§ 10-197 — Standards
Code of Ordinances, City of Winston-Salem, North Carolina (Supp. No. 103: codified through Ordinance No. 26-0283, enacted June 22, 2026) · Winston-Salem Code of Ordinances § 10-197
Corpus is an independent public-information project, not the official City of Winston-Salem website. Stable reference: corpuslaw.us/code/996feb9e-e0f1-417f-a5bb-e7d91a507919
Sec. 10-197. - Standards.
(a) Space and use standards. (1) A principal room shall have not less than 120 square feet. (2) A kitchen-dining room combination, shall have not less than 100 square feet. (3) A first bedroom, if any, shall have not less than 100 square feet. (4) A second bedroom, if any, shall have not less than 70 square feet. (5) Each habitable room shall have at least 70 square feet. (6) At least 120 square feet of floor space in habitable rooms shall be provided for the first occupant in each housing unit, at least 100 square feet of additional floor space shall be provided for each additional occupant (children one year of age and under shall not be counted). (7) At least 80 square feet of bedroom floor space shall be provided for the first occupant, and at least 30 square feet of additional bedroom floor space shall be provided for each additional occupant (children one year of age and under shall not be counted). (8) Those habitable rooms which must be included to meet the minimum space standards set out in this subsection shall be at least seven feet wide in any part, with at least one-half of the floor area having a ceiling height of at least seven feet. That portion of any room where the ceiling height is less than five feet shall not be considered as part of the floor area. (9) No basement space shall be used as a habitable room or housing unit unless: a. The floor and walls are impervious to leakage of underground and surface runoff water and are insulated against dampness. b. The total of window area in each room is equal to at least the window area sizes prescribed in this section for habitable rooms (see subsection (b) of this section, pertaining to light and ventilation standards). c. Such required window area is located entirely above the grade of the ground adjoining such window area. d. The total of openable window area in each room is equal to at least the area prescribed in this section for habitable rooms (see subsection (b) of this section, pertaining to light and ventilation standards), except where there is supplied some other device affording adequate ventilation and approved by the housing conservation administrator. (10) Toilet and bathing facilities shall be enclosed. (11) Access shall be provided to at least one toilet room without passing through a bedroom, except where every bedroom has direct access to a toilet room. (12) Access shall be provided to living rooms, kitchens and bedrooms without passing through a bedroom, except in a housing unit with only one bedroom. (13) Bathroom walls, toilet room walls and bedroom walls shall have no holes or excessive cracks. (14) Access shall be provided to all rooms within a dwelling unit without passing through a public space or other dwelling unit. (15) Doors shall be provided at all doorways leading to bedrooms, toilet rooms and bathrooms and at all rooms adjoining a public space. (16) Each living unit shall have a specific kitchen space, which contains a sink with counter work space and having hot and cold running water, and adequate space for storing cooking utensils. Minimum areas and dimensions of kitchen storage space shall be as follows: a. Minimum total area of shelving in wall and base cabinets shall be 30 square feet. b. Minimum drawer area shall be five square feet. c. Usable storage shelving in the cooking range or under the sink may be counted in the total shelving needed. d. Shelving shall be a minimum of 11½ inches in width. e. A minimum of four square feet of counter top shall be provided, not including the range top. (17) Clothes closet space should be provided within each living unit on the basis of approximately 12 square feet for the first bedroom plus six square feet for each additional bedroom. The space provided should be, if possible, divided into separate closets serving each bedroom and having one closet located so as to open directly off a hall or living or dining room. None of the minimum clothes closet space should be located within the kitchen. Where separate closets for each existing bedroom are not possible, a closet elsewhere within the living unit shall be acceptable only if the minimum clothes closet space for the dwelling unit is provided and the closet in question is reasonably accessible to the bedroom. Clothes closets should have a shelf and rod. Within each living unit, total shelf area or built-in drawer space of at least eight square feet should be provided for linens. This space should be increased two square feet for each additional bedroom. (18) Each living unit should have a designated closet or other suitable space within the unit or locked space elsewhere within the building or within an accessory building, conveniently accessible, for general storage. The minimum volume of general