33.150.210 Height

A. Purpose. Maximum height limits work with other development standards to control the overall scale of buildings. The height limits in the CI zones allow for urban scale development that generally reflects the intent of each zone. Height limits adjacent to residential and mixed use areas preserve light, air, and the potential for privacy in the adjacent zones, and discourage buildings that visually dominate adjacent development. B. Maximum height. The maximum height standards for all structures are stated in Table 150-2, or are shown on Maps 150-1 through 150-4. Maximum height is reduced adjacent to certain zones as described in Subsection C. The maximum heights shown on Maps 150-1 through 150-4 supersede the maximum height standards in Table 150-2 and Subsection C. Exceptions to all the maximum height standards are stated in Subsection E. C. Reduced maximum height. Maximum height is reduced adjacent to certain zones. 1. In the CI1 zone, maximum height is reduced as follows. a. On the portion of the site within 60 feet of a lot line abutting or across the street from a site zoned OS or RF through R2.5, the maximum height is 30 feet. See Figure 150-1. b. On the portion of the site within 40 feet of a lot line abutting or across the street from a site zoned RM1 through RMP or commercial/mixed use zones the maximum height is 45 feet. See Figure 150-2. 2. CI2 zone. a. Maximum height is reduced on sites in the CI2 zone that abut or are across the street from a site zoned OS, or RF through R2.5 as follows: (1) On the portion of the site within 60 feet of a lot line abutting or across the street from a site zoned OS, or RF through R2.5, the maximum height is 30 feet. See Figure 150-1. (2) On the portion of the site that is more than 60 feet but within 130 feet of a lot line abutting or across the street from a site zoned OS, or RF through R2.5, the maximum height is 75 feet. See Figure 150-1. b. Maximum height is reduced on sites in the CI2 zone that abut or are across the street from a site zoned RM1 through RMP, or commercial/mixed use zones as follows: (1) On the portion of the site within 40 feet of a lot line abutting or across the street from a site zoned RM1 through RMP, or commercial/mixed use zones, the maximum height is 45 feet. See Figure 150-2. (2) On the portion of the site more than 40 feet but within 110 feet of a lot line abutting or across the street from a site zoned RM1 through RMP, or commercial/mixed use zones, the maximum height is 75 feet. See Figure 150-2. Figure 150-1

![](https://figures.74-208-44-221.nip.io/portland/20261114/76eddd2e90e8c3791bafe26243e848c30dfdcce767dc8fde8c3e8875f9612d7e.png)

![Figure 150-1](https://figures.74-208-44-221.nip.io/portland/20261114/eae5686775d2d6939038c03f07af54b94f0507985f5da67d7824f434fece711d.png)

![](https://figures.74-208-44-221.nip.io/portland/20261114/67c198d56735cc08876626eb45b8827d6a459b765c1000f36138197f88f05e3c.png)

![](https://figures.74-208-44-221.nip.io/portland/20261114/d2ca809d64fe802078a661629d6728c637c75be48ea20586172b3a433e7239da.png)

D. Exceptions 1. Chimneys, flag poles, satellite receiving dishes, and other items similar with a width, depth, or diameter of 5 feet or less may extend 10 feet above the height limit, or 5 feet above the highest point of the roof, whichever is greater. If they are greater than 5 feet in width, depth, or diameter, they are subject to the height limit. 2. Parapets and rooftop railings may extend 4 feet above the height limit. 3. Rooftop mechanical equipment, including required screening, and stairwell enclosures that provide rooftop access may extend above the height limit as follows, provided that the equipment and enclosures are set back at least 15 feet from all roof edges on street facing facades: a. Elevator mechanical equipment may extend up to 16 feet above the height limit; and b. Other mechanical equipment and stairwell enclosures that cumulatively cover no more than 10 percent of the roof area may extend up to 10 feet above the height limit. 4. Antennas, utility power poles, and public safety facilities are exempt from the height limit. 5. Small wind turbines are subject to the standards of Chapter 33.299. Roof mounted solar panels are not included in height calculations, any may exceed the maximum height limit if the following are met: a. For flat roofs or the horizontal portion of mansard roofs, they may extend up to 5 feet above the top of the highest point of the roof. b. For pitched, hipped, or gambrel roofs, they must be mounted no more than 12 inches from the surface of the roof at any point, and may not extend above the ridgeline of the roof. The 12 inches is measured from the upper side of the solar panel. 6. Towers and spires with a footprint of 200 square feet or less may exceed the height limit, but still must comply with the setback standard. Table 150-2 Summary of Development Standards in Campus Institutional Zones

![](https://figures.74-208-44-221.nip.io/portland/20261114/9954691ce2a36c7fe66da52fa945c0a09505e8df024935fb2289a1bfd08bf7f5.png)

Notes: [1] For Colleges and Medical Centers, the entire CI zone is treated as one site regardless of ownership. In this case, FAR is calculated based on the total square footage of the parcels within the zone rather than for each individual parcel, and setbacks, building length, facade articulation, ground floor windows and transit street main entrance regulations are measured from, or only apply to, the perimeter of the zone. [2] Maximum FAR within the Legacy Good Samaritan Hospital and Health Center campus boundary shown on Map 150-3 is 3.7 to 1, and is 4.5 to 1 with inclusionary housing bonus. [3] Maximum FAR within the PCC Sylvania campus boundary shown on Map 150-5 is .75 to 1, and is 1 to 1 with inclusionary housing bonus. [4] Heights reduced on sites that are across the street from, or adjacent to, certain zones. See 33.150.210.C. [5] For frontages where the maximum building setback applies, there is no minimum setback.