A’ Frontage (minimum) | 70% | Type ‘B’ Frontage (minimum) | 50% | Type ‘C’ Frontage | 0% Building Height H | Maximum Building Height shall be established in the FBZD standards and associated Regulating Plans | Height Transitions in Section 13.1.5.A.8 shall apply Permitted Parking Configurations (refer to Table 13.1.5-1) | Rear Parking, Side Parking (with Minor Modification), Parking with Multiple Buildings Parking Setbacks P | Front (minimum) | 25’ (or 3’ behind front façade) P | Side Street (minimum) | 5’ P-C | Setback when adjacent to commercial/mixed-use district (minimum) | 2’ | Setback when adjacent to single-family residential zoning district (minimum) | 10’ Permitted Building Types Fourplex, Mansion Apartment, Townhouse, Urban Building Types Lot Standards Minimum lot width (All residential building types except Townhouse): N/A Minimum lot width (Townhouse): 20 feet Minimum lot width (All other): 50 feet Notes: 1. Minimum and maximum setbacks are only required for the portion of the building required to meet the Frontage Build-out standards. 2. Minimum shall not be less than that required to meet sidewalk standards and requirements for ground floor residential treatment in Section 13.1.7.D.2.c. 13.1.7. BUILDING DESIGN STANDARDS A. Intent A building’s design and appearance play an important role in the overall character of a street, neighborhood or district. The standards in Section 13.1.7 balance the desire for individual architectural design while still recognizing a shared community vision. The building design standards in this section intend to: 1. Establish basic design standards to produce attractive development while still allowing flexibility for creative building solutions; 2. Enhance the visual appeal and cohesiveness of buildings along public thoroughfares, contributing to the area’s character as redevelopment occurs; 3. Promote designs that are well-suited to the local climate, incorporating light-colored materials, shade-providing features, and partially enclosed outdoor areas; 4. Where applicable, considering design that honors a neighborhood’s historic context should be prioritized; 5. Ensure that buildings have entrances that are oriented toward the street and sidewalk to promote pedestrian activity along the corridors; 6. Utilize ample windows (glazing), to provide visual interest and interaction between the exterior and interior of the building, which is also good for business. 7. Examples of design elements intended to achieve the above goals and which are included in this section are illustrated in Figure 13.1.7-1. [Figure: Figure 13.1.7-1: Illustrative images that represent high quality building design at a variety of scales which would be appropriate in various Sub-districts.] [image omitted; see the official ordinance] B. Applicability and Organization 1. Applicability Building design standards, when applicable based on Section 13.1.1.E together with any adopted in the FBZDs standards, shall apply to all building facades including facades that face: a. All streets, alleys, accessways, cross access easements; b. All usable open space such as a square, plaza, or courtyard; and c. All parking lots. 2. Organization For organizational purposes, Building Design Standards are hereby categorized into two (2) primary building types: “Neighborhood Building Type” and “Urban Building Type.” C. Neighborhood Building Type Standards 1. Applicable Neighborhood Building Types (See Figure 13.1.7-2 and Table 13.1.7-3) a. Single-Family Detached | Duplex | Triplex | Fourplex | Mansion Apartment b. Single-Family Attached (Townhouse) c. Accessory Building | Accessory Dwelling Unit (ADU) d. Cottage Court [Figure: Figure 13.1.7-2 Examples of Neighborhood Building Types] [image omitted; see the official ordinance] Table 13.1.7-3 Neighborhood Building Type Standards [Figure: three-dimensional diagram of detached house with garage] [image omitted; see the official ordinance] | [Figure: three-dimensional diagram of attached townhouse row] [image omitted; see the official ordinance] | [Figure: three-dimensional diagram of accessory buildings] [image omitted; see the official ordinance] SINGLE-FAMILY, DUPLEX, TRIPLEX | ATTACHED RESIDENTIAL BUILDING (TOWNHOUSE) | ACCESSORY BUILDINGS A residential structure which is set back from the side and rear property lines. | Attached single-family dwelling units on separate lots that share at least one common party wall. | Accessory buildings, including garages (with or without accessory dwelling units) and storage sheds which are located at the rear of the property behind the principal building. 2. General Design Standards for All Neighborhood Building Types a. Dwelling Unit Entries: (i) Each dwelling unit shall have its own individual entry on the ground level. (ii) At least one dwelling unit entry shall face the primary street and shall have a walkway connecting the entry to the public sidewalk along that street. (iii) Exterior hallways and stairs are not permitted. (iv) Dwellings may also have entries from an internal courtyard or pedestrian paseos that are dedicated as common open space or with pedestrian access easements. (see Cottage Court Standards in Section 13.1.7.C.3.b. below). (v) Lots platted on individual lots (or cottage sites, if not platted as individual lots) must have their main entrances from the primary street or pedestrian paseo or pedestrian access easement unless a minor modification is approved for alternative entry approvals b. Garage placement (i) Intent: To preserve the character of the neighborhood street and enhance pedestrian safety in residential areas, garages should be located behind the house whenever possible. (ii) Table 13.1.7-4 shows permitted Garage Placement for Detached Residential Buildings based on lot width and street context (mid-block lot vs corner lot), with additional criteria as follows: (1) Garages may be connected to the house with an enclosed space or detached from the house. (2) Front facing garages as shown in Scenario 4 of Table 13.1.7-4, are limited to a single-bay garage door no more than 10 feet wide and 8 feet tall. The garage door shall be set back a minimum of 4 feet from the primary façade of the house (not including porches and stoops). (3) Garages facing a secondary street are limited to a two-bay garage with a garage door opening of no more than 18 feet. (4) Driveways leading to rear garages are limited to 12' wide at the street curb-cut and the full depth of the front yard setback. (iii) Table 13.1.7-5 shows permitted location of garages for Attached Residential Buildings (Townhouses). Townhouses shall not have garages facing the side property line nor shall they face a secondary street on corner lots. A Minor Modification to allow parking along the side may be considered if: (1) The portion of the home located within 70 feet of Primary Street is oriented toward the front; OR (2) The design incorporates a wrap-around porch that clearly presents a front-facing appearance; AND (3) A wing wall (an extension of the building façade) is provided to screen the garage and driveway area. Table 13.1.7-4 Garage Placement for Detached Neighborhood Buildings [Figure: diagrams of five garage placement scenarios on lots] [image omitted; see the official ordinance] LEGEND: G=GARAGE, W=LOT WIDTH, D=LOT DEPTH (assumed to be minimum 100' deep), P=PERMITTED, Blank = NOT PERMITTED LOT WIDTH (W) | 1 CORNER LOT – REAR GARAGE FACING SECONDARY STREET | 2 INTERIOR LOT – REAR GARAGE FRONT APPROACH | 3 INTERIOR LOT – REAR GARAGE SIDE APPROACH | 4 FRONT GARAGE See Note (a) | 5 REAR GARAGE ON ALLEY (A) See Note (b) ≤45' | P | P | | P | P >45', <50' | P | P | | | P ≥50' | P | P | P | | P All other lots and conditions | See Note (c) | | | | NOTES: (a) Refer to Section 13.1.7.C.2.b for additional criteria applicable to front-facing garages. (b) Use of alley (A) for garage access subject to City of Arlington Public Works approval. (c) For lots that do not meet the above dimensional standards, the Administrator shall determine the applicable garage placements. Table 13.1.7-5: Garage Placement for Attached Neighborhood Buildings [Figure: diagram of townhouse garages behind building with driveway loop] [image omitted; see the official ordinance] | [Figure: diagram of townhouse garages accessed from rear alley] [image omitted; see the official ordinance] | [Figure: diagram of townhouse garages facing side, crossed out] [image omitted; see the official ordinance] 1 | 2 | 3 GARAGE SCENARIO 1: For townhouses that do not have alley access from the rear, provide a driveway loop to access garages at the rear of the property. This configuration requires a shared easement between the townhouse lots to maintain access for all units. | GARAGE SCENARIO 2: Where there is an existing alley (A), and subject to approval by the City of Arlington, Department of Public Works, townhouses may have rear garages accessed from the alley. | GARAGE SCENARIO 3: This configuration, which has garages facing the side property line, and visible from the street and adjacent properties, is NOT PERMITTED unless a Minor Modification under Section 13.1.7.C.2.b.iii is approved. c. Architectural Design (i) Roof forms: utilize traditional, sloped roofs forms as shown in Figure 13.1.7-6. (1) Shed roofs, sloping in one direction, are permitted for smaller roof structures including porch roofs, entry features, dormers, and one-story volumes at the rear of the building. (2) Primary roof forms over habitable spaces shall be sloped a minimum of 6:12 (vertical to horizontal). (3) Porch roofs, and minor appendages (sunrooms, rear mud rooms, bay windows, etc.) may be sloped a minimum of 2:12 (vertical to horizontal). (4) Front facades shall not incorporate more than two gables facing the street. (5) Flat roofs, with or without parapet walls are not permitted except behind the building (except in CMU and Core Sub-districts). (6) Other roof forms may be permitted with approval of a Minor Modification based on the architectural style of the building. Figure 13.1.7-6 Roof Forms for Neighborhood Building Types [Figure: gable roof diagram] [image omitted; see the official ordinance] | [Figure: hip roof diagram] [image omitted; see the official ordinance] | [Figure: gambrel roof diagram] [image omitted; see the official ordinance] GABLE ROOF | HIP ROOF | GAMBREL ROOF [Figure: dutch gable roof diagram] [image omitted; see the official ordinance] | [Figure: jerkinhead roof diagram] [image omitted; see the official ordinance] | [Figure: saltbox roof diagram] [image omitted; see the official ordinance] DUTCH GABLE | JERKINHEAD ROOF | SALTBOX (Asymmetrical Gable) (ii) Architectural features: Architectural features must be incorporated into street facing facades to enhance neighborhood character and visual interest along the street. Acceptable architectural features are represented in Table 13.1.7-7, and are required as follows: (1) Each detached or attached residential unit facing a street shall have at least one entry feature and one window feature facing the street. If a front porch of a minimum area of 50 square feet and minimum depth of 6 feet is provided, the window feature is not required. Architectural features may be repeated on the façade when associated with individual dwelling units (e.g. A duplex may have two identical enhanced entries). (2) Corner lots: Any residential building type that is situated on a corner lot shall incorporate either a wrap-around porch (minimum of 75 sq.ft.) facing both streets or one additional architectural feature on the façade facing the secondary street and comply with the minimum glazing standards for a front-facing façade. Table 13.1.7-7 Architectural features for Neighborhood Building Types The following images are illustrative and not necessarily intended to be duplicated exactly as shown. ENTRY FEATURES [Figure: elevation of porch entry] [image omitted; see the official ordinance] | [Figure: elevation of arched entry door and stoop] [image omitted; see the official ordinance] | [Figure: elevation of enhanced entry door and stoop] [image omitted; see the official ordinance] Porch (min. 50 SF in area, and minimum 6 feet clear depth) | Arched entry door and stoop (masonry façade only) | Enhanced entry door and stoop (with side lights and transom) WINDOW FEATURES [Figure: elevation of roof dormer with window] [image omitted; see the official ordinance] | [Figure: elevation of triple window grouping] [image omitted; see the official ordinance] | [Figure: elevation of bay window] [image omitted; see the official ordinance] Roof dormer with windows | Triple window grouping | Bay window d. Exterior finish materials (i) 360-degree architecture: The primary material on the front façade shall be continued on all sides of the house, and on at least 50% of each side. (ii) To reinforce the historic character of Arlington’s historic and traditional neighborhoods, exterior finish materials shall be include the following: (iii) Exterior walls shall be finished with brick, stone (native to Texas), three-coat stucco, wood lap siding, board and batten wood, Cementitious Fiber Board (board and batten or lap siding) (iv) Exposed foundation walls shall be finished in brick, stone (native to Texas), or three-coat stucco over concrete or concrete masonry units. (v) All public-facing facades must include a minimum transparency (glass windows and doors) of 20 percent. 3. Additional Standards for Specific Neighborhood Building Types a. Accessory Dwelling Unit (ADU): (i) ADUs shall be any dwelling unit 800 sq.ft. or under in conjunction with a primary dwelling unit on the same lot. (ii) It shall be counted towards the maximum number of dwelling units permitted on the lot; however, for the purposes of calculating number of parking spaces required, only one (1) parking space shall be required per each ADU. (iii) Accessory dwelling units may be located within or attached to the main structure on the lot or in a detached structure on the lot or with a garage. b. Cottage Court Standards: The following standards shall apply to Cottage Courts in the UN sub-district (See Table 13.1.7-8). (i) Units: min. 3 units, max. 12 units (each unit shall require 1,200 sq.ft. of land area) clustered around a single paseo or open space; Additional units may be clustered around additional open space and/or paseos with units oriented around them. (ii) Maximum unit size shall be 1,200 sq.ft. for one story units and 2,000 sq.ft. for 2 story units. (iii) Height shall be 2.5 stories max. (iv) Building types permitted: detached residential buildings or attached residential buildings. In no case shall the attached units exceed a building with a footprint over 2,000 sq.ft. (v) Units may be platted on individual lots or all on the same lot. (vi) Perimeter setbacks and build-to zones shall be the same as in Sub-district standards in 13.1.6. Interior setbacks shall be based on fire separation standards. (vii) A minimum of 15% of the site area shall be dedicated to a common open space, courtyard, or paseo with all the units facing either the common open space, courtyard or paseo or a public street (or combination thereof). (viii) Dwelling units facing a shared green or shared easement shall meet design requirements for a street-facing façade. (ix) Off-street parking (garages or surface parking) shall be located in such a manner as to minimize frontage along Type ‘A’ or ‘B’ streets, other residential units or adjoining properties. Table 13.1.7-8 Cottage Court Standards The illustrative plan shows a cottage court development with individually platted lots. For rental units, individual lots are not required to be platted but the site design shall be treated the same as a development with individually platted lots. Dwelling units may be attached or detached (townhouses). Allowed only in the UN District. [Figure: illustrative plan of a cottage court development, numbered 1 to 5] [image omitted; see the official ordinance] 1 | Cottage lots must front on a street or courtyard, open space (platted as a separate lot or shared easement). 2 | Sub-district lot setbacks apply to outside units. 3 | Building -to-building setbacks governed by building/fire code. 4 | Dwelling units facing a shared green or shared easement shall meet design requirements for a street-facing façade. 5 | Place parking at the rear (attached or surface parking lot) or adjacent to the lowest street frontage type if site is bound by more than two streets. D. Urban Building Type Standards 1. Applicable Urban Building Types a. Multi-story (Apartment Building | Mixed-Use | Commercial Building); b. High-rise (more than 6 stories); c. One-story non-residential; d. Civic and Religious e. Auto-Oriented site (Drive-Through Window | Fuel Station), and f. Multi-Level Parking Garage. 2. General Design Standards for all Urban Building Types a. Building Orientation and Access (i) Building entrances should be placed along the public sidewalk. Where not feasible, entrances should be visible from a public sidewalk and must be provided with an accessible sidewalk that connects the public sidewalk to the building entrance. (ii) Building entrances must be located as follows: (1) Building entrances shall have their primary entrance directly from the street frontage type with the highest designation (A > B > C) or through a recessed area, courtyard or plaza connected to the primary street. (2) Building entrances may be located on the corner at a 45-degree angle. (3) Alternate locations for building entries in the Corridor Mixed-Use (CMU) Sub-district only: (a.) Entrances may be located on the side of a building facing a side parking lot or access driveway if that side of the building includes windows and design features similar to the front of the building, and where the entrance is connected to a public sidewalk meeting the standards of Section 13.1.8. (b.) Entrances may face a covered or open breezeway or alley between two buildings so long as the entrance is connected to the public sidewalk and the side or rear parking. (4) Secondary entrances are allowed on any other side of a building. b. Architectural Treatment of Building Entries (i) The primary entryway shall be readily apparent as a prominent architectural component from the street, thus creating a focal point. Nonresidential buildings with multiple tenants on the ground floor or multiple primary entrances shall have all entrances treated architecturally. (ii) Primary building entrances are to be defined and articulated with architectural elements such as pediments, columns, porticos, porches, and overhangs. (iii) Entries that face a public sidewalk shall enter at the level of the sidewalk, unencumbered by ramps and stairs between the sidewalk and the entry door. Floor level transitions shall be accommodated inside the building. (iv) All ground-floor entrances shall be covered or inset. This requirement shall not apply to loading areas. (v) Out-swinging doors shall be recessed or set back so as not to encroach into the Sidewalk Clear Zone. c. Ground Floor Residential Frontage Treatment: (i) All residential units located on the ground floor level must have at least one door to the public sidewalk or street. (ii) The entrance must be recessed into the building or shaded with a permanent canopy or overhang at least 36” deep and include a paved stoop of at least 48” wide by 42” deep. (iii) Patios, porches, and other outdoor amenities are also encouraged to add character and pedestrian enjoyment. (iv) Residential uses at the ground floor level are subject to minimum setbacks and fence requirements based on street type that supersedes minimum setbacks by sub-district (see Table 13.1.7-9). (v) Fence standards for Arterial and Urban Arterial Roadway Frontage (see Table 13.1.7-9) must include: (1) Height of the fence: Min. 30”, max. 42” (2) Construction Material: A metal fence, with openings between pickets of 3” to 6”. The fence may have a masonry base of a maximum of 18” above grade with a metal picket fence above or consist of a masonry wall that is a minimum of 24” tall. Chain link fences are not permitted. (3) The fence/wall shall have periodic gates or openings at a spacing of no less than 100 feet to facilitate pedestrian access for residents. The gates may have locking mechanisms to control access. Table 13.1.7-9: Ground Floor Residential Frontage Treatment (Applicable to all Sub-districts except Traditional Neighborhood TN) [Figure: section view of sidewalk, frontage zone and fence] [image omitted; see the official ordinance] | | [Figure: section view of sidewalk and frontage zone] [image omitted; see the official ordinance] | Above: Section view along a street classified as an Arterial or Urban Arterial Roadways with ground floor residential use. | | Above: Section view along all other streets with ground floor residential use. | SW | Sidewalk as required in Section 13.1.8. | SW | Sidewalk as required in Section 13.1.8. FR-R | Min. 12 feet from edge of sidewalk to building façade. The Frontage Zone may be paved with concrete or pavers for a maximum of 50%. | FR-R | All other streets: Min. 7 feet The Frontage Zone may be paved with concrete or pavers for a maximum