storage space for each housing unit should be 100 cubic feet and should be increased 32 cubic feet for each additional bedroom over two. (19) Toilet room, bathroom and bedroom doors shall be easily operable. (b) Light and ventilation standards. (1) Window area in each habitable room shall be at least eight percent of the floor area of such rooms and shall face directly to the outside. Whenever walls or other portions of structures face a window of any such room and such light-obstructing structures are located less than four feet from the window and extend to a level above that of the ceiling of the room, the window area shall be at least 20 percent of the floor area served by the window or 15 square feet, whichever is greater. Whenever walls or other portions of structures are located less than six feet but at least four feet from the window and extend to a level above that of the ceiling of the room, the window area shall be at least 15 percent of the floor area served by the window or 12 square feet, whichever is greater. (2) Openable window area in each habitable room shall be at least one-half of the minimum window area. (3) All windows and doors opening to the outside shall be adequately screened, unless the room or unit is served by an approved ventilating system. (4) Windows and doors shall be reasonably weathertight, shall have no broken glass, and shall have adequate operable locks and hardware. (5) Natural ventilation of spaces such as attics and enclosed basement space should be provided by openings of sufficient size to overcome dampness and to minimize the effect of conditions conducive to decay and deterioration of the structure, and to prevent excessive heat in attics. (6) Utility spaces containing heat-producing, air conditioning and other equipment shall be ventilated to the outer air, and inside air from such activity utility spaces shall not be recirculated to any dwelling unit. (7) All glazing materials shall be maintained free from cracks and holes. (8) Every window, other than a fixed window, shall be easily openable and capable of being held in position by window hardware. (9) Clothes dryer exhaust systems shall be independent of all other systems, be exhausted to the outside in accordance with the manufacturer's instructions. (c) Exit standards. (1) Two main exits, each at least 30 inches wide and six feet eight inches high, easily accessible to the occupants of each housing unit, shall be provided, unless a single exit is permitted as an exception by provisions of the 1994 edition of the North Carolina State Building Code, as from time to time amended. All exit doors shall be easily operable. (2) Steps or handrails shall be provided to serve exits and retained in safe condition. (3) All exterior doors, door assemblies, and hardware shall be easily openable and maintained in good condition. (4) Entrance locks shall tightly secure the door. (5) Every common hall and stairway in other than one and two family dwellings shall be lighted at all times with at least a 60 watt light bulb for each 200 square feet of floor area. Spacing between lights shall not exceed 30 feet. (6) Bars, grills, grates, or similar devices shall be releasable or removable from the inside without the use of a key, tool, or force greater than required for normal operation of the opening. (d) Plumbing standards. (1) The plumbing system shall be connected to the city sanitary sewer system where available; otherwise, the plumbing system shall be connected onto an approved septic tank. (2) All fixtures shall be properly installed, maintained in working order, capable of performing the function for which it was designed and in a safe, sanitary, and functional condition. (3) Water closet bowls shall not be broken. (4) Water closets shall not be loose or leaking. (5) Shower stall floors shall have no leaks. (6) Fixtures shall not be cracked, broken or badly chipped. (7) There shall be no hopper bowl toilets. (8) There shall be provided a hot water heater (minimum 40-gallon capacity) furnishing hot water to each tub or shower, lavatory and kitchen sink; provided, however, that each one-bedroom unit is required to have a minimum 30-gallon capacity hot water heater. A drainpipe, discharge tube, shall be attached to the pressure relief valve and terminate within six inches of floor level. (9) An installed water supply inside the building shall be provided for each housing unit. The water supply shall be connected to either a public water system or an approved private water system. (10) An installed water closet, tub or shower, lavatory and sink shall be provided for each housing unit. The kitchen sink shall be at least 12 inches by 12 inches and shall be at least six inches deep. (11) Separate toilet facilities shall be provided for each housing unit. (12) Toilet and bathing facilities shall be protected from the weather. (13) All water piping shall be protected from freezing by proper installation in protected space. (14) At least one main vent of a minimum diameter of two and one-half inches shall be properly installed for each building. (15) Sewer and water lines shall be properly supported, with