San Antonio City Code § 3-231 Landing facilities—Design criteria.
Sec. 3-231. - Landing facilities—Design criteria.
(a) [General criteria.] The size requirements and overall design criteria of heliport and helistop facilities will vary dependent upon the proposed use and the size of the largest helicopter anticipated to use the facility. Therefore, the design criteria set forth in Federal Aviation Administration Advisory Circular No. 150/5390-2A "Heliport Design," or subsequent revisions to this advisory circular shall be utilized when preparing the plans and specifications for a proposed heliport or helistop.
(b) Special design criteria elevated facilities (roof-top)
(1) Where facilities are built on elevated structures the strength of the contact surface should be great enough to withstand at least three-quarters gross weight of the helicopter on one (1) square foot of that surface. The structural requirement above shall be certified by a licensed engineer prior to issuance of certificate of occupancy. All structures shall meet the requirements of the Uniform Building Code.
(2) Two (2) or more exits or fire escapes, or both, as specified by the city's Building Code, as amended, shall be provided from any elevated facilities (roof-top). They shall be located as required by the Uniform Building Code.
(Ord. No. 63553, 8-28-86; Ord. No. 84181, 5-30-96)