of 50%. E | Encroachments: Porches, entries and balconies may encroach up to 5 feet in the frontage zone. Steps and roof overhangs may encroach an additional 2 feet. | E | Encroachments: Porches, entries and balconies may encroach up to 5 feet in the frontage zone. Steps and roof overhangs may encroach an additional 2 feet. F | Provide a physical barrier (fence), between the sidewalk and Frontage Zone as described above. | | d. Transparency (i) Intent: Transparency refers to the design and integration of doors, windows, and other openings within the exterior walls of a building. These standards require that building facades which are visible from streets must incorporate a minimum percentage of windows and doors to enhance the streetscape, fostering a sense of liveliness and vigilance that promotes pedestrian engagement. It explicitly prohibits the construction of blank walls on facades that face public streets, thus maintaining an interactive and inviting environment. (ii) Applicability: Transparency standards in Figure 13.1.7-10 shall apply as follows: (1) Where a primary facades faces a public street that have a Type ‘A’ or ‘B’ frontage designation, or; (2) Where a façade faces a pedestrian way or paseo with a public access easement, or; (3) Where a façade faces a side or front parking lot which is visible from the street. (4) A façade that is not visible from a public street, or that faces an alley or access way, is not required to meet minimum fenestration standards but may be required to imitate the rhythm of windows and doors in its façade treatment. Figure 13.1.7-10: Transparency Requirements Values expressed as a percentage of glazing area to wall area (including glazing), measured according to diagram below. GLAZING REQUIREMENTS | Ground Floor Commercial | Min. 30%; Max. 80% | Residential (all floors), and non-residential (upper floors): | Min. 20%; Max. 80% [Figure: building elevation showing glazing measurement zones by floor] [image omitted; see the official ordinance] [Figure text: GLAZING FOR UPPER FLOORS: Glazing measured from finish floor level to a height of 10 feet above finish floor. | GLAZING FOR GROUND FLOOR: Glazing measured from floor level to a height of 12 feet above finish floor (also applies to 1-story buildings) | Note: windows do not have to be evenly spaced] Notes: 1. Opaque doors are not counted towards the calculation of transparency. 2. Glazing area may include window frames, mullions, muntins, and structural members that are less than 8” in width. (iii) Window Configuration: The following window shapes are NOT permitted (See Figure 13.1.7-11): (1) Horizontally banded windows (i.e., ribbon windows), where the horizontal window dimension is more than 1.5 times the window height. Different window configurations may be permitted with the approval of a Minor Modification based on windows’ consistency with the architectural style of the building. (2) All-glass facades are not permitted unless permitted in the area-specific Form-based Zoning District Standards. (iv) Window Glass: glass shall not be heavily tinted or reflective (e.g., no mirrored glass), and shall meet the following criteria: (1) Min. visible transmittance of 60% (lower transmittance may be allowed if energy code targets can be achieved through a Minor Modification). (2) Max. exterior visible reflectance of 15%. [Figure: Figure 13.1.7-11: Horizontally banded windows and all-glass walls do not add to the character of the corridor and are not permitted.] [image omitted; see the official ordinance] e. Semi-Enclosed Open Spaces (i) Semi-enclosed open spaces, such as patios, pergolas, trellises, columned arcades; and outdoor areas covered by a permanent roof or trellis structure, may count for up to 25% of the Frontage Build-out requirements in Section 13.1.6. The semi-enclosed open space shall have a depth of at least 8 feet measured to the outside of the supporting columns. Facades that face a semi-enclosed open space shall meet the minimum transparency requirements in Section 13.1.7.D.2.d. (See Figure 13.1.7-12) below). [Figure: Figure 13.1.7-12: Examples of semi-enclosed open spaces] [image omitted; see the official ordinance] f. Shading Devices (i) Intent: The provision of shade for public walkways, particularly those adjacent to Type ‘A’ and ‘B’ Frontages, is crucial for promoting pedestrian use. Additionally, architectural elements that provide shade contribute to the visual interest of the streetscape. (ii) Shading Requirements: shall be provided with the use of shading devices such as metal canopies, overhangs, and awnings as shown in Figure 13.1.7-14. The extent of shading shall be quantified relative to the length of the building's façade and must adhere to the following stipulations: (1) Facades along a Type ‘A’ Frontage designation, as identified in the Regulating Plan, must have shading devices along at least 50% of its Type ‘A’ Frontage (including all doors and windows along that frontage) (see Figure 13.1.7-13). (2) Facades along a Type ‘B’ Frontage designation, as indicated on the Regulating Plan, must have shading devices along at least 25% of its Type ‘B’ Frontage (including all doors and windows along that frontage) (see Figure 13.1.7-13). (3) Pedestrian Connections and on-site pedestrian walkways as required in Section 5.9 of the UDC shall have shading devices and/or street trees for shade as required in this Section. (4) Shading structures must maintain a minimum clearance of 8 feet above the ground and project outward from the building's exterior wall by at least six feet. (5) Placement of shading structures should prioritize areas above the main entrance and the largest sections of windows. (6) Buildings with ground-level residential units shall have a shading device located at residential entry doors. (7) Any projection of shading structures into public spaces (ROW) must enter into an encroachment agreement. [Figure: Figure 13.1.7-13: Minimum Dimensions for Shading Devices.] [image omitted; see the official ordinance] [Figure text: ‘A’ Frontage: S = 50% of L (min.) | ‘B’ Frontage: S = 25% of L (min.) | 6' MIN. | 8' MIN.] (iii) Shading devices may include the following: (1) Awnings: awnings shall extend a minimum of 6 feet from the façade and a minimum vertical clearance of 8' (see Figure 13.1.7-13) and shall be canvas or fabric. Vinyl or plasticized materials, and internally illuminated awnings, are not permitted. (2) Suspended Metal Canopies: shall extend a minimum of 6 feet from the façade and shall be constructed of metal. (3) Galleries shall be a minimum of 8 feet deep measured from the primary wall material to the inside of the face of the column. Clear height shall be minimum 10 feet. The roof plane shall appear as a shallow plane of 12” or less in depth which may be sloped up to 4:12. Roofs shall not have drop soffits. Columns shall be proportional to the roof mass (see Figure 13.1.7-14). (4) Roof Projections, soffits and overhangs: (a.) Roof overhangs may be in the form of cantilevered planes projecting from a wall, or as an extension of the primary roof structure. The roof plane shall appear as a shallow plane of 12” or less in depth which may be sloped up to 4:12. (b.) Box soffits and mansard type facias are not permitted (see Figure 13.1.7-14) [Figure: Figure 13.1.7-14: Examples of permitted and non-permitted shading devices] [image omitted; see the official ordinance] [Figure text: Awning - permitted | Suspended metal awning - permitted | Gallery/arcade - permitted | Projecting roof - permitted | Mansard roof - not permitted | Box soffit - not permitted] g. Screening of Mechanical Equipment (i) Rooftop mechanical and electrical equipment must be screened from public view in all Sub-districts by a parapet wall, enclosed within roof volumes or other building elements designed as an integral part of the building. Screening elements must be at least as high as the equipment being screened. (ii) For buildings with no or low parapet walls, roof-mounted equipment must be screened on all sides by an solid screen compatible with the building’s texture, quality, material and color, or set back from the edge so that the mechanical equipment is not visible from the street. (iii) Ground-mounted mechanical and electrical equipment must not be installed between the building and the public sidewalk. Equipment that is located on the side of the building must be screened from view from the public sidewalk. (iv) Refer to UDC Section 5.3.2 Mechanical and Utility Equipment Screening for additional screening standards. h. Exterior Stairs (i) Exterior stairs visible along any Type ‘A’ or ‘B’ Frontages shall not be permitted. (ii) Exterior stairs that are used to access a building entry shall be constructed of durable materials which may include concrete, stone or brick. Handrails shall be of metal. (iii) Exterior, open stairs used to access the second floor of a building must not project in front of a façade plane that faces a public street or right-of-way. (iv) Open stairs on the side of a building visible from the public right-of-way must be enclosed with partial or full height walls, or shall be flush or recessed behind the façade plane. 