no broken or leaking lines. (16) Every water closet compartment floor surface and every bathroom floor surface shall be so constructed and maintained as to be reasonably impervious to water and as to permit such floor to be readily kept in a clean and sanitary condition. (17) The arrangement of fixtures shall provide for the comfortable use of each fixture and shall permit at least a 90-degree door swing. Wall space shall be available for a mirror or medicine cabinet and towel bars. Bathtubs shall be not less than four feet six inches long, and, if a square tub, four feet minimum. Shower floors, if a shower is provided instead of a bathtub, shall have a least dimension of not less than 30 inches. (18) Adequate space should be provided for home laundry equipment (washing machine and dryer) in either of the following locations: a. Within each living unit having two or more bedrooms, and located in the kitchen or other suitable service space; or b. In the basement, cellar or other suitable public space within the building for the use of all occupants. (19) A kitchen sink shall not be used as a substitute for a lavatory. (20) Hazards due to inadequate service, inadequate venting, cross connection, backsiphonage, improper installation, deterioration or damage shall be corrected. (21) All kitchen sinks, lavatories, laundry facilities, bathtubs and showers shall be supplied with hot and cold running water. (22) An approved pressure relief valve shall be installed and maintained on water heaters. (23) Every plumbing stack, vent, waste, and sewer line shall function properly and be kept free from obstructions, leaks, and defects. (24) Every dwelling unit shall be maintained so as to prevent persistent excessive dampness or moisture on interior or exterior surfaces. Building materials discolored or deteriorated by mold or mildew shall be cleaned, dried, and repaired. (e) Heating standards. (1) Heating facilities. Every dwelling and dwelling unit shall be provided with a heating unit which is properly designed, installed and balanced or adjusted, maintained in good and safe condition and which is capable of safely and adequately heating all habitable rooms, bathrooms and water compartments located therein to a temperature of 68°F (20°C). The required room temperatures shall be measured three feet above the floor near the center of the room and two feet inward from the center of each exterior wall. Either central or space heating units designed for continuous use may be used. Portable or temporary space heaters are strictly prohibited as a primary source of heat, but may be used to supplement heating. (2) Central heating units. a. Every central heating unit shall: 1. Have every duct, pipe or tube free of leaks and functioning properly; 2. Be provided with proper seals between sections of hot air furnaces to prevent the escape of noxious fumes and gases into heat ducts; 3. Be properly connected to an electric circuit of adequate capacity in an approved manner if electrical power is required; and 4. Be provided with all required automatic or safety devices and be installed and operated in the manner required by the laws, ordinances and regulation of the city. b. All liquid fuel used to operate any central heating unit shall be stored in accordance with the city's fire prevention and building codes. c. All gas and oil heating equipment installed on the premises shall be listed by a testing laboratory and shall be installed, including proper ventilation, in accordance with the applicable provisions of the North Carolina State Building Code. (3) Space heating units. a. Every space heating unit shall: 1. Not use gasoline or other similar highly flammable liquid fuel; 2. Not be of portable type using solid, liquid or gaseous fuel; 3. Be properly connected according to the manufacturer's instructions on installation; 4. Be so located or protected as to prevent any overheating of adjacent combustible material; 5. If employing electricity, be connected to a circuit of adequate capacity in an approved manner; 6. Be provided with all required automatic or safety devices; and 7. Be installed under permit and be properly operated. b. A kerosene space heater which has its fuel piped to the heater from a remotely installed bulk tank shall be permissible under this section. Other portable kerosene space heaters are strictly prohibited as a primary source of heat. c. All unvented gas-fired heating units are strictly prohibited, as a primary source of heat and as a secondary source of heat in bedrooms and sleeping areas. d. Ornamental gas logs may be installed in a fireplace provided that such installation is in compliance with the applicable portions of the North Carolina State Building Code. (4) Fireplaces and chimneys. The following standards and conditions shall be applicable to fireplaces and chimneys unless rendered inoperable: a. Chimneys shall be tight and safe, and capable of maintaining proper draft for carriage of combustion by-products to outside air. b. Chimneys shall be kept clean of soot and other debris. c. No holes shall be permitted in flue, except for necessary vent connections and clean out