For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 11-31-16 — LARGE COMMERCIAL DEVELOPMENT

Mesa City Code (Supp. No. 22: codified through Ordinance No. 5996, adopted March 9, 2026) · Mesa City Code § 11-31-16

Corpus is an independent public-information project, not the official City of Mesa website. Stable reference: corpuslaw.us/code/9a14369f-9288-4dc5-ad64-ef3f5f143648

11-31-16: - LARGE COMMERCIAL DEVELOPMENT

Large Commercial Development, as described in Section 11-86-4, shall be located, developed and operated in compliance with the land use regulations in Article 2, and the following standards: A. Chapter 6 Standards Apply. In addition to the requirements below, Large Commercial Development shall comply with all requirements of Section 11-6-3 (Development Standards) and Section 11-6-4 (Site Planning and Design Standards). B. Customer Entrances. All building entries designed for general public and customer access to the building shall be clearly distinguishable from the remainder of the building and incorporate one (1) or more of the following design elements: 1. The façade shall be articulated at least 10 feet horizontally and four (4) feet vertically for the full height of the entry feature; 2. The entryway shall contain a minimum 75% glazing; 3. The entryway shall be defined by a distinct change in building material; 4. The entryway shall include a distinct change in roof form (e.g., curvilinear versus flat parapet, tower feature, angled versus flat, etc.); or 5. Other architectural features as approved by the Planning Director. C. Entryway Monumentation Feature. Each large commercial development shall provide at least one (1) entryway monumentation feature at a primary driveway serving an arterial or collector street. The entryway monumentation feature shall consist of: 1. A landscaped median measuring at least seven (7) feet in width; 2. A landscaped roundabout; 3. An architectural gateway (e.g., paired columns with overhead element); or 4. Other feature(s) approved by the Planning Director. D. Entryway Plazas. An entryway plaza shall be provided at the entry to each anchor tenant building. 1. Minimum size. The entryway plaza shall have a minimum area of 900 square feet and extend at least 20 feet, perpendicular from the public entrance. 2. Design Elements. The entryway plaza shall include decorative paving, seating areas, raised planters, or trees. E. Open Space. Open space shall be provided as follows: 1. Minimum area. a. Five (5) square feet per 1,000 square feet of building gross floor area shall be provided for open space. b. Each area designated as open space shall be no less than 200 square feet in area. c. Required sidewalks shall not be included in the open space calculation. 2. Location. a. Required open space shall be visible from a public street, or from on-site areas normally frequented by customers. b. Required open space shall be accessible during business hours. c. Entryway plazas and areas designated for customers to wait for rideshare services may be combined with required open space. 3. Shade. a. Required. At least 50% of the required open space shall be shaded by trees, shade structures, or other permanent elements integrated into the site design. b. Measuring Shade. Shade coverage shall be measured at 3:00 p.m. on the summer solstice and verified through a shadow study. For the purpose of shade calculations, tree canopies shall be evaluated based on their projected growth five (5) years after planting. 4. Amenities. Required open space shall include amenities, in addition to required shade elements. amenities may include seating areas; water and cooling features (e.g., drinking fountains, splash pads, etc.); play, fitness, and recreation equipment; mobility stations (e.g., bike repair station, micromobility docks, wayfinding kiosks/maps); pop-up/activation space (e.g. performance stage, stubs outs for electric, water, etc.); public art; or other amenities as determined by the Planning Director to provide equivalent functional or recreational value. F. Criteria for Review of Council Use Permit. When a Council Use Permit is required, City Council shall find the project complies with all of the following: 1. The project complies with the General Plan and any other applicable Plans and/or policies. 2. A Plan of Operation has been submitted, which includes, but is not limited to, acceptable evidence of compliance with all zoning, building, and fire safety regulations. 3. A "Good Neighbor Policy" in narrative form has been submitted, which includes, but is not limited to, descriptions of acceptable measures to ensure ongoing compatibility with adjacent uses, including sound attenuation, lighting control measures, and vehicular access and traffic control. Such policies shall include, but are not limited to: a. The name and telephone number of the position, manager or person responsible for the operation of the facility; b. Complaint response procedures, including investigation, remedial action, and follow-up; and c. Litter control measures. 4. Evidence that the building or site is in, or will be brought into substantial conformance with all current City Development Standards, including, but not limited to, landscaping, parking, screen walls, signage, and project-specific design guidelines. 5. Evidence that the project is designed to: a. Provide paved parking and on-site circulation in a manner that minimizes impacts on adjacent sites; and b. Minimize dust, fugitive light, glare, noise, offensive smells, and traffic impacts on neighboring residential sites.

(Ord. No. 5544, § 10, 12-9-19; Ord. No. 5928, § 21, 2-3-25; Ord. No. 5996, § 4, 3-9-26)

Ask a question about Mesa law

Corpus searches the Mesa sections it holds and shows the ones that match, with their citations. Free, no sign-in.