§ 5.4 — Site lighting and building illumination
Code of Ordinances, City of Oxford, Mississippi (Supp. No. 36: codified through Ordinance No. 2026-5, enacted March 17, 2026) · Oxford Code of Ordinances, App. A, art. 5.0, § 5.4
Corpus is an independent public-information project, not the official City of Oxford website. Stable reference: corpuslaw.us/code/97528f2f-7d8c-484e-8958-0189cc29fc52
Sec. 5.4. - Site lighting and building illumination.
5.4.1. Lighting and illumination generally. 5.4.1.1. Applicability. The provisions of this section shall apply to any and all exterior artificial light sources not otherwise having specific regulations specified within this Code. 5.4.1.2. Exemptions. The following are exempted from the requirements of this section: a. Lighting fixtures and standards required by federal, state, county or city agencies, including street lights within public rights-of-way. b. Outdoor lighting fixtures used or required by law enforcement, fire and emergency services, transportation or similar governmental agencies to perform emergency or construction repair work, or to perform nighttime road construction on major thoroughfares. 5.4.2. Site lighting standards. 5.4.2.1. Brightness. Streets, driveways, parking lots, walks and service areas shall be adequately illuminated as evenly as possible, not exceeding an average of .3 foot-candles diminishing to 0 at a boundary and demonstrated by a site lighting plan illustrating compliance. 5.4.2.2. A photometric survey prepared by a licensed design professional may be required by the director of planning to assist in discerning the planned lighting. 5.4.2.3. Site lighting shall not extend beyond site boundaries. Luminaries shall be shielded, shaded, or directed to prevent light from being cast on adjacent property. 5.4.2.4. Exterior lighting fixtures must be placed so that they do not interfere with the operation of vehicles. 5.4.2.5. No exterior light shall have any blinking, flashing, or fluttering light, or other illuminating device which has a changing light intensity or brightness of color. 5.4.2.6. Lighting fixtures shall be compatible in style with the architecture of their associated buildings. 5.4.2.7. Height of fixtures. Light fixtures (pole) should be proportional to the height and building mass of the structure but in no event shall exceed 25 feet. Freestanding light fixtures shall not exceed 14 feet when adjacent to a residential property. 5.4.2.8. Glare. There shall be no direct or reflected glare from floodlights, high temperature processing, combustion, welding, or otherwise, so as to be visible at the property line or right-of-way. 5.4.2.9. Safety hazard. Any artificial light source which creates glare observable within the normal range of vision from any public walk or thoroughfare under normal weather conditions is considered a safety hazard and is prohibited. 5.4.2.10. Nuisance. Any artificial light source which creates glare observable within the normal range of vision, under normal weather conditions, from any property other than the property where the light source is located is considered a nuisance and is prohibited. 5.4.3. Building lighting standards. Exterior lighting of buildings, properties, developments, signs or other features, and for any use, including, but not limited to, residential, commercial and industrial uses, shall meet all of the following requirements: 5.4.3.1. All exterior light fixtures shall be fully shielded and installed so that no direct light spills over onto adjacent properties or rights-of-way. 5.4.3.2. Because of their unique requirement for nighttime visibility and their limited hours of operation, stadiums, ball fields, playing fields and tennis courts are exempted from the general standards of this section. Lighting for these outdoor recreational uses shall be shielded to minimize light and glare trespass onto adjacent and nearby properties and public streets. They must, however, have a cut-off time established as a condition of approval. 5.4.3.3. No flashing, spinning, sweeping or strobing lights shall be permitted. 5.4.3.4. No installation or erection of any lighting which may be confused with warning signals, emergency signals or traffic signals shall be permitted. [image omitted; see the official code] 5.4.4. Mounting poles and fixtures. 5.4.4.1. Poles in commercial and multi-family developments, mounted upon a building or independently, shall not exceed 20 feet in height. 5.4.4.2. Pole mounted light fixtures shall be full cut-off that direct emitted light at 90 degrees or less. Where necessary, cut-off design fixtures or shields shall be installed to manage fugitive light throw. 5.4.4.3. Lighting fixtures within industrial developments shall not exceed 25 feet in height, except in those instances where the subject property adjoins any residentially zoned property, where poles may not extend above the building roof line. 5.4.4.4. Building mounted light fixtures shall be full cut-off to direct light at 45 degrees or less except for low intensity decorative lighting not exceeding 45 watts per bulb or incandescent equivalent.
Ask a question about Oxford law
Corpus searches the Oxford sections it holds and shows the ones that match, with their citations. Free, no sign-in.