doors. d. All existing hanging masonry chimneys shall be removed. e. Thimbles shall be grouted in tight. f. Thimbles shall be located high enough to provide proper draft for the heating appliances served thereby. g. Fireplaces may be used only for supplemental heat and not as the primary heating source for a dwelling. This section does not exclude the use of wood burning stoves or inserts as the primary heating source for a dwelling. h. The hearth and the hearth extension shall extend a minimum of 36 inches from the back of the firebox to the end of the hearth extension. The hearth extension shall extend at least 16 inches in front of and at least eight inches beyond each side of the fireplace opening. Where the fireplace opening is six square feet or larger, the hearth extension shall extend at least 20 inches in front of and at least 12 inches beyond each side of the fireplace opening. i. No combustible materials shall be permitted within seven inches of the top and seven inches of either side of the fireplace opening. j. Where fireplace is closed and converted to other use, there shall be masonry closure of face and proper lining or vent installed in chimney where same does not exist. (f) Electrical standards. (1) No receptacles, ceiling fixtures or other fixtures shall be broken or hanging loose. (2) All toggle switches and fixtures shall be safely operable. (3) At least two duplex convenience outlets, as remote from each other as practicable, shall be provided per habitable room. (4) At least one light outlet shall be provided in each bathroom, kitchen, hall and porch, and over exterior steps to the second floor. (5) There shall be no bare wires, open joints or spliced cables. (6) Flexible cords shall not be used as a substitute for the fixed wiring of a structure, nor shall flexible cords be run through holes in walls, ceilings or floors, or through doorways, windows or similar openings, or be attached to building surfaces or concealed behind building walls, ceilings or floors. (See article 400-4 of the National Electrical Code.) (7) No branch circuits shall be overloaded. (8) Fuses shall be sized correctly and not bridged out. (9) A minimum of three branch circuits, plus separate circuits for each fixed appliance, shall be provided in each dwelling unit. (10) There shall be provided service equipment and a lighting panel of adequate capacity and size (minimum of 100-ampere capacity) to accommodate the existing or the required number of branch circuits, and the equipment shall be properly grounded. (11) All electrical equipment, wiring, and appliances shall be properly installed and maintained in a safe manner. (12) Flexible cords or extension cords shall not be used to provide power to appliances. (13) Face plates shall be attached to receptacles and to switches and shall be free of cracks and of breaks. (14) Receptacles and switches shall not be painted over. (15) Service panels shall be free of missing blanks and missing knock-outs. (g) Structural standards. (1) Foundation. a. A foundation shall support the building at all points and shall be free of all holes and cracks which admit rodents, water or dampness to the interior of the building or which lessen the capability of the foundation to support the building. b. The foundation shall be on firm, reasonably dry ground, and there shall be no water standing or running under the building. c. Footings shall be sound and have adequate bearing capacity. d. Piers shall be sound. e. No piers in which the plumb line from top center falls outside the middle one-third of the pier base shall be allowed. f. There shall be no isolated masonry piers exceeding in height ten times the least horizontal dimension of the pier. g. Adequate foundation drainage shall be provided and maintained so as to prevent standing water or other conditions so as to avoid the presence of mold. Crawlspaces shall be free of high-moisture conditions or sealed from dwelling areas. h. No wood stiff-knees or other improper piers shall be allowed. i. The space between the ground and the first floor of every dwelling shall be enclosed with masonry or other permanent material of at least one-half inch in thickness, except where underpinning is not consistent with the architecture of the dwelling, as determined by the housing conservation administrator or his designee. Where wood is used as underpinning, such wood, in addition to the conditions set out in this subsection, shall be weather treated and permanently affixed. Where no underpinning is required, the ground level floor shall be substantially weathertight and insulated to R-19 value. j. All crawl space doors and access doors shall be maintained to prevent entrance of rodents, rain, and surface drainage water. (2) Floors. a. No rotted or termite-damaged sills shall be allowed. b. No broken, seriously fire damaged, overloaded or sagging sills shall be allowed. c. Sills shall be reasonably level. d. Sills shall be properly and sufficiently supported. e. Sills shall clear the ground by at least 15 inches. f. No rotted, seriously fire damaged, or termite-damaged joists shall be allowed. g. No broken or sagging joists