3. Multi-Story Buildings Standards a. Intent: Large, multi-story buildings have a big impact on the character of a street and district. These standards are intended to minimize the impact of long, featureless facades and to ensure that the building produces a positive environment, especially along the public sidewalk and street. The following standards are applicable to all multi-story buildings (six stories or less) including multi-family, mixed-use, and commercial buildings. b. Building bulk and massing (i) Maximum building length: No building shall be greater than 250' in length (along any existing street frontage) without an unconnected physical separation of at least 15 feet between another building. The separation shall include a Paseo (Pedestrian Passage) with a Public Access Easement, allowing a walkable connection from block face to block face. (1) The pedestrian walkway shall be lighted and designed to be safe and visually interesting for pedestrians. (2) The pedestrian walkway shall be designed so that it cannot be closed or locked. (3) A street in compliance with Section 13.1.8 may be utilized in lieu of a paseo. (4) In cases where a Paseo (or street) passes through a development having common ownership, upper floors may bridge over the Paseo for a combined length not to exceed 25% of the paseo length. The covered portion of the Paseo shall have a clear ceiling height of at least 10 feet and not exceed 40 feet in depth for any one segment. (ii) Additional Minor Modifications to Maximum Building Length: In case of a building with three (3) or more street facing facades (includes facades along pedestrian paseos) that exceed the 15% blanket minor modification of maximum building length allowed, an additional modification may allow some building facades greater than 288' feet maximum length. In such cases at least half of the building facades shall meet the maximum building length of 250'. The other half may exceed 288 feet up to a maximum of 350 feet. c. Roofs (i) Roof forms may be of any type (flat, gable, hip, etc.) unless further regulated in the FBZD standards. (ii) A parapet wall must not extend more than six feet above the finish roof level. d. Façade Articulation (i) Facades of buildings exceeding 100 feet in length, shall be divided into multiple façade planes as shown in Figure 13.1.7-15. Façade Planes may, but are not required, to have a corresponding change in color and/or material. (ii) Façade Elements: Façade Elements are intended to provide visual interest, enhance the character of the street, and to create a more human scale to otherwise large buildings. Façade Elements are categorized as Basic Façade Elements (Base and Top) and Facade Enhancement Elements. Alternative methods of achieving the intent of these standards may be considered for approval by the Zoning Administrator through a Minor Modification. Façade Elements must be provided as indicated in Tables 13.1.7-15 through and 13.1.7-17. Table 13.1.7-15: Required Façade Articulation for Multi-Story Buildings [Figure: elevation view and partial plan view of façade planes] [image omitted; see the official ordinance] [Figure text: BUILDING LENGTH | Minimum 24” vertical height change between Facade Planes | ELEVATION VIEW SHOWING FACADE PLANES (Doors, windows and other fenestrations not shown) | BUILDING | PARTIAL PLAN VIEW | Minimum 24” horizontal break between Facade Planes] | LENGTH OF BUILDING | | | 100' OR LESS | 100'-200' | 200'-250' Min. Number of Façade Planes | 1 | 2 | 3 Max. Number of Façade Planes | 3 | 5 | 5 Table 13.1.7-16 Basic Façade Elements for Multi-Story Buildings. | BUILDING HEIGHT | | Required façade elements below: | 2 STORIES | 3 STORIES | 4 STORIES (and greater) Articulated Top | R | R | R Articulated Base | NR | R | R Min. # of Façade Enhancement Elements per Façade Plane (see Table 13.1.7-17) | NR | 1 | 2 R=Required, NR=Not Required Table 13.1.7-17: Façade Enhancement Elements This building elevation diagrams below illustrate the Façade Elements which are to be utilized to meet the requirements of Table 13.1.7-16. Required glazing is not shown in this diagram. BASIC FAÇADE ELEMENTS (see Table 13.1.7-16 where required) [Figure: building elevation diagram of articulated base and top] [image omitted; see the official ordinance] | Articulated Base: Provide a horizontal band at the base that starts at finish grade and extends at least 18 inches but no higher than the second story window sill. The band may be a wall projection of at least 1 inch or a change in wall material. Articulated Top: Provide a continuous horizontal band near the top between the upper story window head and the roof eave or the top of the parapet. Use projections or changes in material or color to emphasize the top of the building. The band must be at least 18 inches tall and include at least one element that projects 6 inches or more. ENHANCED FAÇADE ELEMENTS (see Table 13.1.7-16) for required number of façade elements) Note: For buildings with two or more façade planes, the façade enhancement elements may, but are not required to, change at each façade plane. [Figure: building elevation diagram of ground floor storefronts] [image omitted; see the official ordinance] | Ground floor storefronts: Storefront window and door openings on the ground floor must provide at least 60 percent clear glass area, measured under the fenestration standards in this section. [Figure: building elevation diagram of balconies] [image omitted; see the official ordinance] | Balconies: At least 50 percent of the residential units that face a Type ‘A’ street must have a balcony. Balconies may be projecting, recessed, or semi recessed, and each must provide a minimum clear floor area of 20 square feet. [Figure: building elevation diagram of articulated top story] [image omitted; see the official ordinance] | Articulated top story: a grouping of upper story windows having a minimum glazing percentage of 50% measured from the finish floor elevation to a height of ten feet, combined with a change in exterior wall color or material between the windows. This element may also count toward the requirement for a horizontal band element at the top of the building [Figure: building elevation diagram of porch or gallery] [image omitted; see the official ordinance] | Porch/Gallery: A continuous gallery for the length of the façade plane, or for residential uses, covered porches that comprise a minimum of 50% of the façade length. Note: this option may also contribute to the shading requirement (Section 13.1.7.D.2.f.). [Figure: building elevation diagram of suspended metal canopy] [image omitted; see the official ordinance] | Suspended metal canopy: a permanent metal canopy, extending the full length of the façade plan, and projecting a minimum of six feet. Note: this option may also contribute to the shade requirement (Section 13.1.7.D.2.f.). [Figure: building elevation diagram of increased transparency] [image omitted; see the official ordinance] | Increased transparency: Increase window and door openings to a minimum of 40% on all levels. 4. High-Rise Buildings: This section applies to portions of all buildings over 6 stories or 75 feet in height a. An additional building step back of 10 feet from the lower façade shall be required at the height of 75 feet along all Type ‘A’ Frontages. b. Balconies and other building elements may encroach into the building step back for no more than 50% of the step back area. c. Towers shall be set back a minimum of 30 feet from any adjoining property lines (other than street ROW). d. Incorporate terraces, step backs and height variations to articulate the top floor(s) of the tower. These areas can be used as amenities for residential and office uses and/or for private terraces. 5. One-Story Non-Residential Buildings: Facades of single-story non-residential buildings which face a public right-of-way, or public access easement shall comply with the design elements shown in Figure 13.1.7-18. Figure 13.1.7-18 One-story Non-Residential Building Design [Figure: plan view and elevation view of one-story non-residential building] [image omitted; see the official ordinance] [Figure text: PLAN VIEW | d (width to height ratio) | ELEVATION VIEW | (Letters correspond with standards in Section 13.1.7.D.5. below)] a. Building height: Minimum 20 feet to the top of the parapet wall, or minimum 16' to the eave of a sloped roof. b. Storefront windows: Minimum 8 feet to the top of the storefront window system. Refer to glazing standards for minimum glazing area. c. Doors to be commercial grade with minimum 30% glazing. d. Façade Planes that exceed a width to height ratio of 3:1 shall incorporate: (i) A change in façade plane with a minimum horizontal offset of 24” and (ii) A minimum change in roof or parapet height of 24”. e. Awnings and other shading devices shall be required as part of the Section 13.1.7.D.2.f. f. Integrate signage elements and method of attachment into façade design. g. Roofs shall be primarily “flat” with parapet walls to screen rooftop equipment. Up to 25% of the roof area may consist of sloped roof forms to accentuate entries and building features. 6. Civic and Religious buildings: Civic buildings are buildings that serve a public function such as libraries, schools, museums and community centers. Buildings designed for religious purposes can also be considered civic buildings because of their public interaction and prominence as landmarks. a. Architecture: The architecture of civic buildings should reflect their importance to the community by exemplifying high quality architecture and be situated on a block to reinforce their presence. b. Open Space: Civic buildings, such as religious buildings and theaters, which have many people arriving in a short period, should provide adequate open space near the primary entrance and sidewalk for informal gatherings before and after events. c. Scaled to context: Civic buildings located in the Traditional Neighborhood Sub-district can have a disruptive impact on neighborhoods due to traffic congestion and large parking lots. Civic Buildings should therefore be sized to fit within the context of the surrounding neighborhood. d. Applicable Standards: Civic Buildings that do not comply with the sub-district standards may request a Minor Modification if they meet the criteria established above. 7. Auto-oriented Sites Elements: This section applies to auto-oriented site elements such as drive through lanes, drive up lanes, service bays, and gas pump canopies are integral to the business’s operation and where allowed in Table of Allowed Uses 13.1.4.-1. a. Drive-throughs with single lanes operations and associated with restaurants, pharmacies and other retail uses shall be configured as shown in Table 13.1.7-19. b. Gas stations, bank drive-throughs, auto-service, and restaurants with multiple vehicular bays shall be configured as shown in Table 13.1.7-20. Table 13.1.7-19: Sites with Single-Lane Drive-Throughs [Figure: site plan of single-lane drive-through sites, numbered 1 to 5] [image omitted; see the official ordinance] 1 | Parking 2 | Principal Building – entry may be on the side of the building with a connection to the public sidewalk 3 | Extend public sidewalk building and entry. 4 | Drive-through lane 5 | Screen back-of-house equipment and utilities Table 13.1.7-20: Sites with Multiple Vehicuar Bays [Figure: site plan of multiple-bay sites, numbered 1 to 5] [image omitted; see the official ordinance] 1 | Parking 2 | Principal building – entry may be on the side of the building with a connection to the public sidewalk 3 | Extend public sidewalk building and entry. 