Sec. 31-117. - General requirements.
(a) Submission for certification of final plat approval shall consist of the document and two (2) transparent originals (one (1) shall be a Mylar), the number of prints as established by the planning staff, the certificates specified in section 31-118 executed and the original bill of assurance.
An acceptable storage device with the data in CAD compatible .DXF and/or .DWG format containing the state plane coordinates for all property boundary corners of plat (each phase), street centerline data as shown on the final plat. Storm drainage as-built information including pipe inverts, length of pipe, size of pipe, type of pipe, and type of inlets shall be provided in a separate .DXF and/or .DWG file and included on the submitted acceptable storage device.
The final plat shall be clearly and legibly drawn in black ink on suitable tracing material at the same scale and dimensions used for the approved preliminary plat. Upon approval and execution of the certificate of final plat approval, the owner's representative will file the plat for record at the circuit clerk's office and return a certified Mylar to the city within two (2) working days, unless another period of time is mutually agreed to by the owner's agent and city representative.
(b) The final plat shall indicate the following information:
(1) Name and address of owner of record and subdivider.
(2) Name of subdivision.
(3) Date of the plat, north point and graphic scale.
(4) Names of all streets.
(5) Boundary information of the tract shall be as follows:
a. Boundary lines shall be indicated by a heavy line.
b. Adjusted Arkansas State Plane Coordinates (north zone, NAD-83) shall be shown for all boundary corners and all corners of record utilized, along with a statement indicating the ratio error of closure of the field work.
c. Adjusted bearings and distances shall be shown on all boundary lines and ties to all corners of record utilized. Where boundary lines are curves, sufficient curve data shall be provided to establish or reestablish the curve. As a minimum, curve data for each curve shall consist of radius, arc distance, delta angle and chord bearing and distance. Where boundary lines are common with previously platted properties, record bearings and distances shall also be shown.
d. Accurate locations and adequate physical descriptions of all monuments shall be shown indicating size, type of material and construction thereof, and size and type of survey disk utilized. Where found monuments are replaced with more permanent monuments, such replacement shall be noted and a description of the type of found monument indicated.
(6) Streets and alleys within and abutting the subdivision, with street names indicated and showing the source of dedication.
(7) Street centerlines shall be shown with the following information provided:
a. Bearings and distances along all line segments.
b. Angles of intersection.
c. Curve data for all curves indicating the following:
1. Radius.
2. Length of tangents.
3. Delta angle.
4. Chord bearing and distance.
Sufficient geometric data shall be provided along all rights-of-way to produce a closed polygon figure within the bounds of the tract being platted.
(8) Source of title giving deed record book and page number or instrument number.
(9) Sufficient geometric data shall be provided along all lot lines (bearings and distances and/or angles) to produce a closed polygon figure for each lot, with chord bearings and distances and radii of rounded corners.
(10) Building setback lines with dimensions.
(11) Lot and block numbers.
(12) Easement, buffer strips and public service utility right-of-way lines giving dimensions, locations and purposes.
(13) Sufficient geometric data shall be provided to produce a closed polygon figure along with a description of any areas to be dedicated or reserved for public use or acquisition with the purpose indicated thereon; and of any areas to be reserved by deed covenant for common use of all property owners.
(14) Accurate locations and descriptions of all monuments.
(15) Key map where more than one sheet is required to present the plat, and in all instances final plats shall have a location map illustrating an area within a radius of one-half mile of the proposed subdivision at a scale of one (1) inch to two thousand (2,000) feet. The drawing shall generally locate arterial streets, highways, section lines, railroads, schools, parks and other significant community facilities, plus, location within a developing plat.
(16) Location of tract by metes and bounds legal description giving acreage to the nearest one-thousandth of an acre.
(17) Any area or lot which may be prone to local flooding shall have the lowest allowable finished floor elevation indicated on the final plat. This elevation shall be compared to the one (1) in one hundred-year flood elevation shown on the flood insurance study or, if not available, any other applicable study in which the one (1) in one hundred-year flood elevation is depicted. The department of planning and development shall review an approved compliance with chapter 8, article IV.
(18) Storm drainage as-built information including pipe inverts, length of pipe, size of pipe, type of pipe, and type of inlets.
(c) Copies of all survey calculations and field notes shall be submitted for review when requested. When errors are suspected, the planning commission may cause a professional surveyor to check the final plat for correctness. Certification of approval of water supply and sanitary sewage disposal by the appropriate agency, when not connected to the municipal system, shall be submitted.
(Code 1961, § 37-19(a)—(c); Ord. No. 15,929, § 1(h—k), 9-4-90; Ord. No. 16,341, § 1(tt), 1-19-93; Ord. No. 16,861, § 1(tt), (vv), 3-21-95; Ord. No. 17,697, § 3d, 3-17-98; Ord. No. 18,031, § 1(k)—(m), 6-1-99; Ord. No. 20,326, § 1(c), 9-21-10; Ord. No. 21,867, § 1, 5-19-20)