§ 31-52 — IRC CHAPTER 3 BUILDING PLANNING - amendments
Scottsdale Revised Code (Supp. No. 80: codified through Ordinance No. 4681, adopted July 1, 2025) · Scottsdale Revised Code § 31-52
Corpus is an independent public-information project, not the official City of Scottsdale website. Stable reference: corpuslaw.us/code/9b9149ac-5ea4-4ddc-b001-85376ae00fda
Sec. 31-52. - IRC CHAPTER 3 BUILDING PLANNING - amendments.
Only the following portions of CHAPTER 3 BUILDING PLANNING, are amended: (a) Table R301.2, CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA, is amended to read as follows: TABLE R301.2 CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA Ground snow load | 0 Wind speed | 105 mph Topographic effects | No Special wind region | No Windborne debris zone | No Seismic design category: | B Weathering | Negligible Frost line depth | Final grade Termite | Moderate Ice barrier underlayment required | No Flood hazard | See Scottsdale Revised Code, Chapter 37 Air freezing index | 0 Mean annual temperature | 71.2°F MANUAL J DESIGN CRITERIA Elevation: | 1,473 feet Latitude: | 33.62 N Altitude correction factor | 0.97 Daily range | High (H) Mean coincident wet bulb | 70°F Indoor summer design relative humidity | 45% Indoor summer design dry-bulb temperature: | Minimum of 75°F Indoor winter design dry-bulb temperature: | Maximum of 72°F Outdoor summer design dry-bulb temperature: | 107°F Outdoor winter design dry-bulb temperature: | 37°F Heating temperature difference | 20.6°F Cooling temperature difference | 20.1°F (b) Section R303.3, Bathrooms, is amended to read as follows: R303.3 Bathrooms. Bathrooms, water closet compartments and other similar rooms shall be provided with a permanently installed lighting fixture and local exhaust fan. The minimum local exhaust rates shall be determined in accordance with Section M1505. Exhaust air from the space shall be exhausted directly to the outdoors. Exception: A local exhaust fan system shall not be required for bathrooms and water closet compartments located in an unconditioned space with an openable window area of not less than 1.5 square feet (0.15 m 2 ). R303.3.1 Exhaust fan controls. Exhaust fans shall be switched separately from lighting systems. Except where functioning as a component of a whole house ventilation system, exhaust fans in bathrooms with a shower or tub shall be provided with a delay timer or humidity/condensation control switch. (c) Section R303.10, Required heating, is retitled, and amended to read as follows: R303.10 Required heating and cooling. Dwellings shall be provided with heating per Section R303.10.1 and cooling per Section R303.10.2. R303.10.1 Heating. Heating facilities shall be provided, capable of maintaining a room temperature of not less than 68°F (20°C) in all habitable rooms, bathrooms, and toilet rooms, based on the winter design temperature of 34°F (01°C) for Phoenix, per Appendix D of the International Plumbing Code. Cooking appliances and portable space heaters shall not be used to achieve compliance with this section. Exception: Heating systems are not required for interior spaces where the primary purpose of the space is not associated with human comfort. R303.10.2 Cooling. Cooling facilities shall be provided, capable of maintaining room temperature of not more than 85°F (29°C) in all habitable rooms, bathrooms and toilet rooms, based on the summer design temperature of 107°F (42°C) for Phoenix, per Appendix D of the International Plumbing Code. Exception: Cooling systems are not required for interior spaces where the primary purpose of the space is not associated with human comfort. (d) Section R313, Automatic Fire Sprinkler Systems, is amended to read as follows: R313 Automatic Fire Sprinkler Systems. See Scottsdale Revised Code, Chapter 36, for automatic fire sprinkler system requirements.
(Ord. No. 4575, § 1(Res. No. 12499, § 1(Exh. A)), 12-6-22)
Ask a question about Scottsdale law
Corpus searches the Scottsdale sections it holds and shows the ones that match, with their citations. Free, no sign-in.