shall be allowed. Sagging joist deflection exceeds 1/360 where 1 is the unsupported length between bearing points. h. Reserved. i. There shall be no two-inch by four-inch floor joists. j. Reserved. k. Joists shall be properly bridged at midspan when the span exceeds ten feet. l. Flooring shall be weathertight, without holes or cracks which permit air excessively to penetrate rooms. m. Flooring shall be reasonably smooth, not rotten or worn through. n. No loose flooring nor floor covering shall be allowed. Throw rugs and area rugs shall be exempt from this provision. o. Floors shall be reasonably level. p. Replacement of structural members shall require a building permit (G.S. 143-138(b) as amended) and shall be in accordance with the State Building Code. (3) Exterior walls. a. No wall in which a plumb line from top center of the studs falls outside the base plate at any point along the wall shall be allowed. b. Reserved. c. No studs which are rotted, seriously fire damaged, or termite-damaged shall be allowed. d. No broken or cracked structural members shall be allowed. e. The maximum permissible spacing, horizontal or vertical, for lateral support shall be eight feet zero inches except where steel reinforced. f. All siding shall be weathertight, with no holes, cracks or rotted boards which permit air excessively to penetrate rooms. g. No loose siding shall be allowed. h. All exterior surfaces, other than decay resistant materials, shall be protected from the elements and decay by painting or other protective covering or treatment. i. All siding and masonry joints as well as those around windows, doors, and skylights shall be maintained weather resistant and water tight. j. Replacement of structural members shall require a building permit (G.S. 143-138(b) as amended) and shall be in accordance with the State Building Code. (4) Interior walls. a. The interior finish shall be free of holes and cracks which permit air excessively to penetrate rooms. b. No walls in which a plumb line from top center of the studs falls outside the base plate at any point along the wall shall be allowed. c. No loose plaster, loose boards or other loose wall materials shall be allowed. d. There shall not be allowed as a wall finish any cardboard, newspaper or other highly combustible material. e. Reserved. f. No studs shall be rotted, seriously fire damaged, or termite damaged. g. No broken or cracked studs or other broken or cracked structural members shall be allowed. h. Reserved. i. All materials in high moisture areas shall be protected from decay and deterioration by painting or a protective covering. j. Peeling, chipping, or flaking paint shall be repaired or removed and the surface covered with a protective coating. k. Interior doors shall fit reasonably well within the frame and shall be capable of being opened and closed easily. l. Replacement of structural members shall require a building permit (G.S. 143-138(b) as amended) and shall be in accordance with the State Building Code. (5) Ceilings. a. No joists shall be rotted, seriously fire damaged, broken or sagging or have improperly supported ends. b. Reserved. c. Reserved. d. There shall be allowed no holes or cracks which permit air excessively to penetrate rooms. e. No loose plaster, loose boards, loose sheetrock or other loose ceiling finish shall be allowed. f. There shall not be allowed as ceiling finishes any cardboard or other highly combustible material. g. Replacement of structural members shall require a building permit (G.S. 143-138(b) as amended) and shall be in accordance with the State Building Code. (6) Roof. a. Rafters shall not be rotted, broken, sagging or have improperly supported ends. b. No rafters seriously fire damaged shall be allowed. c. The maximum permissible interval for the bracing and tying of rafters shall be four feet zero inches o.c. d. Attics shall be properly vented. e. No rafters shall be nearer than two inches to any chimney. f. No rotted, loose or sagging sheathing shall be allowed. g. No loose roof covering shall be allowed, nor shall there be allowed any holes or leaks which could cause damage to the structure or rooms. h. The roof covering shall be at least class C, as defined by the State Building Code. i. Walls and chimneys shall have proper flashing. j. Roof drains, gutters and downspouts shall be maintained in good repair and free from obstructions. k. Replacement of structural members shall require a building permit (G.S. 143-138(b) as amended) and shall be in accordance with the State Building Code. (7) Porches. a. The foundation, floor, ceiling and roof shall be equal to standard as set forth in this section, except sills and joists need not be level if providing drainage of floors, floors need not be weathertight, floors need not be level if providing for drainage, ceiling height shall be not less than seven feet zero inches, and the attic need not be vented. b. Posts and railings shall not be rotted or termite damaged. c. Every porch, terrace or entrance platform located at least 36 inches above the adjacent finished grade shall be equipped with railings not less than 30 inches high. (8) Stairs