4 | Place canopies and vehicular bays behind the primary building 5 | Screen back-of-house equipment and utilities 8. Multi-Level Parking Garages: Multi-level parking garages must be designed as a cohesive extension of the main building’s façade and with a focus on reducing the visibility of parked vehicles from the exterior. a. All levels will have active uses (i.e., commercial, retail, residential) for a depth of at least 20 feet along designated Type ‘A’ Frontages. The length of the active use shall be at least equal to the minimum Frontage Build-out requirement. All other frontages may be screened to create a harmonious and visually appealing streetscape. b. The materials used for the exterior surface of parking garages must adhere to the same standards as those for exterior building walls and should visually complement the main structure. c. Facades along all public street frontages must feature openings, either glazed or unglazed, on every level. These openings should meet or exceed the minimum transparency (window and door openings) percentage specified in Table 13.1.7-10. d. Where a parking structure is located at the perimeter of a building, it should be screened on all floors in such a way that cars on all parking levels are completely screened from view (see Figures 13.1.7-21 and 13.1.7-22). Required guardrails at the building perimeter shall be constructed of opaque, solid materials to screen vehicle headlights. e. Architectural screens shall be used to articulate the façade, hide parked vehicles, and shield lighting. f. All exterior lighting must be angled downwards and should be designed to reduce glare onto adjacent public right of ways and residential areas. g. Ramps within parking garages should not be visible from Type ‘A’ Frontages and must not be situated along the outer edges of the structure facing these frontages. In cases where ramps are allowed on an external wall along Type ‘B’ Frontages, they must be screened to lessen their visual impact. [Figure: Figure 13.1.7-21 In the above example, the parking levels are fully exposed and do not provide an acceptable level of screening.] [image omitted; see the official ordinance] [Figure: Figure 13.1.7-22 In the above example, the garage levels are screened from view and incorporated with the building’s façade architecture. The example also incorporates commercial space on the ground level.] [image omitted; see the official ordinance] E. Special Requirements in the Regulating Plan 1. Terminated Vistas a. The Regulating Plan may recommend locations for terminated vistas. These typically occur where a street terminates at a ‘T’ intersection, providing an opportunity to create an interesting focal point at the end of the street (see Figures 13.1.7-23 and 13.1.7-24). At these locations, use architectural features to provide visual interest and focus on the terminated vista. This may include projecting a portion of the building forward or backward, and/or altering the roof shape or height. Any raised portions shall not exceed the allowable height limit of the district. [Figure: Figure 13.1.7-23 Diagram highlighting the terminated vista at the end of a street.] [image omitted; see the official ordinance] [Figure: Figure 13.1.7-24 Example of a terminated vista on a shopping street.] [image omitted; see the official ordinance] 2. Ground Floor Commercial-Ready Requirements: a. Ground floors of all buildings which are identified on the Regulating Plan as requiring Commercial-Ready Ground Floor construction; or are seeking a Residential Bonus Density per FBZD standards, must be designed and built to accommodate, at a minimum, Business Occupancy and/or Mercantile Occupancy groups as defined by the Building Code. In addition, the following standards shall apply (See Figure 13.1.7-25): (i) A building entrance that opens directly onto the sidewalk along the Type ‘A’ Frontage and meeting the standards in Section 13.1.8.C. General Street and Sidewalk Design Standards; (ii) A minimum structural ceiling height of 12 feet; and (iii) Minimum leasable depth that is 20 feet from the front facade that meets the transparency requirements for non-residential use in this Section. [Figure: Figure 13.1.7-25 Illustration showing application of Commercial Ready Frontage Requirements] [image omitted; see the official ordinance] [Figure text: Bottom of Structural Members | Finished Floor | 12' Min. Height | 20' Min. Depth | 25' Min. Width | Sidewalk | Entrance opens directly onto to the sidewalk | Spaces at the front of a building located along a commercial ready frontage must be designed to accomodate future commercial uses. (No structured parking is allowed).] 13.1.8. Street & Sidewalk Standards A. Purpose and Intent The section is intended to provide standards that will enhance mobility options throughout the district, resulting in a more walkable and connected community. This section includes standards for sidewalks along existing streets, new streets intended to enhance connectivity, and pedestrian connections on private property to facilitate access from public streets and sidewalks. In addition to meeting the purpose and intent in Section 5.91. of the UDC, mobility infrastructure in FBZ shall emphasize pedestrian connectivity by creating or maintaining a compact block structure, and a network of connected streets and sidewalks that balance different modes of transportation. This section is organized as follows: 1. Administration of the Street and Sidewalk Standards 2. General Street and Sidewalk Design Standards. 3. Standards for Sidewalks Along Existing Streets: Property owners/developers may be required to provide new public sidewalks along existing roadways that front their property where there are no existing sidewalks, or where sidewalks are determined to be deficient. 4. Standards for New Streets, Pedestrian Connections and Accessways. This section has standards for new streets and sidewalks to be located on large parcels and undeveloped areas that are intended to become part of the publicly accessible street network. The FBZD Regulating Plan shall identify the general alignment of these new transportation elements. B. Administration of the Street and Sidewalk Standards 1. On-Site Pedestrian Walkways: Sidewalks internal to a development site to connect building entrances to the public sidewalks shall be provided as required in UDC Sections 5.9.4.B and 5.9.4.C Multi-Family Residential and Nonresidential Pedestrian Connections. 2. Role of the Regulating Plan a. Each FBZD Regulating Plan shall establish the required street network which includes new streets, public pedestrian connections, trails and other components of a complete transportation and mobility network. b. Alignment shall follow the Regulating Plan, and any development that does not meet the alignment for new streets indicated in the Regulating Plan shall identify deviations from the alignment along with justification for the proposed change and how the adjusted alignment is expected to meet the intent of the street network as shown in the Regulating Plan and adherence to block standards. c. Components of the Street Network in the Regulating Plan: The Regulating Plan includes the following elements: (i) Required/Existing Streets – these are mainly existing, improved or new streets that are needed to implement the ultimate street network envisioned in the FBZD Regulating Plan. They shall be mandatory at the time of redevelopment including the requirement to dedicate right-of-way in conformance with UDC Article 6. The alignment of new Required Streets may be adjusted with approval of Minor Modifications. (ii) Recommended Future Streets – these are new streets that indicate the likely locations for new streets and blocks. If a Future Street as indicated in the Regulating Plan is implemented through right-of-way dedication or reservation per UDC Article 6, the development shall be exempt from the block standards in Section 13.1.8.C below. Future Streets may be substituted by pedestrian passages, paseos, alleys, or accessways based on the specific context. (iii) Accessways and Alleys: (1) Where existing alleys are established, maintaining the right-of-way/easement and utilization of cross access between properties for service and parking access shall be required to the extent feasible and with the approval of the City’s Public Works and Engineering Department. (2) When a large development is platted or replatted with new streets and lots, incorporating cross access easements or private streets to access mid-block lots, for both commercial and residential uses shall be required. 3. Project Circulation Plans All development sites on property that encompasses two (2) cumulative acres or greater and/or request a density bonus under any FBZD standards must provide a Project Circulation Plan prior to or in conjunction with a site plan or preliminary plat application for the development. a. A Project Circulation Plan must demonstrate the following: (i) Adherence with standards for new sidewalks along existing streets; (ii) Adherence with standards for on-site pedestrian connections with Public Sidewalks; (iii) New Street and block layouts’ adherence to the FBZD Regulating Plan’s connectivity goals, and any justified modifications; and (iv) Street design’s compliance with Section 13.1.8.E. and any FBZD street standards. b. Project Circulation Plans shall be approved by the Administrator based upon input from the City of Arlington Public Works and/or City Engineer. c. Project Circulation Plans may be submitted with Traffic Impact Statements as required by the city’s Design Criteria Manual as adopted. 4. Access Easements and ROW dedication To enhance walkability and improve vehicular circulation, easements and ROW dedications may be needed to accommodate mobility components. a. New Streets, Pedestrian Connections and trails are intended to be publicly accessible. Public accessibility may be accommodated through the dedication of city-owned Right-of-Way, or through a public access easement (for pedestrian connections and trails). The ROW dedication may include the travel lanes and extend to the outside edge of the sidewalk clear zone as indicated in street sections. b. New streets shall be reviewed by the City and shall follow standards in this Section, the City of Arlington’s most recently adopted Thoroughfare Development Plan and Design Criteria Manual. c. New or improved sidewalks along existing streets: where existing ROWs are insufficient to accommodate the sidewalk design as shown in this section, a public access easement shall be required which may include the Sidewalk Clear Zone and Furnishing Zone as required by this section. Maintenance of all sidewalks located within public access easements shall be the responsibility of the property owners abutting such sidewalks. d. Accessways: The Regulating Plan indicates recommended accessways to facilitate circulation at the rear of the property and between adjacent properties or developments. Access easements between properties shall be required at the time of redevelopment to reduce traffic impact and minimize curb cuts on collectors and arterials unless grade changes and existing site configurations make cross access impractical. 