For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 15.01.130 — Building permit exemptions

Henderson Municipal Code (Supp. No. 59: codified through Ordinance No. 4163, adopted June 16, 2026) · Henderson Municipal Code § 15.01.130

Corpus is an independent public-information project, not the official City of Henderson website. Stable reference: corpuslaw.us/code/9a934ccd-1962-49bb-9b5e-ae0f4311b533

15.01.130 - Building permit exemptions.

A building permit shall not be required for the following: A. Buildings, structures, or service equipment and installations directly used in utility generation or distribution which are installed on properly recorded easements and rights-of-way belonging to water, gas, power, telephone or other utility companies that are preemptively regulated and governed by the Nevada Public Service Commission, State of Nevada Charter, or other governmental entity. This exemption does not include site preparation, block walls, fences or habitable public areas such as offices, meeting rooms, and public service counters. B. Improvements such as traffic lights, streets, curbs, gutters, sidewalks, drainage facilities, bus stops and similar improvements constructed on public property or in a public easement or right-of-way. C. One-story detached accessory buildings in conjunction with a single family dwelling used as tool or storage sheds, playhouses and similar uses provided the floor area does not exceed 200 square feet; D. Movable cases, counters and partitions not over five feet nine inches high; E. Water tanks supported directly on grade if the capacity does not exceed 5,000 gallons and the ratio of height to diameter or width does not exceed two to one; F. Walks and driveways not more than 30 inches above grade and not part of an accessible route or means of egress and not over any basement or story below; G. Exterior stairways on-grade and not part of an accessible route or means of egress; H. Platforms, decks and similar structures not more than 30 inches in height above grade in conjunction with a single-family dwelling; I. Painting, papering and similar finish work; J. Structures, booths, sets, and scenery used for motion picture, conventions, television shows, theaters, shows, special events, and similar temporary uses; K. Window awning supported by an exterior wall of one- and two-family dwellings and garages accessory thereto when projecting not more than 54 inches; L. A storable swimming or wading pool as defined in the pool code that is accessory to a single-family dwelling and in which the pool walls are entirely above the adjacent grade; M. Pre-manufactured fabric sun shade and carport structures, wood gazebos and similar structures used in conjunction with a single-family dwelling and not exceeding 200 square feet in area and not permanently affixed to an existing building nor anchored to a permanent foundation; N. Fences in rear yards without permanent foundations and not over four feet in height; O. Fences not over 24 inches in height at any location; P. Retaining walls that are not more than 24 inches in height measured from the top of the footing to the top of the wall; Q. Hazardous material storage tanks regulated by the fire code; R. Storage sheds and portable or mobile offices, including construction trailers not exceeding 400 square feet, on an active construction project site; S. Livestock shade structures open on three sides and not more than 1,500 square feet in area; T. Non-motorized playground equipment; U. Storage racks less than or equal to eight feet in height unless designated as high-pile storage; V. Portable spas accessory to a single-family dwelling with all heating and circulating equipment integral to the manufactured product; W. Underground structures and facilities housing mechanical equipment constructed by a political subdivision of the State of Nevada and not intended for human habitation; X. Replacement of existing exterior and interior windows, doors and similar openings not requiring enlargement of the wall opening; Y. Replacement of existing roofing material of the same or higher class and the same or lighter material and not involving replacement of sheathing; Z. Installation of additional layers of roofing material over existing roof covering not exceeding the maximum allowable number of layers; AA. Minor repair of interior or exterior wall covering, such as stucco and drywall, provided the repair area does not exceed ten square feet and the repair work is not performed in conjunction with any other permit; BB. Structures containing technical service equipment used for meteorological sampling or air quality sampling and testing by local, state or federal government agencies provided the structure does not exceed 240 square feet in area. Exemption from the permit requirements of this chapter does not authorize any work to be done in violation of the provisions of this chapter, the technical codes, or any other pertinent ordinances, laws or regulations of the City of Henderson.

(Ord. No. 3906, § 2, 9-13-2022; Ord. No. 3141, § 1, 4-1-2014; Ord. 2736, § 1 (part), 2008)

Ask a question about Henderson law

Corpus searches the Henderson sections it holds and shows the ones that match, with their citations. Free, no sign-in.