and steps. a. Stairs and steps shall be free of holes, grooves and cracks large enough to constitute accident hazards. b. Stairwells and flights of stairs, attached to or within a dwelling unit, that contain more than four risers shall have rails not less than two feet six inches measured vertically from the nose of the treads to the top of the rail. c. Every rail shall be firmly fastened and maintained in good condition. d. No flight of stairs settled more than one inch out of its intended position or pulled away from supporting or adjacent structures shall be allowed. e. No rotting, sagging or deteriorated supports shall be allowed. f. Every stair tread shall be uniform in height, sound and securely fastened in position, and strong enough to bear a concentrated load of at least 400 pounds without danger of breaking through. (9) All accessory buildings and structures, including detached garages, shall be maintained structurally sound and in good repair or shall be razed to grade level and the debris therefrom removed from the premises. (10) Where applicable because of the number of dwelling units in a structure, the fire resistance rating requirements of the State Building Code shall apply to party walls and ceilings. (h) Property maintenance. (1) Buildings and structures. a. Exterior wood surfaces not inherently resistant to deterioration shall be treated with a protective coating of paint or other suitable preservative with sufficient frequency to prevent deterioration. b. Floors, walls, ceilings and fixtures shall be maintained in clean and sanitary condition. (2) Public areas. Every owner of a structure containing two or more dwelling units shall be responsible for maintaining in a clean and sanitary condition the shared or public areas of the structure and premises thereof. (3) Rubbish and garbage disposal. Every person who occupies and controls a dwelling unit shall dispose of all rubbish and garbage in a clean and sanitary manner by placing it in proper storage facilities. In the case of single-family and two-family dwellings, the persons who occupy and control the dwellings shall be responsible for providing the receptacles for disposing of garbage and rubbish. In the case of multifamily housing, the owner shall be responsible for providing the receptacles for the storage of garbage and rubbish. In all cases, the receptacles shall meet the specifications set out in section 26-3. (4) Interior cleanliness and safety. Every occupant of a dwelling unit shall be responsible for the following as applied to that unit which he occupies or controls: a. The occupant shall keep the occupied area and all facilities in a clean and sanitary condition. A clean and sanitary condition shall include but is not limited to the following: 1. Floors, floor coverings and other walking surfaces shall be kept clean and free of dirt, filth, garbage, fecal matter, litter, refuse and other insanitary matter. 2. Walls, ceilings, windows and doors shall be kept clean and free of dirt, greasy film, soot and any other insanitary matter. 3. Plumbing fixtures shall be kept in a clean, sanitary and operable condition. No materials shall be deposited in any such fixture which may result in the obstruction of such fixture or any lines connected thereto. 4. The cookstove, refrigerator, cabinets and other furnishings shall be kept clean and free of dirt, greasy film, soot and any other insanitary condition. b. No occupant shall destroy, deface, damage, impair or carry away any of the facilities, equipment or appurtenances or any part of the dwelling unit or rooming unit. c. No occupant shall obstruct in any manner any means of egress from any portion of the premises. (5) Premises. a. Fences and other minor structures shall be maintained in a safe and substantial condition. b. Yards and courts shall be kept clean and free of physical hazards, rubbish, trash and garbage. c. No heavy undergrowths or accumulations of plant growth which are noxious or detrimental to health shall be allowed. d. Every premises shall be provided with vehicular access to and from the premises at all times by an abutting public or private street. e. Walks and steps, constructed so as to provide safety, reasonable durability, and economy of maintenance, should be provided for convenient all-weather access to the structure. f. Access to the rear yard from each dwelling unit shall be required. Such access is not, however, acceptable where it is dependent upon passage through another dwelling unit. Each building shall be provided with access to the rear yard. This access for a detached dwelling shall be directly from a street. g. Any nonresidential use of the premises shall be subordinate to its residential use and character. h. All sidewalks, walkways, stairs, driveways, parking spaces and similar spaces shall be kept in a proper state of repair and maintained free from hazardous conditions. (6) Infestation. a. Premises, buildings and structures shall, by generally accepted methods of extermination, be maintained free of vermin and rodent harborage and infestation. b. Every basement or cellar window used or intended to be used for ventilation