5. Street Cross Sections This section includes schematic street and sidewalk sections which identify the minimal design metrics and design elements to produce comfortable and safe vehicular and pedestrian facilities. a. Street cross sections may be adjusted by the City to accommodate existing conditions, including utility easements, grade changes, fire access, existing improvements, and other physical constraints. b. Accommodation of pedestrian access and comfort including the Furnishing Zone and Sidewalk Clear Zone should be prioritized when considering any modifications to the cross sections in the FBZs. C. General Street and Sidewalk Design Standards 1. Block Standards: In order to implement a compact and walkable street network, new streets and pedestrian ways are used to divide large areas into smaller city blocks. The FBZD Regulating Plan establishes the block structure for large areas and properties that are anticipated to be developed or redeveloped. Private streets with adjacent sidewalks that are accessible through a public use easement, or a private walkway, which is accessible through such public use easement, may serve as a block boundary. When there are proposed deviations from the Regulating Plan, or when there is a site subject to the Project Circulation Plan in Section 13.1.8.B.3, the following standards shall be used to establish the block structure: a. Maximum block perimeter for new blocks shall be 1,320 feet. b. The maximum length of a block on any one side shall be 320 feet. c. New blocks may be defined by new streets, existing streets, private streets with public access easements or publicly-accessible pedestrian connections between two perpendicular or adjoining streets. d. At least 2 block edges must have vehicular street frontage. e. Greater block perimeter, spanning of existing streets, and any existing street vacations may only be considered with approval of a Project Circulation Plan. 2. General Sidewalk Design Standards a. Continuity of Sidewalks: All sidewalk elements (public and internal sidewalks) shall be connected and continuous to the greatest extent possible, however, the sidewalk may be interrupted by perpendicular crossing of parking lot aisles (but not parking spaces). (i) Materials selected for paving shall be of durable quality and require minimal maintenance and shall be approved by the City of Arlington. (ii) Utilities and associated easements that conflict with the requirements for the sidewalk should be identified early so that modifications to the design can be made while still meeting the intent of these standards. (iii) Building Entrance Elevations: Entrances to buildings meant for public access, facing a public street and sidewalk, must be at an elevation that permits direct entry without external ramps and railings, especially in the Core Sub-district. Any required ramps due to elevation changes should be incorporated within the building’s interior. Civic buildings are exempt from this requirement. b. Sidewalk Sub-zones: A high-quality pedestrian environment typically consists of the following sub-zones as described here and as illustrated in Fig. 13.1.8-1. (i) Sidewalk Clear Zone (SW): Shall be an area paved with concrete or other approved material and shall comply with ADA and Texas Accessibility Standards and must be unobstructed within the required minimum sidewalk width as indicated in Section 13.1.8.D. and a minimum vertical clearance of eight (8) feet. Accessibility is required to connect sidewalk clear zones on adjacent sites and lots. (ii) Frontage Zone (FR): Is the portion of the private lot that is located between the sidewalk clear zone and the building facade intended for control and use by the building owner and/or tenant. The encroachment zone may accommodate out-swinging entrance doors, outdoor dining, portable signs, shade structures, or landscaping. (iii) Furnishing Zone (FZ): The area between the sidewalk clear zone and the curb or vehicular lane. The sidewalk furnishing zone is intended for the placement of street trees and street furniture including seating, pedestrian lighting, waste receptacles, fire hydrants, traffic signs, newspaper vending boxes, two-wheeler or bicycle racks, public utility equipment such as electric transformers and water meters, and similar elements in a manner that does not obstruct pedestrian access or motorist visibility. Additional standards apply to the sidewalk furnishing zone as follows: (1) Where no on-street parking is present to protect pedestrians, the sidewalk furnishing zone should be primarily landscaped with grass or low ground cover and street trees as required. (2) Where protected by on-street parking, the sidewalk furnishing zone may be paved to match the sidewalk, interrupted by tree wells or planters to correspond with street tree locations. [Figure: Figure 13.1.8-1 Sub-Zones of the Sidewalk] [image omitted; see the official ordinance] c. Street Tree Standards: (i) Street trees shall be planted along all public and private streets within the sidewalk Furnishing Zone with a minimum distance of 3’ from the centerline of the trunk to the face of curb. (ii) Street trees shall be a minimum of three (3) inch caliper. (iii) Spacing shall be coordinated with pedestrian lighting and tree species as shown in Table 13.1.8-2. Where necessary, spacing exceptions may be made to accommodate mature trees, curb cuts, fire hydrants and other infrastructure elements through the Minor Modification process. (iv) To maximize survival rates, trees shall be planted to ensure proper drainage and shall be irrigated. Each tree shall be planted in a planting area no less than 36 square feet. Trees planted adjacent to the street will require a vertical root barrier along the curb and sidewalks. d. Low maintenance tree planter systems, such as pervious pavers or planting strips, shall be used. Tree grates collect trash and damage trees and are not a low maintenance system. e. Street tree species shall be selected from the City Approved Planting List maintained by the Zoning Administrator. Table 13.1.8-2 Street Tree Requirements [Figure: TYPICAL TREE / PEDESTRIAN STREETLAMP SPACING] [image omitted; see the official ordinance] TREE SPACING (minimum center to center) 15 FEET (Small Canopy) | 25 FEET (Medium Canopy) | 35 FEET (Large Canopy) 3. Pedestrian lighting: New development shall provide pedestrian lights within the sidewalk’s Furnishing Zone. a. Pedestrian lights shall be located approximately at the midpoint between two trees and spaced a maximum of 75 feet apart and approximately 4 feet behind the face of curb or as approved by the City, and in accordance with Oncor’s requirements. Where necessary, spacing exceptions may be made to accommodate mature trees, curb cuts, fire hydrants and other infrastructure elements. b. Pedestrian lighting shall be certified by DarkSky International. c. Pedestrian lighting shall be no taller than sixteen (16) feet. However, pedestrian lights may share a support pole with street lighting which may be at a higher level. d. Specific lamp and post standards may be established for different areas through a unified Streetscape Design Manual. D. Standards for Sidewalks on Existing Streets New development or redevelopment shall include enhancements to the public sidewalk and streetscape along existing streets where there are no sidewalks or existing sidewalks are substandard. 1. A new development or redevelopment shall provide new sidewalks or improved sidewalks that meet these standards. 2. Based on the existing street context, the Zoning Administrator may approve minor modifications to: a. Waive the sidewalk requirement; or b. Reduce sidewalk dimensional standards in order to facilitate implementation. 3. Unless otherwise waived, sidewalks shall be provided along existing streets according to Table 13.1.8-3 and sidewalk sections which follow (Tables 13.1.8-4 and 13.1.8-5). TABLE 13.1.8-3: Sidewalk Types by Street Type & Sub-District STREET TYPE COMPATABILITY BY SUB-DISTRICT STREET TYPE (BELOW) | TRADITIONAL NEIGHBORHOOD (TN) | URBAN NEIGHBORHOOD (UN) | CORRIDOR MIXED-USE | CORE MIXED USE STREET | N/A | Urban Sidewalk Type 1 or 2 | Urban Sidewalk Type 1 or 2 | Urban Sidewalk Type 1 or 2 NEIGHBORHOOD STREET | Neighborhood Sidewalk | Urban Sidewalk Type 1 or 2 | Urban Sidewalk Type 1 or 2 | Urban Sidewalk Type 1 or 2 URBAN ARTERIAL | Sidewalks for urban arterials shall be as identified in the FBZD standards for specific corridors and/or as required in the city’s Thoroughfare Development Plan or Design Criteria Manual SHARED STREET | Shared streets are intended to be implemented under a city-initiated capital improvement project or with City Council approved Development Agreement. Table 13.1.8-4: Urban Sidewalks Urban Sidewalk Type 1 is the preferred sidewalk design contingent upon adequate ROW. Urban Sidewalk Type 2 may be used when ROW is limited. [Figure: URBAN SIDEWALK – TYPE 1] [image omitted; see the official ordinance] URBAN SIDEWALK – TYPE 1 TL | Travel Lanes (existing) PK | Parking – 8’ (min.) (on-street parking is optional; angled or head in parking may be permitted with a Minor Modification) FZ | Furnishing Zone – 6’ Min. SW | Sidewalk Clear Zone: • Core Sub-district: 10’ minimum • UN Sub-district: 8’ minimum • CMU Sub-district: 6’ minimum FR | Frontage Zone: Varies by Sub-district and ground floor use [Figure: URBAN SIDEWALK – TYPE 2] [image omitted; see the official ordinance] URBAN SIDEWALK – TYPE 2 TL | Travel Lanes (existing) PK/TR | Parking – Max. 2 spaces between tree planters (Angled or head in parking may be permitted with a Minor Modification) BF | Buffer with pedestrian lighting (min. 2’) SW | Sidewalk Clear Zone: • Core Sub-district: 10’ minimum • UN Sub-district: 8’ minimum • CMU Sub-district: 6’ minimum FR | Frontage Zone: Varies by Sub-district and ground floor use Table 13.1.8-5: Neighborhood Sidewalk [Figure: Neighborhood Sidewalk plan and section view diagram] [image omitted; see the official ordinance] TL | Travel Lanes (existing) PK | Parking: 8’ (min.) (optional – parallel only) FZ | Furnishing Zone: 6’ Min., Grass with street trees and pedestrian lighting SW | Sidewalk Clear Zone: 6’ Min. FR | Front Yard E. Street Typology and Cross Sections New or improved streets in