§ 42-310 — Location, material, etc., of gasoline storage tanks
Wilmington City Code, Delaware (Supp. No. 72: codified through Ordinance No. 25-073, enacted December 11, 2025) · Wilmington City Code § 42-310
Corpus is an independent public-information project, not the official City of Wilmington website. Stable reference: corpuslaw.us/code/99d40555-60c2-42d8-ab59-6757ac1df452
Sec. 42-310. - Location, material, etc., of gasoline storage tanks.
Tanks and pipes connected therewith for the storage and conveyance of gasoline, or other similar products under whatsoever name designated, having a flash point under 120 degrees Fahrenheit, installed, maintained and used under permits from the department of licenses and inspections, shall conform to the following requirements: (1) Such storage tanks shall be located as designated by the department of public works. (2) The top of the storage tank shall be at least three feet below the sidewalk level; provided, that they are not within 20 feet of any excavation, cellar, cellarway or basement. (3) If within 20 feet of any excavation, cellar, cellarway or basement, the top of the storage tank shall be placed below the lowest point of such excavation, cellar, cellarway or basement. (4) Where the sidewalk is excavated and used as part of a basement, or where it is impracticable to place the storage tank as required under subsection (c) of this section, a concrete receptacle or box, the bottom, sides and ends of which shall be not less than 12 inches in thickness, shall be constructed around such storage tank, extending up to the top of such tank, and the space between the tank and the walls thereof, and the space between the top of the tank and the sidewalk, which shall be not less than three feet, shall be filled with earth. The concrete to be used in such construction shall be a 1-1½-3 mixture, meaning one cubic foot, or one bag, of cement, 1½ cubic feet of sand and three cubic feet of three-quarter inch stone, with sufficient water. (5) Such storage tanks shall be of either steel or iron. Steel tanks shall be of not less than No. 14 galvanized, riveted steel to steel joints, soldered. Iron tanks shall be of not less than 3/16 of an inch in thickness, riveted, caulked or welded. All tanks shall be coated with tar or other rust-resisting material. (6) No one storage tank shall contain more than 1,000 gallons of gasoline or similar product. No gasoline or similar product shall be stored or used in any tank installed and maintained under permit from the department of licenses and inspections other than meets with the requirements of the fire code of the city relating to the storage of gasoline or similar products. (7) All such tanks for the storage of gasoline or similar products, as hereinbefore defined, shall be connected with an automatic closing pump. No such pump shall be located upon any portion of the sidewalk, footway or roadway of any street of the city. It shall be unlawful to install or use any pump in connection with any tank installed under permit from the department of licenses and inspections, other than of a type approved by the bureau of fire, and for which approval shall have been granted by the fire department.
(Code 1968, § 45-112; Ord. No. 92-053(sub 1), § 1(b), 7-2-92)
Ask a question about Wilmington law
Corpus searches the Wilmington sections it holds and shows the ones that match, with their citations. Free, no sign-in.