and every other opening to a basement or cellar which might provide an entry for rodents shall be supplied with screens installed or with such other approved devices as will effectively prevent entrance by rodents. c. Every head-of-household occupant of a structure containing a single dwelling unit shall be responsible for the extermination of any insects, rodents or other pests therein or on the premises. Every head-of-household occupant of a dwelling unit in a structure containing more than one dwelling unit shall be responsible for such extermination whenever his dwelling unit is the only one infested. Whenever infestation is caused by failure of the owner to maintain a structure in a rodentproof or reasonably insect proof condition, extermination shall be the responsibility of the owner. Whenever infestation exists in two or more of the dwelling units in any structure or in the shared or public parts of any structure containing two or more dwelling units, extermination shall be the responsibility of the owner. (7) All appliances and fixtures. All appliances and fixtures shall be installed in accordance with the manufacturer's instructions and shall be maintained in a safe manner. (8) Vacant structures. All vacant structures shall be maintained secure at all times. (i) Insulation. Ceiling insulation rated at least R-19, or a minimum thickness of four inches of insulation when approved by the housing conservation administrator, and consisting of rock wool (glass) or fiberglass, or other materials exhibiting fire resistant capacities equal to or greater than rock wool or fiberglass, shall be required in the ceilings of all dwellings within 30 months after April 8, 1980. (j) Weatherization. All structures shall be weatherized as set forth in subsections (b)(4) and (6), (g)(1)a, (g)(2)l, (g)(3)f, (g)(4)a, (g)(5)d and (g)(6)d and i of this section. (k) Additional requirements for roominghouses. (1) No person shall operate or cause to be operated any roominghouse, unless there are provided: a. Lavatory facilities consisting of one flush water closet, one washbasin and one bathtub or shower for every six persons residing in the roominghouse. b. Access within the roominghouse to lavatory facilities without entering another rooming unit. c. Walls, floors and ceilings maintained in a sanitary condition. d. Prompt and sanitary disposal of all garbage. (2) All furnace rooms which are not in an open basement shall be enclosed with a material having at least a one-hour protection rating. (3) No person shall operate or cause to be operated any roominghouse that permits the heating or cooking of food within a rooming unit. (l) Smoke detectors. (1) Within six months after February 11, 1992, each occupied dwelling unit shall be required to contain at least one operable smoke detector installed outside the sleeping area, to be located on or near the ceiling. (2) Detectors shall be electrically or battery operated and provide an audible alarm when activated. (3) For purposes of this subsection, the term "operable" is defined as working when a battery is inserted or the electricity is on; however, the landlord is not obligated to provide the battery or the electricity. (4) Notwithstanding the provisions of this subsection, where the State Building Code requires the installation of an electrical smoke detector or alarm, that code or provision shall apply. (5) Effective 18 months from adoption, each room designated for sleeping purposes, or used for sleeping more than occasionally, or listed as a bedroom on a set of plans and each story, excluding crawl space and attic space, shall be required to contain a smoke detector located on the ceiling and no closer than 12 inches to the intersection of the wall and the ceiling. (m) Carbon monoxide alarms/detectors. (1) By December 1, 2018, each existing occupied dwelling unit shall have at least one operable carbon monoxide alarm per level, either battery-operated or electrical, that is listed by a nationally recognized testing laboratory that is OSHA-approved to test and certify to American National Standards Institute/Underwriters Laboratories Standards ANSI/UL2034 or ANSI/UL2075, installed and maintained in accordance with either the standards of the National Fire Protection Association or the minimum protection designated in the manufacturer's instructions. This provision applies only to dwelling units having a fossil-fuel burning heater, appliance, or fireplace, and in any dwelling unit having an attached garage. This provision applies to the existing dwelling units not currently covered by the Residential Code Section of the North Carolina State Building Code. (2) The term "operable" is defined as working when a battery is inserted or the electricity is on; however, this code does not obligate the landlord to provide the battery or the electricity.
(Code 1975, § 4-93; Ord. No. 4493, § 1, 6-21-04; Ord. No. 4629, §§ 1, 2, 8-18-08; Ord. No. 29216, §§ 2, 3, 2-19-18; Ord. No. 2021-18, § 1, 6-21-21)
Ask a question about Winston-Salem law
Corpus searches the Winston-Salem sections it holds and shows the ones that match, with their citations. Free, no sign-in.