all FBZDs shall be designed with pedestrian comfort and safety in mind and shall be based on the Street Typology Classification and associated cross sections established in this section. Cross sections and alignments may be adjusted with approval of a Minor Modification and/or a Project Circulation Plan based on the requirements in Section 13.1.8.B. 1. Street Typology Classifications Street Typology establishes standards for the actual cross-section of the street itself and/or the sidewalk standards for existing streets. It typically addresses the allocation of space within the public right-of-way and its emphasis towards different modes of transportation –automobile, two-wheeler and bicycle, or pedestrian. The following Street Types are established under FBZ-GS. Additional street types may be established in different FBZDs. a. Urban Arterial: This street design aims to balance vehicular traffic and encourage pedestrian activity by reducing traffic speeds through various measures such as pedestrian volume, street layout, landscaping, lighting, and special material choices to influence driver behavior and enhance multimodal use of the corridor. Standards for Urban Arterials are established in the city’s most recently adopted Thoroughfare Development Plan and Design Criteria Manual. b. Mixed-Use Street: The goal of a mixed-use street is a general street that is versatile to address a variety of conditions in FBZDs. They effectively balance vehicular traffic while encouraging pedestrian activity and supporting commercial and residential needs (see Tables 13.1.8-6 and 13.1.8-7). c. Neighborhood Street: This street is designed for predominantly residential areas and features a parkway with street trees, sidewalks and substantial setbacks from the street ROW (see Table 13.1.8-8). d. Shared Street: This is a roadway that is designed for shared use by pedestrians, cyclists, and motorists, often characterized by slow travel speeds and pedestrian priority. Emphasis is placed on the flexible use of the right-of-way to ensure that vehicles, pedestrians, two-wheelers, and bicycles can coexist harmoniously (see Table 13.1.8-9). 2. Other mobility elements: a. Pedestrian Connections: Where a Pedestrian Connection is shown on the Regulating Plan, the requirement may be accommodated as follows: (i) Paseo (Pedestrian Passage) as shown in Table 13.1.8-10, or; (ii) Mixed-Use Street may be utilized in the UN, CMU and CORE Sub-districts. (iii) Neighborhood Street may be utilized in the TN Sub-district. b. Accessways: Where recommended on the Regulating Plan, provide accessways as shown in Table 13.1.8-11 to facilitate vehicular and service access at the rear of the property. 3. The following tables include schematic street sections and design criteria for each street type and mobility element indicated above. Table 13.1.8-6: Mixed-Use Street – Type 1 [Figure: MIXED-USE STREET – TYPE 1] [image omitted; see the official ordinance] Description: A two-way street with parallel parking both sides, and wide sidewalks intended for heavy pedestrian usage. The furnishing zone accommodates street trees, seating, bike racks and other sidewalk amenities. ROW | 70 feet, minimum TL | Travel Lanes – 11’ PK | Parking, 8 feet (parallel parking), or optional angled or head-in parking with Minor Modification FZ | Furnishing Zone – Min. 6 feet SW | • Core Sub-district: 10’ minimum • UN Sub-district: 8’ minimum • CMU Sub-district: 6’ minimum FR | Frontage Zone: Commercial ground– floor use – Min. 2’ Residential ground– floor use – Min. 5’ Table 13.1.8–7: Mixed-Use Street – Type 2 [Figure: MIXED-USE STREET-TYPE 2] [image omitted; see the official ordinance] Description: A two-way street with parallel parking on both sides. Trees are positioned between every one or two parking spaces. Mixed-Use Street -Type 2 may be used as an alternative to this street design when ROW is insufficient for a Mixed-Use Street -Type 1. ROW | 58 feet minimum TL | Travel Lanes – 10’-11’ (10’ preferred) PK/TR | Parking / Tree Planters: Min. 8 feet, max. two parking spaces between tree planters. FZ | Furnishing Zone – Min. 2 feet to accommodate pedestrian lighting poles SW | • Core Sub-district: 10’ minimum • UN Sub-district: 8’ minimum • CMU Sub-district: 6’ minimum FR | Frontage Zone: Commercial ground– floor use – Min. 2’ Residential ground– floor use – Min. 5’ Table 13.1.8-8: Neighborhood Street [Figure: NEIGBORHOOD STREET] [image omitted; see the official ordinance] Description: A two-way street with parallel parking on one or both sides and tree-lined sidewalks. Intended for new local streets in predominantly residential areas. TL | Travel Lanes – 10’-11’ (10’ preferred) PK | Parallel parking on one or both sides (optional) FZ | Furnishing Zone – Min. 6 feet, grass with street trees and pedestrian lighting SW | Sidewalk – 6’ Min. FR | Frontage Zone: corresponds to Front Yard Table 13.1.8-9: Shared Street [Figure: SHARED STREET] [image omitted; see the official ordinance] Description: A street designed to prioritize pedestrian and bikes while also accommodating slow vehicular traffic. Curbs are flush with sidewalk level and paving is textured or patterned. Intended for streets with low traffic volumes. Shared Streets can be closed for special activities and public events and act as linear plazas. ROW | 52’ minimum TL | Travel Lanes – 11’ (min.) FZ/PK | Furnishing Zone / Parking: 8 feet minimum; this zone accommodates street trees, lighting, seating, outdoor dining and intermittent parallel parking. No more than 2 parking spaces between trees. SW | Sidewalk – 8’ Min. FR | Frontage Zone: Commercial Use - Min. 2’ Residential Use - Min. 5’ Table 13.1.8-10: Paseo (Pedestrian Passage) [Figure: PASEO (PEDESTRIAN PASSAGE)] [image omitted; see the official ordinance] Description: A pedestrian-only passage with a public access easement intended to facilitate pedestrian connections between streets. PAE | Public Access Easement; Minimum 20 feet SW | Clear Sidewalk – Minimum 8 feet FZ | Furnishing Zone – Min. 6 feet, may be paved or landscaped with street trees and pedestrian lighting FR | Frontage Zone: Commercial Use - Min. 2’ Residential Use - Min. 5’ Table 13.1.8-11: Accessway [Figure: ACCESSWAY] [image omitted; see the official ordinance] Description: A cross-access easement intended to facilitate service and parking access between properties and toward the rear of the property (behind the building). Recommended Accessways are identified on the Regulating Plan. This may be established with a cross access easement or a private street or an existing/improved public alley. AE/TL | Access Easement / Travel Lanes – Min. 20’ (may be wider if it is also a fire lane) SB | Building Setback – 5’ min. PK | Parking may be accessed directly from the Access Way 13.1.9. Parking, Screening and Landscaping A. Parking 1. Off-Street Parking: All development shall meet the off-street parking standards in this section. Parking requirements in this section may be amended with future FBZDs at the time of rezoning. Table 13.1.9-1: Required Amount of Off-Street Parking Sub-districts | Core | All other Sub-districts | Additional Criteria Land Use | Min. Off-Street Vehicular Parking Requirement All Non-Residential uses (other than listed below) | 1.0 space per 400 sq.ft. of GFA; | 1 space per 300 sq.ft. of building area | 1. An off-site parking or shared parking plan may be approved as established in UDC Section 5.4.7.C. 2. The first 2,000 sq.ft. of any non-residential use in a building shall be exempt from the parking calculation. 3. If a proposed development makes improvements to any substandard streets by meeting the standards in Section 13.1.8.D, then any newly created on-street parking may count towards a maximum of 25% of the required off-street parking for any ground-floor commercial ready square footage ONLY. 4. ADU: 1 space per unit Assembly uses | 1.0 space per every 8 seats | 1.0 space per every 6 seats Lodging uses (Hotels and Motels, Lodging Houses, Private Dorms) | 0.5 space per guest room; all other areas shall be parked at the non-residential rate above | 0.75 space per guest room; all other areas shall be parked at the non-residential rate above Residential uses | 1.0 spaces per each dwelling unit | TN Sub-district: 2.0 spaces per dwelling unit UN, CMU, SD Sub-districts: 1.5 spaces per each dwelling unit Group Living and Institutional uses | 1 per each four (4) beds in the facility | 1 per each four (4) beds in the facility Min. Two-Wheeler (Bicycles and Scooters) Parking Requirement All uses | 1.0 per every 5,000 sq.ft. of GFA | 5% of all provided automobile spaces | Location of Two-Wheeler Parking: For retail and commercial ready buildings, refer to the Streetscape Design Manual for details about placement of two-wheeler parking within the street furnishing zone. 2. Design of Off-Street Surface Parking Facilities: Only UDC Sections 5.4.9.A and 5.4.9.C. shall apply. 3. Design of On-street Parking: Standards in Section 13.1.8 shall apply based on the recommended cross section of the street frontage. Angled and head-in parking may only be approved with the approval of a Minor Modification based on the location of such proposed improvements and consistency of pedestrian facilities along the block and available ROW. 4. Remote Parking: Required vehicle parking must be located on the same lot as the use they are intended to serve. However, exceptions are permitted under the following conditions: a. Off-Site Parking Proximity: Parking spaces, except for those designated for accessibility, may be situated off the property but must be within 500 feet of the property they serve. b. Extended Distance Allowance: A maximum of 50% of the required parking spaces are permitted to be located beyond the 500-foot proximity limit, provided they are within 1,000 feet of the property served. c. Measurement of Distance: The distance to the off-site parking location should be measured as the walking distance along sidewalks or streets from the closest point of the parking area to property line of the property served. d. Parking Agreement: All off-site parking facilities must be backed by a remote parking agreement on form approved by the City, which should be included with the site plan application. e. Wayfinding and Signage: Any remote parking allowed under this section may require additional wayfinding signs and lighting to provide convenient access between the business and the remote parking lot based on the recommendation of the Zoning Administrator. 