§ 11-201.2 — National categorical pretreatment standards
Wilmington City Code, Delaware (Supp. No. 72: codified through Ordinance No. 25-073, enacted December 11, 2025) · Wilmington City Code § 11-201.2
Corpus is an independent public-information project, not the official City of Wilmington website. Stable reference: corpuslaw.us/code/97e6f50d-f7c8-4d3a-819a-497cf58fd649
Sec. 11-201.2 - National categorical pretreatment standards.
Users must comply with the categorical pretreatment standards found at 40 CFR Chapter I, Subchapter N, Parts 405—471 which are incorporated by reference herein. (1) Where a categorical pretreatment standard is expressed only in terms of the concentration of a pollutant in wastewater, the commissioner may impose equivalent mass limits in accordance with section 11-201.2(4). (2) When the limits in a categorical pretreatment standard are expressed only in terms of mass of pollutant per unit of production, the commissioner may convert the limits to equivalent limitations expressed either as mass of pollutant discharged per day or effluent concentration for purposes of calculating effluent limitations applicable to individual industrial users. (3) When wastewater subject to a categorical pretreatment standard is mixed with wastewater not regulated by the same standard, the commissioner shall impose an alternate limit in accordance with 40 CFR 403.6(e). (4) When a categorical pretreatment standard is expressed only in terms of pollutant concentrations, an industrial user may request that the city convert the limits to equivalent mass limits. However, in accordance with 40 CFR 403.6(c)(5)(iv), mass based limits may not be may not be granted for pollutants such as pH, temperature, radiation, or any other pollutants for which mass limits are not appropriate. The determination to convert concentration limits to mass limits is within the discretion of the commissioner. The city may establish equivalent mass limits only if the industrial user meets all the conditions set forth in subsections (4)a.1.—5. a. To be eligible for equivalent mass limits, the industrial user must: 1. Employ, or demonstrate that it will employ, water conservation methods and technologies that substantially reduce water use during the term of its individual wastewater discharge permit; 2. Currently use control and treatment technologies adequate to achieve compliance with the applicable categorical pretreatment standard, and not have used dilution as a substitute for treatment; 3. Provide sufficient information to establish the facility's actual average daily flow rate for all wastestreams, based on data from a continuous effluent flow monitoring device, as well as the facility's long-term average production rate. Both the actual average daily flow rate and the long-term average production rate must be representative of current operating conditions; 4. Not have daily flow rates, production levels, or pollutant levels that vary so significantly that equivalent mass limits are not appropriate to control the discharge; and 5. Have consistently complied with all applicable categorical pretreatment standards during the period prior to the industrial user's request for equivalent mass limits. b. An industrial user subject to equivalent mass limits must: 1. Maintain and effectively operate control and treatment technologies adequate to achieve compliance with the equivalent mass limits; 2. Continue to record the facility's flow rates through the use of a continuous effluent flow monitoring device; 3. Continue to record the facility's production rates and notify the commissioner whenever production rates are expected to vary by more than 20 percent from its baseline production rates determined in subsection (4)a.3. Upon notification of a revised production rate, the commissioner will reassess the equivalent mass limit and revise the limit as necessary to reflect changed conditions at the facility; and 4. Continue to employ the same or comparable water conservation methods and technologies as those implemented pursuant to subsection (4)a.1. as long as it discharges under an equivalent mass limit. c. When developing equivalent mass limits, the commissioner: 1. Will calculate the equivalent mass limit by multiplying the actual average daily flow rate of the regulated process(es) of the industrial user by the concentration-based daily maximum and monthly average standard for the applicable categorical pretreatment standard and the appropriate unit conversion factor; 2. Upon notification of a revised production rate, will reassess the equivalent mass limit and recalculate the limit as necessary to reflect changed conditions at the facility; and 3. May retain the same equivalent mass limit in subsequent individual wastewater discharger permit terms if the industrial user's actual average daily flow rate was reduced solely as a result of the implementation of water conservation methods and technologies, and the actual average daily flow rates used in the original calculation of the equivalent mass limit were not based on the use of dilution as a substitute for treatment pursuant to section 11-201.5. The industrial user must also be in compliance with section 11-212.3 regarding the prohibition of bypass. (5) Once included in its permit, the industrial user must comply with the equivalent limitations developed in this section in lieu of the promulgated categorical standards from which the equivalent limitations were derived. (6) Many categorical pretreatment standards specify one limit for calculating maximum daily discharge limitations and a second limit for calculating maximum monthly average, or four-day average, limitations. Where such standards are being applied, the same production or flow figure shall be used in calculating both the average and the maximum equivalent limitation. (7) Any industrial user operating under a permit incorporating equivalent mass or concentration limits calculated from a production-based standard shall notify the commissioner within two business days after the user has a reasonable basis to know that the production level will significantly change within the next calendar month. Any user not notifying the commissioner of such anticipated change will be required to meet the mass or concentration limits in its permit that were based on the original estimate of the long term average production rate.
(Ord. No. 11-009, § 1, 4-7-11)
Ask a question about Wilmington law
Corpus searches the Wilmington sections it holds and shows the ones that match, with their citations. Free, no sign-in.
