Sec. 41-70. - New or modified facilities.

All waste incinerators installed or modified after the effective date of this division (February 21, 1990), which must have a permit under chapter 33 of this Code, shall have the appropriate controls to assure compliance with emission levels identified in the operating permit. The following emission levels are the minimum acceptable; more stringent emission levels may be established by the environmental assessment and may be modified upon renewal: (a) Particulates. The particulate matter emissions limit shall be 0.015 grain per dry standard cubic foot adjusted to seven percent oxygen. (b) Acid gases. Hydrochloric acid emissions shall be no greater than 50 parts per million by volume corrected to seven percent oxygen on an hourly average as determined by EPA Method #26 or shall be reduced 90 percent by weight of uncontrolled emissions on an hourly average, whichever is less stringent. Sulfur dioxide emissions shall be no greater than 100 parts per million by volume corrected to seven percent oxygen hourly average as determined by EPA Method #8 or shall be reduced to 70 percent by weight of uncontrolled emissions on an hourly average, whichever is less stringent. (c) Carbon monoxide. Carbon monoxide emissions shall be no greater than 150 parts per million by volume corrected to seven percent oxygen on a dry basis as an instantaneous value and shall be no greater than 100 parts per million by volume corrected to seven percent oxygen on a dry basis for a 15-minute period. (d) Opacity. The opacity of all emissions except uncombined water shall not exceed ten percent for a six-minute running average in accordance with EPA Method #9. (e) Exhaust gas temperatures from the control device. The temperature of the exhaust gas from the control device shall have a maximum temperature of 300 degrees Fahrenheit. (f) Dump stack. The dump stack is to be used only when necessary to protect the pollution control device.

(Code 1980, § 41-70; Ord. No. 33102, § 1(41-70), 11-2-93)

Ask a question about Omaha law

Corpus searches the Omaha sections it holds and shows the ones that match, with their citations. Free, no sign-in.