5. Off-Street Parking Location: a. Shall be established in Section 13.1.6 (C, CMU, and UN) and Section 13.1.7 (TN). b. Screening and design of parking structures: shall be established in Section 13.1.7 Building Design Standards. c. Parking lot screening shall meet standards in UDC Section 5.2.2.D . 6. Driveways and Access a. When a lot has access to a useable alley, public or private, new driveways shall not be permitted. The Zoning Administrator shall determine the accessibility of an alley. b. Curb cuts along Type ‘A’ Frontage streets are discouraged unless there is no platted or improved alley or shared access driveway. c. All streets shall meet the driveway spacing and design standards in the City of Arlington Access Management Standards, as amended unless the standards in this section are more restrictive in which case the more restrictive standard shall prevail. d. All TxDOT streets shall meet the state’s driveway spacing and permit requirements. B. Screening The purpose of this section is to ensure that utility and service areas are discreetly integrated into the site, particularly away from Type ‘A’ Frontages, where they should be least visible. These areas must be situated at the side or back of the main structures. 1. Service Areas: a. Loading/unloading areas shall be located along the lowest street frontage (Type ‘C’ or ‘B’ frontages only). b. Trash and recycling collection and other similar service areas must be located to the rear of buildings. c. Service areas (dumpsters) must be screened on 3 sides by a masonry wall a minimum 6 feet in height or to the top of the equipment, whichever is higher up to 8 feet maximum and on the 4th side by a solid gate at a minimum of 6 feet in height. d. The gate and wall must be maintained in good working order and must remain closed except when trash pick-ups occur. e. Trash and recycling collection and other similar service areas must be located on a concrete pad. [Figure: Figure 13.1.9-2 Image of appropriate dumpster screening and gate] [image omitted; see the official ordinance] 2. Wall-Mounted Equipment a. Wall-mounted equipment, not including antennas, must be located on non street-facing building facades or structures. b. Wall-mounted equipment, not including antennas, located on a building facade or structure that is visible from a private or public street (not including an alley) must be fully screened by landscaping or an opaque wall or fence that is compatible with the principal building in terms of texture, quality, material and color. c. Screening must be of a height equal to the height of the mechanical equipment being screened. 3. Ground-Mounted Equipment a. Ground mounted mechanical equipment includes, but is not limited to, utility meters, junction boxes, HVAC equipment, etc. b. Ground-mounted mechanical equipment must be located to the rear of buildings. c. Ground-mounted mechanical equipment above 30 inches in height that is visible from a public street (not including an alley) must be fully screened by landscaping or an opaque wall or fence that is compatible with the principal building in terms of texture, quality, material and color. d. Screening must be of a height equal to or greater than the height of the mechanical equipment being screened. 4. Roof-Mounted Equipment (refer to Section 13.1.7, Building Design Standards) 5. Screening Walls In addition to height transitions in Section 13.1.6, any new development within any FBZD that borders a single-family residentially zoned lot not located within the FBZD, the construction of screening walls is mandatory. The following standards must be followed: a. Material Quality: Walls must be built using high quality materials. Acceptable materials include decorative blocks, brick, stone, cast-stone, split-faced block, stucco applied over standard concrete masonry units, glass block, or any other material approved by the Administrator. b. Location: These walls are required to be positioned directly on the property line that separates the FBZD from the neighboring single-family zoned property. c. Easement Restrictions: The placement of walls within any designated easement is prohibited. d. Wall Continuity: The length of any uninterrupted stretch of wall or fence should not exceed 50 feet. To break the monotony, provisions such as columns, green spaces, transparent segments, or a variation in the construction material must be incorporated. e. Height Regulations: The wall’s height must be maintained between 6 and 8 feet, measured from the grade of the subject property to its tallest point. 6. Fences Fences in the front, side, and rear yards are permitted. Fences, when provided shall meet the following: a. Must be constructed of high-quality materials including; wood, wrought iron; composite fencing; aluminum; metal; or other material approved by the Administrator. b. Chain link fences are prohibited c. Height shall be no more than 4 feet. d. Front yard fences must be at least 50% open. C. Landscaping 1. Parking Lot Landscaping: All new and expanded off-street parking lots in the FBZD shall meet the Parking Lot Landscaping and Screening standards in Section 5.2.2.D. 2. Residential Lot Landscaping (on lots with 1 – 4 units): a. Either one street tree or one canopy tree in the front yard for every 25’ of lot width; and b. At least 15 percent of the front yard shall be landscaped with vegetative cover (trees, shrubs, ground covers, or ornamental grasses) other than turf grass. 3. Street Trees: Street tree planting requirements shall be established in Section 13.1.8.C. 13.1.10. Open Space Standards A. Intent Open space in walkable, mixed uses districts are a way to activate development, provide small spaces for both active and passive uses and ensure that open spaces are key to the goal of placemaking in FBZDs. In this context, the design, quantity and quality of open spaces are different from open spaces in other zoning districts. This section shall establish Open Space standards for all FBZDs in Arlington. B. Standard All multi-family and mixed-use development over 20,000 sq.ft. shall provide at least 5% of the gross site area as open space. 1. No less than 60% of the required open space shall be allocated to Common Open Space as identified in Table 5.10-A of the UDC. Areas not credited shall be as established in Section 5.10.3.C. 2. UDC Section 5.10.3.C. General Design Standards for Common Open Space shall apply to open spaces in FBZDs. 3. UDC Section 5.10.3.D. Use of Common Open Space shall apply with a 60% usability requirement in FBZDs. 4. UDC Section 5.10.3.E. Ownership shall apply to Open Spaces in FBZDs. 5. The remaining 40% of the required open space may be allocated to “common” or “private” open space (such as balconies, patios, or private yards). 13.1.11. Signage Standards A. Intent 1. To establish specific standards for all FBZDs for business identification. 2. To encourage creative and innovative approaches to regulating signs consistent with the principles and general intent of encouraging mixed-use in FBZDs. B. Principles 1. To encourage excellence in signage, both as a communication tool and as an art form. 2. To enhance the economic value of the built environment by avoiding visual clutter, which is potentially harmful to property values and business opportunities. 3. To allow and encourage creative and unique sign designs while preventing cluttered and unattractive streetscapes. 4. To ensure signs reinforce the walkable nature and are complementary to the Commercial Corridor redevelopment vision. C. Applicability The requirements of Article 7 Sign Standards of the City of Arlington UDC apply, except as listed below: 1. Types of Signs permitted shall be as established in Table 13.1.11-1 below 2. Signs prohibited in Section 7.4.1 shall also be prohibited in the FBZDs. 3. Signs in the FBZDs shall also meet all the General Provisions in Section 7.6. D. Minor Modifications Staff may authorize installation of a sign that exceeds the applicable size or height restriction by up to 10 percent of the maximum size or height prescribed by this section after determining that: 1. The applicant or user has demonstrated the existence of practical difficulties in complying with the standards. 2. A unique circumstance exists that make compliance with the requirements of this section impractical. 3. The sign is consistent with the general intent and principles of the sign standards of FBZD. E. Alternative Approval Process Signage that does not fit the specific standards and guidelines of this section may be considered for an administratively approved Alternative Equivalent Compliance (AEC) process or through an Alternate Sign Plan (ASP) approved by the City Council using the as established in Section 7.3.6 of the UDC. F. Sign Types Allowed by District Signs are allowed by Sub-district as set below. Specific requirements for each sign type are established in Article 7. Sign Standards of the UDC. Additional sign types may be permitted for special Sub-districts approved in area-specific FBZDs. TABLE 13.1.11-1 SIGN TYPE PERMITTED BY SUB-DISTRICT Sub-district → Sign Type | Core | CMU | UN | TN | Standards PERMANENT SIGNS Ground Signs (up to two tenants per sign) | | P | | | Section 7.8.2 Wall Signs | P | P | P | | Section 7.8.4 Projecting Signs (Blade) | P | P | P | | Section 7.8.5 Marquee Signs | P | P | | | Section 7.8.6 Building Identification Signs | P | P | P | | Section 7.8.7 Entryway Signs | | | P | | Section 7.8.8 Awning Signs | P | P | P | | Section 7.8.9 Canopy/Fascia Signs | P | P | P | | Section 7.8.10 Hanging Signs (Under-Canopy) | P | P | P | | Section 7.8.11 Window Signs | P | P | P | | Section 7.8.12 Directional Signs | P | P | P | | Section 7.8.13 Menu Board Signs – Drive-through | | P | | | Section 7.8.14-A:1 Menu Board Signs – Pedestrian Oriented | P | P | P | | Section 7.8.14-A:2 Building Directory Signs | P | P | P | | Section 7.8.16 Wall Murals | | | | | Shall be established in the specific FBZD regulations. See Section 7.8.17 Vertical Banners | P | P | P | P | Section 7.8.18 TEMPORARY SIGNS Residential Front Yard Signs | | | P | P | Section 7.10.1 Model Home Signs | P | P | P | P | Section 7.10.1 Real Estate Signs | P | P | P | P | Section 7.10.1 Banner Signs | P | P | P | | Section 7.10.1 Grand Opening Signs | P | P | P | | Section 7.10.1 Development Signs | P | P | P | P | Section 7.10.1 Sandwich Board Signs | P | P | P | | Section 7.10.1 Political Signs | P | P | P | P | Section 7.10.2
Added by Ord. No. 26-019, passed 4-21-2026.
Ask a question about Arlington law
Corpus searches the Arlington sections it holds and shows the ones that match, with their citations. Free, no sign-in.
