§ 49-825 — Plastic pipe and fittings for soil, waste and vents
Omaha Municipal Code (Supp. No. 100, Update 2: codified through Ordinance No. 44760, enacted August 4, 2026) · Omaha Municipal Code § 49-825
Corpus is an independent public-information project, not the official City of Omaha website. Stable reference: corpuslaw.us/code/9bd29940-4401-4cd9-a962-4cad95b0d9f8
Sec. 49-825. - Plastic pipe and fittings for soil, waste and vents.
ABS and PVC shall not be co-mingled, inserted or mixed with other materials. When connecting to existing plastic systems, all pipe and fittings shall be the same material as the existing system. Plastic pipe installations shall comply with the following standards: (a) Polyvinyl chloride (PVC). (1) Shall be schedule 40 (IPS). (2) Shall meet ASTM Standard D2665, F891. (3) Solvent cement shall meet ASTM D2564. (4) Primers shall be clear and meet ASTM F656. (5) All solvent cement joints shall be made according to ASTM D2855. (6) Shall not be installed in return air plenums except in single-family dwellings. (b) Acrylonitrile-butadiene-styrene (ABS). (1) Shall be schedule 40 (IPS). (2) Shall meet ASTM Standard D2661 or F628 or F1488. (3) Cement shall meet ASTM D2235. (4) All cement joints shall be made according to ASTM D2661 and F402. (5) Shall not be installed in return air plenums except in single-family dwellings. (c) Storage and protection of plastic. (1) Pipe and fittings should not be stored in direct sunlight. (2) Pipe shall be stored in such a manner as to prevent sagging or bending. (3) Plumbing vents exposed to sunlight shall be protected by a water based synthetic paint. (4) Pipe passing through wood studs or plates shall be protected from puncture by a steel plate at least one-sixteenth inch thick. (d) Thermal expansion. (1) Support pipe according to subsection (f) below, but do not rigidly restrain the pipe at branches or change of direction. (2) Pipes shall not be rigidly anchored in walls. All holes shall be adequately sized to allow for free movement. (3) Tables 49-825(d)(3)-1 and 49-825(d)(3)-2 below are provided to show examples of thermal expansion. Temperatures listed are the maximum expected operating range. Consult the manufacturer's data for the material to be installed. _____ TABLE 49-825(d)(3)-1 Thermal Expansion for PVC (Inches) Temperature Range Length (feet) | 40F | 50F | 60F | 70F | 80F | 90F | 100F 20 | 0.278 | 0.348 | 0.418 | 0.487 | 0.557 | 0.626 | 0.696 40 | 0.557 | 0.696 | 0.835 | 0.974 | 1.114 | 1.235 | 1.392 60 | 0.835 | 1.044 | 1.253 | 1.462 | 1.670 | 1.879 | 2.088 80 | 1.134 | 1.392 | 1.670 | 1.949 | 2.227 | 2.506 | 2.784 100 | 1.392 | 1.740 | 2.088 | 2.436 | 2.784 | 3.132 | 3.480 TABLE 49-825(d)(3)-2 Thermal Expansion for ABS (Inches) Temperature Range Length (feet) | 40F | 50F | 60F | 70F | 80F | 90F | 100F 20 | 0.536 | 0.670 | 0.804 | 0.938 | 1.072 | 1.206 | 1.340 40 | 1.070 | 1.340 | 1.610 | 1.880 | 2.050 | 2.420 | 2.690 60 | 1.609 | 2.010 | 2.410 | 2.820 | 3.220 | 3.620 | 4.020 80 | 2.143 | 2.680 | 3.220 | 3.760 | 4.290 | 4.830 | 5.360 100 | 2.680 | 3.350 | 4.020 | 4.700 | 5.360 | 6.030 | 6.700 _____ (e) Below ground installation. (1) Pipe shall be secured to the bottom of the trench at no more than eight-foot intervals and backfilled to the pipe's spring line for ground work inspection. (2) Bedding material may consist of dirt, sand, gravel, or crushed rock. Backfill and bedding material shall not exceed one and one-half inches in diameter. No frozen fill material is acceptable. (3) Pipe shall not be installed directly on mud, muck, standing water, or frozen ground. If such an unstable condition exists, the trench shall be over-excavated a minimum of six inches and bedding material as listed above other than dirt shall be placed in the trench to support the entire length of the pipe. (4) Provide a minimum one-half inch clearance around the entire outer circumference of the pipe or fitting when penetrating concrete. Space between the pipe and concrete shall be sealed, insulated or caulked. Exceptions are floor drains and closet bends. (5) The pipe shall be positioned in the trench so that the identification markings on the pipe are readily visible for inspection. (6) The minimum size waste, soil, or vent below grade shall be two inches (IPS). (7) No vent type fittings or short turn elbows will be allowed below grade except that short turn 90's will be allowed for closet bends. (8) Threaded fittings shall not be used. (f) Support above ground. (1) Horizontal: Plastic pipe shall be supported at no more than four-foot intervals. (See Figure 49-825(f)(1).) (2) Vertical: Plastic pipe two inches and less shall be supported at no more than four-foot intervals. Sizes above two inches in diameter shall be supported at no more than eight-foot intervals. (See Figure 49-825(f)(2))
(Ord. No. 40524, § 1, 10-20-15; Ord. No. 42654, § 30, 8-13-21)
Ask a question about Omaha law
Corpus searches the Omaha sections it holds and shows the ones that match, with their citations. Free, no sign-in.